Тёмный

BOLT TENSION and Tension at Non-Permanent Joints in Just Over 10 MINUTES! 

Less Boring Lectures
Подписаться 72 тыс.
Просмотров 59 тыс.
50% 1

Опубликовано:

 

13 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 23   
@vanzz3863
@vanzz3863 5 месяцев назад
Man, props to the great editing and explanation of this topic! I’ve seen PAID courses with way less quality than your video Keep up the amazing work and I hope I can keep on watching your videos You just earned a new sub 😎
@forsakenV12
@forsakenV12 2 года назад
My goodness.. your tutorial is awesome ! Thank you !
@ianpemberton-f9p
@ianpemberton-f9p 10 месяцев назад
Excellent clear explanations.
@prashantbisht9884
@prashantbisht9884 3 года назад
Thank u very much ... Now i can solve all the gate questions
@LessBoringLectures
@LessBoringLectures 3 года назад
Great 👍
@sher.5027
@sher.5027 2 года назад
Thankyou for your explanation, It is going to be helpful for my exam tomorrow.
@CarolineCA23
@CarolineCA23 2 года назад
Thank you for your hard work! Do you have example where it asks for calculations finding the type of bolt (known weight, and external force)?
@huuhungtran12
@huuhungtran12 2 года назад
thanks you so much for this useful lecture. i just have a question about the way to define Pb load based on External load ( 03:44 ) My understanding, for the pre-load condition, Bolt is under tensile load and members are under compression load. Then if we apply external load in tensile direction ( tensile load ), then members will be released the force. Mean that : force in bolt = Fi + Pexternal and Clamping force in plates = Fi - Pexternal Then it should not has C factor - Stiffness constant of the joint. please correct me if i was wrong. thank you so much !
@rishabhjain1696
@rishabhjain1696 Год назад
What software are you using to present all these items?
@kittitattungsakul2672
@kittitattungsakul2672 3 года назад
Thank you so much
@kristopherlowry1602
@kristopherlowry1602 2 года назад
Great job explaining! Is there a reference book to this information?
@tomclwd4756
@tomclwd4756 2 года назад
I personally have Shigley's Mechanical Engineering Design 11th edition (Chapter 8) and the video supports everyhting in the book. His videos are more clear and straight to the point.
@hazn136
@hazn136 3 года назад
Hi, thanks for the great video. which drawing pad are you using sir ?
@LessBoringLectures
@LessBoringLectures 3 года назад
Thanks! I was using a Surface Pro and the Whiteboard app. I've transitioned to an iPad Air 2020 since because of the constant stutter and slowdowns in Whiteboard
@axeld9108
@axeld9108 3 года назад
Greetings! Another amazing lecture, thank you. Just one question related to the final example, about the value of the fc friction coefficient. Are both (fc and f) 0.15? Shigley do not show the value for the fc coefficient in a steel-steel combination.
@LessBoringLectures
@LessBoringLectures 3 года назад
Yeah, the 0.15 values are just an assumption. Shigley's in fact doesn't show that steel to steel coefficient of friction. And thank you for the compliments!
@marwanabdelhamid7147
@marwanabdelhamid7147 3 года назад
would you give us the slides or pdf to just keep up, and thank you for the videos.
@joshpineda308
@joshpineda308 3 года назад
The equation shown at 5:42 (Fm = Pm - Fi), Fm is different from what you are stating and what is seen on the graph (Fm = Fi - Pm).
@joshpineda308
@joshpineda308 3 года назад
Actually you are correct and my comment is mistaken. The graph shows the y-axis as absolute value |F|. So your equation for Fm is correctly depicted.
@jimf671
@jimf671 11 месяцев назад
Do not let this person or anyone who believes this near any substantial engineering project. This is the same mistake made in Eurocode 2 some years ago and has probably resulted in thousands of building and bridges across Europe being improperly designed.
@kelumo7981
@kelumo7981 3 месяца назад
who gives a shyt what you think or believe?😏its obvious you have never been in a classroom where such simplifications are common..we all know what is required,we are not dumb brainiac🤬
@Dwindledoodoo
@Dwindledoodoo 2 дня назад
what do you mean? what happened?
@jimf671
@jimf671 День назад
@@Dwindledoodoo Hilti book showed the torque for the selected studs on a power station project as 270Nm. this was about 2007. Then the new codes were published and the new Hilti book said 150Nm. The workings that were published with the new code showed fasteners subject to factors of safety as though they were a concrete slab or a structural beam which is ridiculous. I put this to Hilti and it was referred back to their top people in Lichtenstein. The answer came back that yes, they knew it was wrong but it was the law now so they had to do it that way. So every building and piece of machinery in Europe is going to be improperly fixed to the ground? Yes. It's the law now. Not impressed. I haven't been doing that kind of work so I have no idea if any of that has been fixed in the intervening years.
Далее
The Incredible Strength of Bolted Joints
17:58
Просмотров 3,1 млн
Fatigue FAILURE CRITERIA in Just Over 10 Minutes!
11:35
Applied Bolting - Torque isn't Tension
5:04
Просмотров 166 тыс.
What is Torque? - Fastening Theory Part 1
5:41
Просмотров 235 тыс.