Тёмный

Beuler BU-509TD Time Delay Relay -  

QMV Fast Tech
Подписаться 1,2 тыс.
Просмотров 21 тыс.
50% 1

Beuler BU-509TD 12 VDC Automotive 5-Pin SPDT Time Delay Relay with adjustable timing
Delay-Off
www.qualitymob...
#timedelayrelay #qmvfasttech #12vrelay
Standard automotive style relay
Adjustable time delay 2 seconds to 3 minutes with internal potentiometer
20 amp / 30 amp rated contacts
SPDT - Single pole Dual throw
Low 1volt (1k Ohm) trigger voltage
Unit includes: 12 volt time delay relay
QMV TDR12V1 12 VDC SPDT 1 - 10 Seconds Adjustable On Time Delay Relay
Visit www.QualityMobi... for all of your car audio and video needs!
Get your QMV Merch today!
teespring.com/...
#qualitymobilevideo #installations #caraudio
Instagram: @qualitymobilevideo
Twitter: @qualitymobilevi
Facebook: / qualitymobilevideocom-...

Опубликовано:

 

16 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 42   
@luisgordillo1695
@luisgordillo1695 4 года назад
thinking of using this on my stereo system, want to keep my radio from rebooting while cranking the truck on. sure this awesome relay will last long.
@sushilthakur94
@sushilthakur94 2 года назад
Useful
@Electronzap
@Electronzap 8 месяцев назад
Cool component.
@dodgechallenger2008
@dodgechallenger2008 3 года назад
Is it possible to get an off delay relay that works off of a ground wire trigger vs the hot wire trigger?
@TruckDriver326
@TruckDriver326 Год назад
I need the same thing. I need a crush control to reach 1000 RPM after the remote start. I will use a negative trunk trigger to activate the relay. I need the relay to send negative to the crush control button for 5 seconds so the RPM go to 1000 and then turns off the relay.
@Aizo.K
@Aizo.K 5 месяцев назад
Hello, may I use it to control the glow plugs of the diesel engine instead of the timer / controller
@deadspeed6679
@deadspeed6679 16 дней назад
Is this LED headlight compatible?
@scottkrieman8108
@scottkrieman8108 3 месяца назад
I have 4 five pin 12 volt DC relays hooked together along with two limit switches and a push button momentary switch that runs a motor. I push the momentary switch that starts the motor moving an arm off the first limit switch then goes to the second limit switch and immediately reverses the motor to make the arm go back to the first limit switch and stop. I need the motor to stop for about two seconds when the arm hits the second reversing limit switch then the arm needs to travel back to the first limit switch and stop. Can you tell me what kind of time delay relay to use? I need help to know how to build this circuit I am not very knowledgeable about electronics.
@ahmadnurhasybi9918
@ahmadnurhasybi9918 2 месяца назад
Is it work for 6 VDC and 4 Amp source?
@_illtal
@_illtal 4 года назад
Can a ground be passed through the NC contact? If so how would I go about doing that?
@stanzhubrak818
@stanzhubrak818 3 года назад
did you get your answer I have the same Q. I have Sniper EFI unit that uses ground trigger
@_illtal
@_illtal 3 года назад
@@stanzhubrak818 yes I found out that it is possible. It you can wire it to send to ground . There is a diagram of this setup out on the web.
@sushilthakur94
@sushilthakur94 2 года назад
It is possible but it that scenario wire 30 i.e. constant +ve must be replaced with constant -ve
@TruckDriver326
@TruckDriver326 Год назад
It looks like I have to used 2 regular relays with this to get a negative out to run up the curse control. regular relay negative convert over to 12v to trigger the beuler bu-509td this will go into another regular relay for ground output to my Cruise control to get my 3 seconds of ground output.
@DIYStangsandFreedom
@DIYStangsandFreedom 9 месяцев назад
Is there a version where the 86 and 85 are flipped. I would like to use this as a modified led flasher but my car ground is on the left side and trigger on the right side
@GK-Greece
@GK-Greece 7 месяцев назад
I wanna a closed relay,when signal come it open with delay and close the power to source But when the trigger signal stop, is it closed immediately or have delay ?
@Milner62
@Milner62 Год назад
Does that company make a relay that when it sees power it will only stay on a set period of time before shutting off even if it maintains power? Project I am working on I am trying to add a "wait to start" light but I need it where when the key is turned on it will power up the relay for 2 to 3 seconds then switch off. Only other option is to jumper off the seat belt light but I dont want to do that unless I absolutely have to.
@PeterFeltersnatch852
@PeterFeltersnatch852 5 лет назад
This is a great product but what do a lot of people use it for I'm racking my brain hear what do you need a timer for? Please explain quality mobile....
@QMVFastTech
@QMVFastTech 5 лет назад
It's basically to control an event based on time in electrical devices/systems. This relay is useful for using a decorative momentary switch to trigger a device. Another use is to have your audio or lighting system stay on for up to three minutes after you turn your vehicle off.
@MrJoey1570
@MrJoey1570 4 года назад
Cherokee xj owner here using it to run the electric radiator cooling fan after motor is shut off to cool fuel injectors and fuel rail to stop vapor lock
@theoutlaw2395
@theoutlaw2395 4 года назад
I'm going to use it for my exhaust cutouts. When I push the cutout button, I want the relay to keep power to the cutout motor for about 5 seconds to fully open or close the cutouts so I don't have to keep holding the Open or Close button and counting to 5.
@christos8189
@christos8189 2 года назад
How could I make this work as a delay off with a trigger that is a toggle but stays on? I am hoping to have multiple cooling components on one toggle but have some devices delay off after time allowance even though trigger is still “high”. Is that too much logic for a relay setup? I am idealizing a relay that times out after the trigger is engaged no matter the state and resets timer on a low state. Thanks for help
@Dougrun
@Dougrun 11 месяцев назад
I want it to keep my power windows powered for 30 seconds after i take out the ignition. I have power to 30, ignition to 86, ground to 85 and 87 to the power windows, but the relay turns off immediately, even with max adjustment on top. Any clues??
@sushilthakur94
@sushilthakur94 2 года назад
🙌🏼🙌🏼🙌🏼
@TruckDriver326
@TruckDriver326 Год назад
I need the same thing. I need a crush control to reach 1000 RPM after the remote start. I will use a negative trunk trigger to activate the relay. I need the relay to send negative to the crush control button for 5 seconds so the RPM go to 1000 and then turns off the relay.
@gtdodgeviper
@gtdodgeviper Месяц назад
$8 for shipping and 23 for the relay? No way.
@bobbafett1971
@bobbafett1971 10 месяцев назад
So I went to purchase this...put in my payment information then went to 404 page not found. I cannot get to we website on any devices. Seems like a scam link to get card info. Any ideas?
@mariocalbasa882
@mariocalbasa882 Год назад
How much sir
@Evrenthewrencher
@Evrenthewrencher 4 года назад
Does this work with ground trigger set up for my cooling thermo switch?
@treetop5752
@treetop5752 3 года назад
Reverse this one OR GET HELLA #
@jericflores9648
@jericflores9648 3 года назад
is there 24volt version?
@QMVFastTech
@QMVFastTech 3 года назад
Jeric, There is not one yet but it is in the works.
@KoiAquaponics
@KoiAquaponics 5 лет назад
If I have a 12v switch to trigger this relay and the trigger turns off immediately, there's no way for this relay to activate's delay off function? Because in the video you said it needs a constant trigger voltage to switch to delay off, otherwise it's delay on by default?
@sushilthakur94
@sushilthakur94 2 года назад
You can use capacitors for that. I'm using 6*4700uf capacitor for making light connection in my car
@HeritageExplorer
@HeritageExplorer 4 года назад
Can this work to provide power for periods less than one second?
@QMVFastTech
@QMVFastTech 4 года назад
Only 0:02 to 3:00
@mowgliclark
@mowgliclark 5 лет назад
Beuler BU510TD 12 VDC = where can I find/buy this item?
@QMVFastTech
@QMVFastTech 5 лет назад
We always put the links in the bio! www.qualitymobilevideo.com/bu509td.html
@dr.narasimhareddy4726
@dr.narasimhareddy4726 4 года назад
I believe this relay can be used for delay on as well by connecting the load to NC terminal. If yes then why BU510TD? Can this be had with a digital timer where we can see and set the exact number of seconds for which this works once triggered.
@jethro9341
@jethro9341 4 года назад
I need one that will stay on for more than 3 minutes.
@treetop5752
@treetop5752 3 года назад
EBAY
@jethro9341
@jethro9341 3 года назад
@@treetop5752 not finding one. You got a link?
Далее
Mini bag sealer
00:58
Просмотров 5 млн
On delay timing control circuits
4:48
Просмотров 37 тыс.
Do you have turn on or off POP watch this
7:03
Просмотров 15 тыс.
timer off delay CARA MEMBUAT DILAY OF LAMPU
11:28
Просмотров 55 тыс.