On basic systems using desi UPS or a non complicated inverter with solar, I use a simple 24 hour timer using 2 hour intervals or more ( between depending on my load) wapda charging and switching off.
Thanks for your help. I have adjusted according to your suggestion and satisfied. It was always a problem for me because batteries were always charging and discharging even at night. Thanks again
OSO works fine if batteries are in good condition. If batteries are weak, they will drain during the night with almost very low backup in case of need. Good informative video.
Hi, What are the best settings to charge/discharge the batteries if load-shedding is not happening? Load = SBU & Charging = CSO ? are these two settings are recommended ?
Sir.mah Nowsher kpk sah mary pass Maxpower 5.2 kw infni inverter hay is may konsa options hay joh battery voltage ( for example full point 60v hay or may nah 50v point per ho ker wapda pah beypass ho jay ) or per 50v charge ho kar wapda wapis cut off jo jay yah options hay magier muj say boll ga yah
Hamary han raat 8 bjy aur raat 4 bjli jati hy siraf 2 ganty. Main ny charging OSO pr rakhi hy ur out put source priority main timer setting ki hy. Subh 6 sy shaam 5 bjy tak SUB chalti hy aur 5 bajty hi inverter automatically USB pr chala jata hy subh 6 bjy tak. Aur phir subh 6 bjy automatically wapas SUB par aa ata hy. Aur jab badal hoty hain to jb battery ki voltage 23.5 tak aa jati hy to load automatically USB pr chala jata hy aur phir solar battery ko charge karta hy aur jb battery ki voltage phir sy 25.5 ta barh jati hy to dobara SUB pr shift ho jata hy. Mery bijli ki bill main 75% tak kami ho gai hy.
In evening when inverter shift to battery in SBU load is on via battery after battery load is shifted to utility then charging of battery starts by wapda as solar is not available , when battery is charged till its full capacity load is again shifted to battery and power consumption is zero by wapda , in this way electricity is saved by hybrid inverter , How you claim to save electricity by your logic ? Did you calculated the units that are consumed by charging batteries ? Are they less when load is shifted to batteries after charging ?
اسلام عليكم ورحمة الله وبركاته بھائی جان اللہ آپ کو خوش رکھے اور سلامت آپ کا بہت بہت شکریہ زبردست سعودی عرب مدینہ منورہ سے میرے پاس 6 پلیٹ 250 واٹس کی لگی ہوئی ان کو کس طرہ جوڑوں بہت بہت شکریہ
Bisab yah ap inverter per depend karti hay liken ap in koh sires mah laglay 3 panel 1 sires koh ²set kar naya hay for example { [((-))] [+] }{ [-] [+] }{ [-] (( [+] )) } yah ak sires hay asta rah ap nay ²set koh parlel kar kay in verter koh day nay hayak set kay [-] piont koh [-] sa contact karnay hay or [+] piont koh[+]sa contact karnay hay ((piont yah wier ))
Mai subscriber Hu aapka jis inverter ki aapne video banayi ha ismai option sub ha baaki jo isse neeche waale models hain usmai sub nai ha tou uski battery kaise bachayen. Apne jawab nai Dena humain Pata ha
Assalam o alekum sir ji, Mera ilaqa bohat garam hai yahan per m bijli Ka bill ziada pay ni Ker sakta to kon c splite DC inverter loon jo cooling bhi achi kry aur soler per bhi chaly ager wapda per chalao to ampare Kam kharch hoon plz reply
Nice infrn. Sir I hav phonix tubler batries 1800 for 3.2 inverter . let me know about 2 no setting. How much amper is good.more I need batries temp thermometer. Is it avail at ewalstore
Hello brother . Yar mere pas chota sa solar system laga ha ghar me ....... 300 W k solar panel hai and battery 12 V/120 AH ki hai ....... Is se battery pori charge huti nahi .... Load only 1 Fan and 1 bulb hai ......... Me utility se charge karna chahta hun battery ko ....... Ab me charger kesey set karon battery k sath ???? Battery k sath wires/connections hain usey hata k charge karon and then dubara lagaon ya koi aur method hai ????
Wapda si mukammal ninjad k liyi 5 kw mi raat k liyi 8 hour chalana hi to 16 panel k saat kitni batri lagai??? R yi batai ki sardiyo mi yi solar system over all kamyab hi kya?
Bhai mery ghr 1kv ka system lgaya hy jis ma ups KY Sath mppt lgaya hy ma ny pochna ye tha KY ups ka Sath sirf phase ki wire connect Hy or neutral direct Hy to is sy meter pr load Daly ga ya ni?
Hy, in this video the wapda meter was detecting 10th part of the current, in my house if wapda is turned on the complete load shifts to wapda and the fifth reading on meter is almost equal to the load... For example if load is 900watts it shows 0.9KW... can you tell what could be the possible cause?
Well done baita, May Allah bless you and your family. You have solved my problem. I want to attach Bluetooth device with my Aerox 3.2 Inverex inverter, can you guide me from where I can get this device, It is not available at Hall road Lahore , it will be highly appreciated. Thanks.
Din k time pey agher hum is ki setting sub rakhein to bill mein koi frq nahi ata balkey olta bill zyda aey ga is ley subha 7 sey sham 4 bajey tak is ki setting sbu honey cahey or sham 4 sey subha 6 bajey tak setting sub honey chahey k jo k inverters mein momkin ha boht easy ha ye settings krney sey life asan ho jati ha
Aoa, bhi mere pass 175 amp ki battery hai 150 x 3 panel hai and luminous ka ups hai. Mgar solar se battery thk charg nhi horahi ar jaba electricity se ups k zarye charg krte hai bill b zyada ata hai... please is bare me bataye
AoA boss apse aik issue discuss krna tha m ny 3.2 k solar lga rkha hy. m ny aik application download ki hy power watch m jb check krta hy to application m to battery voltage 24.6 show krta hy r battery capacity 25% show krta hy jb k battery check kwae to gravity sahi hy kya battery m msla hy ya solar m
Bhhai Kya ye inverter battery full charge karnay par charging cut off Kar deta hay chahay solar par charging ho ya wapda pay please is par bhi aik video banaye
walekum assalam. will you tell me, if i hang four lights of about 200 watts each over four solar panel, will those lights provide enough energy to inverter and will give lights, as in the day, and will also charge the battereies.
Output = SUB per set hai aur Battery charging = OSO, per sham hoty inverter pehly battery use krta hai uske bad utilities per convert hota hai, aisa q hai?
Solar + wapda same time IN inverter on hona aur load run na krna pr wapda meter reverse light on krta ha. Jbka load run krna pr wapda meter reverse light off ho jati ha. Kindly explain
Assalam o Alaikum, ap se ek baat clear krni jisko mene boht search kia par koi clear answer ni mil ska. Currently mere pas ghr pe UPS lga hua he aur uski output neutral common he wapda grid k sath. agr me 1 ya 1.5KW solar inverter ko UPS ki jagah pe lgaun to kia muje grid ki neutral se iski neutral ko isolate krna pare ga ya common ki chalaun. aur agr common neutral hi chalaun to kia grid meter phir bhi extra consumption krta rahe ga common neutral ki wajah se ? Is baat ka response de den please, JazakAllah Salman
Good video lakin meray khiyal maim cso settings best hai jis main din ko solar par aur rat ko utility par charging hogi. Is say batteries sirf backup ky liay istimal hon gi
Question: when SOL option is selected, priority is solar then battery then utility depends upon load consumption and pv input. When day about to end or solar ati hay low voltage mai tu wo sham k time battery use hoti rehti hay...tu matlb sham ko load battery say hi chal raha hay due to low pv input is say battery khatam ho jati hay phr utility say hi charge karna parti hay is ka kia karin 🤔
Mere homage k inverter ma load k option ma sbu option hai jis ka matlab hai solar battery and utility.. Kia ye solar utility and battery hosakta hai. Agar han to kese hoga.
Assalam o Alaikum ! First of all I m very thankful to you for sharing such informative videos and keep sharing these videos. I have installed INVEREX solar inverter 3.2 KW. It 's fans are running continuously i mean inverter is not tripping. what is the problem ?
Salam Bhai... Meine b yehi Option 0s0 select kiya hai... But raat k time jb light Waps Ajati Hai... to Heavy Load On Nhi Hota.... Kiya Reason Ho sakta Hai Sir... Jb k Bypass Option b On Hai...Plzzzz Help
brother smart load managment k barey mein batein. kia ese inverters available hain pakistan mein jin se din k waqt khud bakhood inverter load manage kerta rahey k ager solar puri power na mil rahi ho tou remaining amount jo hai woh wapda sey ley aur ager solar sey full power a rahi ho tou khud bakhud sirf solar ko use kerey for consumption as well as for battery charging.
ap ne to bari asani se keh dia k sham ko wapda se battery charge nhi karni, jis jaga par 1 ghanta bijli hoti ha aur 1 ghanta nhi hoti, wahan par agar battery wapda se charge na karin to discharge ho jain gi. Means aise jagho par solar plant failure ha aur paise barbad krne wali bat ha
dont drain the battery completely ........ leave the juice for backup as, discharging the battery with no special use and then charging it with wapda is just a waste of a cycle ........ this will reduce battery life ..... instead, drain the battery to an extent that in case of backup it can provide that easily ....
Brother agr app ko Amp zeada required hein to perala mein theek by if volt ya watts zeada required hein to series mein theek hy Mery pass 1.2 erox chal raha hy 300 Wali 4 plates hein Mera 1tone Haier ka new model DC device wala bhe es pe chalta hy inverter mood pay
Bro! Usually mai bhi yehi karta hun SNU pe kar deta hoon lekin yar humare yahan load shedding bata ke nahi hoti😂 uss surat maj kya kiya jaye? Yeh bhi bata den? 😂