В 2019 году я занимался программированием и наладкой крупного объекта (чиллеры, котлы отопления, вентиляция) на базе CX9020 и панелей Weintek, имея только неделю обучения по работе с этим оборудованием и никакого практического опыта. Приходилось иногда не спать ночами, чтобы в спокойной обстановке обдумать решение какой-либо проблемы. В итоге - объект был закончен и сдан в эксплуатацию. Присоединяюсь к словам Якоба - никогда не сдавайтесь, уважаемые инженеры, и вас ждет успех!)
Love the video! Hope you keep uploading. Nice to see a consistent PLC RU-vidr, very rare compared to traditional type of programming. Hope me becoming a member helps a tiny bit to inspire you to keep going. Greetings from a young Automation Engineer in southern Skåne
Hej! Kul att du gillade min video. Absolut, jag har planer för en hel del videos så räkna med att det kommer komma en del framöver. Tack så hemskt mycket för att du blivit kanalmedlem, uppskattas!
@@JakobSagatowski As far as you have been able to test so far, do you consider this plc a reliable system? It would be interesting to try it with electronic axes. Great work BTW 😉
Thanx for this, Jakob. I need to dig out the portenta pro from the drawer and play with it. This should be possible to do with MQTT as well, dont you think?
Hi JakobSagatowski! Thank you for the amazing video, it has been very helpful, given there is no documentation and I am completely new to PLC. Unfortunetly, I get the same error as you (esi = -300) but rebooting the device just generates new error (esi = -324). I was wondering whether you can advise me on this error and how to fix it? I used your code letter for letter.
The modbus organization is using "client-server" to describe Modbus communications, characterized by communication between client device(s), previously called master(s), which initiates communication and makes requests of server device(s), previously called slave(s), which process requests and return an appropriate response (or error message).
Hello, do you hear about OpenPlC? (NOT PLCOpen) The Editor is similar to the Arduino One and you can use it for much more Boards. Would be nice if you can check it and make a video. Especially what i couldnt resolve there is to import FB_Librarys there like the OSCAT Library. Can you check if OSCAT Library for the ARDUINO PLC IDE is working?
Congrats, very nice video!! Can you please do the same by communicating by Modbus TCP between Arduino Opta and Portenta Machine Control? It would be amazing. Thank you for sharing your wisdom on these videos.
Hi I'm from India I'm beginner to beckhoff sir previously had worked in Delta plc, Mitsubishi plc.. Now I had involved in new project in beckhoff plc now I'm facing some issues pervious they displayed the teency lc data in beckhoff visualization thought serial usb now it's not display the data
I really disliked the arduino portenta machine control. It was a pain in the ass to even connect to it, then the analog input readings were really inaccurate. I ended up returning and buying some Click PLC stuff