In this video I will do a test to find out if a 600va computer UPS inverter can handle 14.8 v 150Ah truck battery because it is designed to operate with a 12 volts 7ah battery.
My Dremel here : www.banggood.in/custlink/33Dy...
My Adjustable Power Supply : bit.ly/2IAhX6b
My Cordless Hammer drill:bit.ly/2qzpk7e
20%OFF Coupon Code for Hammer drill::BG7322
My MUSTOOL X1 Clamp Meter:bit.ly/32n1U3s
My Stainless steel digital Vernier caliper:bit.ly/2PlJElW
My Bench Drill Press:bit.ly/38rMc9V
Heat Shrink Tube : bit.ly/2whf9Dy
Follow Me At
INSTAGRAM : mrelectron_youtube
INSTRUCTABLES : www.instructables.com/member/...
===================================================
---- Thanks A Lot For Your Love & Support Guys ---
#mrelectron #12v #220v #ups #inverter #battery

Наука

Опубликовано:

 

2 июн 2020

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 566   
@MrElectron
@MrElectron 5 месяцев назад
*Join this channel to get access to perks:* ru-vid.com/show-UCWFbPzBb7dCyCWuBA-DBrMAjoin *Mr.Electron Patreon's Page* - www.patreon.com/mrelectron *Hindi Channel* - www.youtube.com/@Mr.ElectronHindi *Alternator Channel* - www.youtube.com/@mrelectron_alternator *Watsapp Channel* - whatsapp.com/channel/0029VaQmmRaFCCoWOf7huh3G
@Subgunman
@Subgunman 4 года назад
Good video! 1. You need to clean the battery. Any humidity in the air will cause the dirt on top of the battery to conduct and discharge the battery. 2. Batteries with plastic cases do not need to be placed on any type of insulator when on the ground or concrete. This was only a problem with the early batteries that used a porous rubber case around the cells. 3. Take some time and clean out the inside of the inverter. Dirt in there plus humidity will cause shorts and problems with the inverter. 4. Add a fan to the driver transistors heatsink inside the inverter and make sure to add additional cooling holes. It will prolong the life of the inverter. Heat inside the box will kill the electrolytic capacitors and the mosfets used to create the higher output voltage. Remember that manufactures use cheap Chinese caps that fail with heat. I sometimes replace all of the electrolytics with temperature rating greater than those originally supplied with the inverter. Keep up the good work, now on to solar charging of the battery!
@Voltechs-Tv
@Voltechs-Tv Год назад
Good bro
@skopyhoTechChannel
@skopyhoTechChannel 2 года назад
UPS might overheat when large capacity battery is used. heatsink inside UPS is usually small and not designed to long continuous operation because manufacture expect that battery will get discharged before internal components overheats. you should add fan to cool internals of ups.
@everythingandroidpro1850
@everythingandroidpro1850 2 года назад
I have a question my ups is 600VA and if i need to run my ps4 slim for 13 hours then how many amphours battery i need my ps4 takes 370ma and the internal battery is 7ah and at that battery my ps4 can run only 4 mins
@valuemastery
@valuemastery 2 года назад
@@everythingandroidpro1850 According to spec, the PS4 Slim uses between 55 and 110 watts. That's in line with your measurement of 370mA, which at 220V (I assume, you did not mention the voltage) equals to about 80W. So, for running it for 13 hours, you will need 13hx80W=1040Wh of stored energy. When the battery has 12V, it will need to have a capacity of 1040Wh/12V=87Ah. However, this does not include storage and conversion energy loss, plus you will need a reserve in the battery to not fully discharge it - Lead Acid batteries don't like full discharges, they will be dead in a short time. So your battery should be at least 120Ah. And of course, there's no point in running only the PS4. Maybe you would need a TV also, which uses power, so the battery would need to be even bigger. What's the point of running the PS4 from battery for 13 hours while the TV is connected to the mains? Then you could simply connect your PS4 to the mains too.
@louf7178
@louf7178 2 года назад
I know the concern about putting car batteries on PSUs is the desire to run high loads and at longer times than design parameters. I want to run the same load (router, modem and sleeping computer) for longer than my typical 30 minutes. Is this still a hazard?
@NeverEvil1
@NeverEvil1 2 года назад
@@everythingandroidpro1850 It would be cheaper to run an extension cord to your neighbors place.
@Yeklifestyle
@Yeklifestyle Год назад
@@valuemastery can two 12v40ah battery be connected together for this
@uwefrotscher9039
@uwefrotscher9039 2 года назад
My hero! whenever I see his experiments and his ideas he makes me laugh. They are pure abilities, without any special effects - just great.
@TheLastSock
@TheLastSock 2 года назад
the size of the battery is irelevent, you can stick a 12v 100000000000A battery and it will still run, the UPS only draws the current it needs, so for the original 7Ah that might have lasted say 10mins on ups, the larger 150A will last maybe 10-15 times longer, the 1000000000A longer still. Some off grid houses use submarine batteries with their ups, ive been using an old 270Ah marine battery on my old 500w inverter without any issues, standard lead acid batterys will eventually fail as they are not designed for deep cycling.
@piotrekj8447
@piotrekj8447 2 года назад
Podał pan 100000000000A to jest mocy 1000000000000W czyli 1000MW A to jest 1GW... takiej mocy w takiej formie w pudle malutkim nie jest możliwe nawet... nawet akumulatory od tira nie pomogą tutaj na 2sekundy. Ok? Teraz real. 600VA... 0,7cos... 420W max... czyli bierze 42A max? No 50A ... z akumulatora tira ok wytrzymać może 2h... I ładowanie dwa dni słabym prostownikiem...
@rileykirk11
@rileykirk11 2 года назад
its about the heat generated from the circuitry of running more than half its rated capacity for longer than what is possible with the stock battery these things get really hot its dangerous
@nevilleparis3932
@nevilleparis3932 2 года назад
As long as the voltage is withon range you should be fine. More ampere hour just means for runtime when the power fails and the ups inverter switches on battery
@JakubZahorik
@JakubZahorik Год назад
The internal charging circuit can be damaged due to the high charging load of the large battery. APC manufacturers works fine, many others will die.
@ostry875
@ostry875 Год назад
​@@piotrekj8447 a jak ups ma 400w i aku 2 ah to mocniejszy można dodać mu
@chandruasp
@chandruasp 3 года назад
I used the same with 60Ah car battery and sepperate smps tuned to 14.2v for Battlery charging. Still working nice.
@Voltechs-Tv
@Voltechs-Tv Год назад
Good bro
@deanbevier3389
@deanbevier3389 4 года назад
I have a standard UPS/Very large telecommunications backup battery type system. I put it together years ago. It charges passively and does not do anything until the power goes. It can keep all my devices and network up for a day. (I generally use it for my full size fride/freezer though) Nice to see somebody else "sort of" use a similar system.
@dineshjaryal1224
@dineshjaryal1224 3 года назад
i also have 600VA UPS can I connect 6*12V 7aH batteries with it? if yes, will it heat up the UPS circuit or damage it or I have to use any mini USB fan to coll down it? and with same UPS circuit can I Charge these batteries, if yes how much time it takes to charge, or I have to use any other ckt or charger to change it, if yes how to connect that chager with UPS ckt. Reply
@deanbevier3389
@deanbevier3389 3 года назад
@@dineshjaryal1224 Short answer, yes. If you have a 12V UPS only use12V batteries in parallel. I have never had a problem with overheating, etc. Just keep in mind the UPS can only charge at the rate it charged the original battery. If you need to charge your bank quicker, disconnect UPS (may not be necessary) and put a 12 charger on batteries at a rate acceptable for your bank size. I hope this helps.
@dineshjaryal1224
@dineshjaryal1224 3 года назад
@@deanbevier3389 thanks. But if I want to charge all batteries fast, will you please, help me how, if with extra external charger then how to connect.
@DL-kc8fc
@DL-kc8fc 3 года назад
@@dineshjaryal1224 As mentioned by the discussants above, it does not matter how high the battery capacity you have, as long as it is still a 12V battery. If you want more 12V batteries, you must connect them in parallel. Never in series !!! The UPS takes as much "A" as it needs ("A" behaves differently than "V"). Just look out for immediate withdrawal from the UPS. In your case, it's 600VA. You have to subtract 1/3 from this, so in reality it will offer you a maximum rated power of 400W (you can power a device that has a power input of up to 400W for a while). For longer power supply, make sure that it is up to 350W consumption (practically 600VA = 350W). It's good to stick to half, ie 600AV = 300W - your UPS will last you a very long time. That's enough for a TV, all the lighting in the house (if you have an LED), a computer, a 3D printer, ... Fast charging of the battery UPS does not provide, because it charges and maintains the battery with a value of several mA. Any car charger allows you to charge quickly. Charge each battery separately. If your charger can handle high outputs (depending on the manufacturer), it is possible to charge 12V batteries in parallel. Never in series connection !!!
@DL-kc8fc
@DL-kc8fc 3 года назад
@@deanbevier3389 Yes, the battery capacity does not affect any overheating, but only a higher output at the output than the nominal one. If the UPS is built to draw 350W (600VA), it is good not to exceed this value and the UPS will operate reliably for any length of time (my UPS 650AV IN LINE works like this for about 20 years in conjunction with one solar panel in a holiday cottage that has no power supply). energy). I chose the IN-LINE UPS because it does not require 220-240V to start from the mains. Just connect a 12V battery and the UPS will start working on its own. OFF-LINE UPSs require a connection to 220-240V to start and are therefore suitable for computers, etc. No UPS overheats, because the consumption is strictly monitored, for example, I turn on only the TV and lighting. If I want to turn on the computer, turn off the TV, etc., etc, etc. All this only from the old UPS. :)
@mikeshashu
@mikeshashu 2 года назад
Kind of genuine channels I love... No weird free energy junk👊😄
@jeffcameron7853
@jeffcameron7853 3 года назад
Love your videos dude. Making cool stuff with junk. Lots of videos show expensive equipment that I just can't afford.
@binilraag
@binilraag 2 года назад
Since Mr Electron is using an old battery, he can experiment with it. But for people who are going to try this with a new battery, please note that for tubular battery, you need atleast 6 to 8 ampere of charging current. The built in charger of the ups only produces around 1 amps of charging current. As Mr Electron is showing in the video, he is using a separate charger for charging the battery. Now if you guys want to use a new battery with a computer ups, add a charger with atleast 8 amps for 100ah batteries, 10 amps for 150ah batteries with a cutoff of 14.4v.
@augustusmshila9719
@augustusmshila9719 2 года назад
i have a 2kva battery with a n N40 battery.what should i do?
@suguganesan6982
@suguganesan6982 Год назад
For 32 ah battery, extra charger was needed?
@tomokmotorpart7599
@tomokmotorpart7599 Год назад
@@suguganesan6982 32ah/5=6.4amp max charger can use... 32ah with 1amp charger take around 1.5day/32hour to full charge
@Voltechs-Tv
@Voltechs-Tv Год назад
Good bro
@elrofernandez3576
@elrofernandez3576 10 месяцев назад
Can i connect battery charger and the ups at the same time? Is it okay?
@JeanDidier
@JeanDidier 2 года назад
Ah so this is actually possible!!! Thought about it but was too scared to try. Thank you!
@danieladonis1948
@danieladonis1948 Год назад
Corrosion around the positive terminal is generally believed to be the result of overcharging from the alternator
@karthikmani4144
@karthikmani4144 4 года назад
How can I use this pump for washing machine were no water pressure
@skaterawalsien6246
@skaterawalsien6246 3 года назад
Good day!, my analysis w/ ur vlog is ok provided that u step up d amps of ur UPS w/ d intent of longer time capacity,,, well i sugest if orig 12v7ah backup batt to beefup to higher 100ah u will provide a doublethrowswitch to jump the existing orig backup power w/ a required higher 12vamp
@user-lv3ge3je6s
@user-lv3ge3je6s Год назад
I run a 1000w UPS that was designed for 4 x 7.2AH in series (48V) with 4 x 190AH batteries. Now my battery bank is 200 kilos but it lasts for around 8 hours at half load giving me time to plug in my generator. Thanks for this great work and to answer your question, overcharging. Cover your terminal with grease, it will last for ages giving you much needed peace.
@Voltechs-Tv
@Voltechs-Tv Год назад
Good bro
@kotojeff7699
@kotojeff7699 7 месяцев назад
Hi, can the UPS charge the 4 x 190AH batteries without any modification ?
@Tokentools-weldersAu
@Tokentools-weldersAu 7 месяцев назад
Yes, charge takes longer, the load does not change, just the amount of energy required to replenish the cells changes
@shubhamchandra5417
@shubhamchandra5417 3 года назад
From personal experience; 33Ah car battery with a frontech electra, Do not plug in anything more than 150W. I thought aside from the routers and CCTV, a TV would be fine, but NO. Used with a TV for 2 weeks, and the last time when the TV was on, for 20 minutes, the battery input wires caught fire on the PCB. The traces are not large enough to carry enough current. Plug in light appliances.
@MrBinduajay
@MrBinduajay 4 года назад
Good presentation dude
@paramdyutidasprodip2342
@paramdyutidasprodip2342 3 года назад
Thanks for your excellent presentations.
@sankalpfauzdar1535
@sankalpfauzdar1535 3 года назад
My query different regarding this clamp meter is it's accuracy is good ? Are you satisfied mater's performance ?
@m.s.m3464
@m.s.m3464 4 года назад
Can you make a "workshop tour" to show us from where comes these fabulous inventions... great video BTW
@vaseemmehrancp9372
@vaseemmehrancp9372 3 года назад
Most of the Computer UPSs were designed to work under 30 minutes to save the making cost battery size. Connecting bigger batteries like 150Ah, there are some problems ahead, Transformer material are chosen cheaper rather than heat factors. Power switching devices like MOSFETs are also cheaper. Charging current for 150Ah battery is not sufficient from such UPSs .. they Might take larger time to get full charged. But I appreciate the way of your language and demonstration .. nice
@vaseemmehrancp9372
@vaseemmehrancp9372 3 года назад
But your source of charging is outstanding
@techgaming2024
@techgaming2024 2 года назад
you can add a fan to the ups
@rafiulla3436
@rafiulla3436 Год назад
But if I add cooling fan, will that help to run for longer time without any problem to ups board? Please answer.
@luckydubeinrc5165
@luckydubeinrc5165 Год назад
mine working for 5 years no problem 600 watt version Victron x 2 220 a batteries, charging by 470 w solar to controller, then controller to battery,
@Voltechs-Tv
@Voltechs-Tv Год назад
Good bro
@somaraju8631
@somaraju8631 2 года назад
This is an awesome video boss. How long we can draw the current from this battery, assuming the battery is fully charged and connected to the same UPS you have shown. I want to connect it to my gaming desktop.
@ranbirsingh6641
@ranbirsingh6641 3 года назад
Will the charing circuit of ups not work? You are using a seperate chaging unit.
@mohanakrishnanp6934
@mohanakrishnanp6934 4 года назад
It's because why charging and discharging positive terminal get even more oxidation compare the negative terminal.
@callmart-6347
@callmart-6347 3 года назад
Its an awesome experiment and small trick with the 15v 3amps laptop charger instead of diot u can add pwm 10 amp solar charge controller u can put the charger as solar input for more protection and much safer 😉
@luckydubeinrc5165
@luckydubeinrc5165 Год назад
solar charger needs pure dc not rippled dc! controller will be damaged or not work!
@Voltechs-Tv
@Voltechs-Tv Год назад
Good bro
@skaterawalsien6246
@skaterawalsien6246 3 года назад
Cont... in that way u can extend the service power time of ur UPS. & if outside pwer resume click d switch back 2 orig backup batt coz d UPS is rated only to recharge d juice of d 12v7ah....
@tushar673353
@tushar673353 4 года назад
put a 40mm or 80mm if possible cooling fan in ups to prevent from heating the Tx...
@InzemamZahidi911
@InzemamZahidi911 4 года назад
yes rit , because it now has increased work load, I was thinking the same.
@MrTHORN888
@MrTHORN888 4 года назад
hello brother , i have one UPS but it not working , how to fix it ? please help me !
@jec_ecart
@jec_ecart 4 года назад
Why do you need 3 cable joints ? Just have one good set of wires from inside to clamps.
@ramborums
@ramborums Год назад
Does the charging have to be monitored if using a laptop charger? Do they have a charging control circuit? Even if they do, they must be designed for lithium ion batteries right?
@Deep_Thoughts99
@Deep_Thoughts99 3 года назад
Wow my wished video, I have the same inverter and wanted to use bigger battery, and you have solved my problem. Thanks dear
@ZeeDeeLicious
@ZeeDeeLicious 3 года назад
Really useful Video. Few Questions: does the UPS not charge the battery as well and keep it at a floating charge? if so why use a separate charger? Does the UPS not overheat or get to a temperature which could damage it over a long period of use? im asking this as i have heard a PC UPS is not designed for long periods of use that's why i watched your Video but does not mention anything about it as i want to do the same thing to my ups. please let me know Thanks
@luckydubeinrc5165
@luckydubeinrc5165 Год назад
ups only charge 1 amp... so add a 6 amp or 12 amp charger depending on battery ah..his one needs 20 amp charger.
@legominimovieproductions
@legominimovieproductions 3 года назад
If you charge the battery through the ups, one, the ups chargwr circuit will blow up and two, if it does not blow up, the wrong charging/standby voltage of the ups charging circuit will kill your battery in a couple cycles
@Save_Andhra
@Save_Andhra 3 года назад
I want to buy The best clamp multi meter, can you suggest the best? and also the one you are using in the video what is the brand and specs?
@mhexbalmora7799
@mhexbalmora7799 2 года назад
Some of UPS it will run only for a certain time or just a 5 minutes only the beep warning for cutt off then it will stop. How to reset the UPS timer for continues operation as an off grid inveter? Thanks Sir..
@nnejiamaechi9385
@nnejiamaechi9385 Год назад
Great effort. Pls can one charge the battery also with the ups charger by attaching solar charger controller.? If yes does therefore mean it can dischsrge and charge at the Sam time? I mean conneting to electricity
@explorer4850
@explorer4850 3 года назад
Multimeter details please Your multimeter clamp also Measure the DC amps??
@reubenodhiambo8200
@reubenodhiambo8200 2 года назад
Hi, I got ups connected to a 12v100ah (free maintenance battery) swapped this with the small battery inside. I don’t have the measurements tools right now, but is the battery getting charged? Is it an upgrade for the smaller 12v7ah that was inside the ups?
@veekul26july1984
@veekul26july1984 2 года назад
Is it safe to use 20ah battery with this ups inverter for longer periods
@bjoernandersen8287
@bjoernandersen8287 4 года назад
What a mess in that workshop, how about cleaning up dust, rust and get some red and black cables to the 12 volt circuits? Surprised that it all worked well.
@rafiulla3436
@rafiulla3436 Год назад
Since this ups components are made to run for less time, But if I add cooling fan, will that help to run for longer time without any problem to ups board? Please answer. I'm planning to make one for home like this, if any additional things are required please advise.
@debasisdas1362
@debasisdas1362 4 года назад
bhai app ka mustool clamp meter kesa chal raha he & it is best or not ?
@trekzindia7141
@trekzindia7141 4 года назад
Can we change ups battery with a lead acid battery of 75ah?
@basharmmd
@basharmmd 3 года назад
Why did you not charge the battery by connecting UPS to electricity as designed in the UPS device of the company?
@haxboi5492
@haxboi5492 Год назад
I would add a fan or two since it will run longer than designed so it will heat up more
@brijeshjaiswalgoa
@brijeshjaiswalgoa 2 года назад
Keep your place neat and clean. It's so untidy.... How do you work...?
@thetribal697
@thetribal697 Год назад
Nice work but charging current is very low from the UPS, you have to use a separate charger.
@ianvisser7899
@ianvisser7899 Год назад
How'd you manage to bypass the 5 min auto-shutoff? Most UPS's dont run till they are drained, they run for 5 min max, then cutoff, due to internal timer.
@syamtechindia9951
@syamtechindia9951 3 года назад
Is that mosfet is capable of taking 35 amps instead of 7 amps. In long time working?..
@sunilgeorgethomas9071
@sunilgeorgethomas9071 4 года назад
which is the clamp meter used in this video.. if possible give a link to buy.
@debasisdas1362
@debasisdas1362 4 года назад
can i measure dc&ac mAMP current... on mustool x1 clamp meter ....?
@anishpatel5715
@anishpatel5715 4 года назад
I like to throw out, the way you charge that is max of 4A from the psu, but after long draw it can catch fire. To charge you need a regulated psu
@anantagarwal3859
@anantagarwal3859 3 года назад
How much backup can a 650watt ups gives in 150ah inverter battery
@sankeths3036
@sankeths3036 3 года назад
Bro it produce square wave. But we need pure sine wave as output.
@skaterawalsien6246
@skaterawalsien6246 3 года назад
CONT... ive watch another vlog beef uf his UPS like my suggstion it went alright extending th service time of his UPS...SIR UR A GENUISE!!!! TY
@uchendulucky913
@uchendulucky913 Год назад
How do you charge the battery? Can the light coming from ups be use to charge the battery please I need answers
@jitpaliwal
@jitpaliwal 2 года назад
Bro good video ....Keep it up I have a online ups 600 w and dc 36v . Now my all three battery not giving backup if I purchase new battery then almost 30v three battery cost around 10000 . Spend 10000 on Old ups this good or not ?? Or available any other cheap way to use my online 600 w (36v)ups ???? Please guide me.
@ultralinks8726
@ultralinks8726 3 года назад
Giving 300 watts load by Using a 65Ah battery with my 650 VA intex ups, will it be safe?
@johnwang9914
@johnwang9914 2 года назад
The UPS itself can charge the battery and likely supports at least stage 2 bulk charging and stage 3 float charging and maybe a maintenance trickle charger voltage. Using the laptop power supply only provides a crude stage 2 bulk charge which will produce a lot of hydrogen gas. The real question is if the UPS charging circuit could withstand the much longer duration stage 2 bulk charge of the higher capacity battery and would it cutoff, current cycle or current limit if the battery was depleted enough to require stage 1 charging, even car chargers often have a manual switch for stage 1 charging and recommend that the charging should not be unattended (the current cycling is very noisy that I often can't stand being in the garage when stage 1 charging, fortunately you don't need a lot of stage 1 before stage 2 is possible).
@clownbooface2624
@clownbooface2624 Год назад
Yes but its not designed to charge such a large battery and will die in short order
@johnwang9914
@johnwang9914 Год назад
@@clownbooface2624 True, a UPS is not intended to be used continuously in such a fashion, but it would work till it fails and indeed has worked in the field for most of a year in Trinidad and indeed had not failed on the project to the point where a manager against my advice, ordered the UPS to be reconditioned for use in the Houston office after the Trinidad project completed, my advice was to junk the UPS after the project. Our competitors had shorted out the fuse box at the Trinmar office and smoked their computers so our line manager had asked me for how the power differences between that of the Trinmar office and our computers could be temporarily accounted for, hence we simply used the inverters in a UPS continuously by cutting a few wires. Seems like what was required in this video was for an even shorter duration than what we had done with a UPS at the Trinmar office. UPS's are fundamentally simple and robust.
@kriangdeach
@kriangdeach Год назад
@@johnwang9914 ข
@Voltechs-Tv
@Voltechs-Tv Год назад
Good bro
@aloga7136
@aloga7136 2 года назад
que es eso que lleva en los tapones 4:49 ? que se ve algo así como el nivel del agua de las baterías o presión de la batería. Dónde se compra, porque es interesante saber el estado de la batería. what is it that is in the plugs 4:49? It looks something like the water level of the batteries or battery pressure. Where to buy, because it is interesting to know the state of the battery.
@vanitagoel9
@vanitagoel9 10 месяцев назад
Can we connect a 2kva ups to power home lights fan etc and then connect it further with 2kva normal inverter which has bigger batteries so that power failures is low. My point of connecting online ups is so that all electronic items connected to my 5a sockets are safe as ups gives online power , we extend the power to ups by normal inverter which has cheaper batteries and in case of power failures we get no fluctation and delay in power and saves electronic equipment.
@RDCST
@RDCST 2 года назад
Put 3 4mm wires of same length in parallel to connect the battery to the UPS and as short as possible. Also the UPS usually turn of if the voltage drops to 10.8V and is measured at PCB level, so if you have 11.5V at battery and 10.8V at PCB it will turn of anyway. Every mV counts on low voltage with that amount of current.
@PHM_Tech
@PHM_Tech 2 года назад
I agree
@luckydubeinrc5165
@luckydubeinrc5165 Год назад
funny mine turns of at 12,4v 600 watt version
@RDCST
@RDCST Год назад
@@luckydubeinrc5165 You must measure the voltaje at PCB board level not at battery posts.
@ricoigor
@ricoigor 2 года назад
If you connect the ups to an outlet, wouldnt it charge the battery?
@elmermercadal8546
@elmermercadal8546 2 года назад
Hi Sir, just one question. Can i use my UPS 12v positive and negative terminal connected to a 12V 7A battery as a power supply for my 12v cctv unit? I will just remove the battery and use the + & - wires and connect it to the cctv power supply, Is it possible sir.
@naturefarm3422
@naturefarm3422 3 года назад
Hello Sir, how to enough 1.2 AMS in 150 Ah battery
@skidkev6421
@skidkev6421 10 месяцев назад
What do you mean by battery self discharging on wooden or plastic floors? Please explain it so we don't make that mistake. Thanks.
@AlexandreYordanov
@AlexandreYordanov 2 года назад
Hello Mr. Electron I tried to connect my 12V 7Ah UPS Inverter ( 220v ) o my tubular 150 Amp 12 volts battery and it did not work .Can the 14.4 volts of the battery ruin my ups inverter ?
@politicsfromabasicguy1498
@politicsfromabasicguy1498 2 года назад
so I have some questions to ask Do I have to consider the ups amps n car battery amps when doing this What if the UPS failed will it affect my laptop
@paulomock3741
@paulomock3741 3 года назад
Why did you have to charge the battery separetly? Isnt that the UPS charge the battery by itself??
@electrotesla3545
@electrotesla3545 2 года назад
If a DC motor is connected to another DC motor to rotate it will provide uninterrupted power ?
@chefrancis
@chefrancis 3 года назад
Can a 600va ups be upgraded with 180amp car/truck battery
@karthikmani4144
@karthikmani4144 4 года назад
Hi Pls help how to make solar operating induction stove so I can avoid gas bill
@DL-kc8fc
@DL-kc8fc 3 года назад
Experts do it best, but expect a large investment and a long return. As an amateur, it can be done for half price, but it will not meet all the parameters.
@dineshjaryal1224
@dineshjaryal1224 3 года назад
i also have 600VA UPS can I connect 6*12V 7aH batteries with it? if yes, will it heat up the UPS circuit or damage it or I have to use any mini USB fan to coll down it? and with same UPS circuit can I Charge these batteries, if yes how much time it takes to charge, or I have to use any other ckt or charger to change it, if yes how to connect that chager with UPS ckt. Reply
@douglundy5755
@douglundy5755 Год назад
Excellent work and thanks so much!
@tech_ji_solar_electronics
@tech_ji_solar_electronics 3 года назад
Brother lcd TV will work in ups in 7ah battery how much hours it will work
@jednorrislopez2792
@jednorrislopez2792 3 года назад
respect, sir! can I use this method to a normal theatre subwoofer? thanks
@tushar673353
@tushar673353 3 года назад
does your ups shuts down after 5min after the transformer gets hot? mine is work only for 5 min and then shuts down... its powersafe ups
@OctavMandru
@OctavMandru 2 года назад
You can run multiple 4mm wires in paralel to make up for the smaller section. Don't run 31A through a 4 mm^2 wire, it will overheat
@profast786
@profast786 2 года назад
Yes you can use multiple wire . My system has 2 wire . Of same length.
@tomokmotorpart7599
@tomokmotorpart7599 Год назад
yes... 4mm cable x 2 = 10mm cable single
@basilkasimi2646
@basilkasimi2646 Год назад
Can it power a small size fridge if connected with a big battery?
@sureshshah2685
@sureshshah2685 4 года назад
Positive terminal of battery get corroded because of the presence of positive charge of H+ ion as battery has h2so4 acid inside it. (Answer to the hidden question)
@Ragavenutb
@Ragavenutb 2 года назад
The shown method doesn't work with Apc rs 600 ups, as soon as the batteries are connected it senses higher capacity connected and shut downs the ups within seconds but with intex ups it works but also separate charging device is needed the power mosfet on ups heats too much and gets shuts down so the charging relay on the ups has to be disabled and only load switching relay has to be enabled always & a 80mm fan may help cool other passive components but not charging circuit.
@stefanmansukhani8797
@stefanmansukhani8797 2 года назад
How do you disable the UPS charging circuit?
@ZaidSirrou
@ZaidSirrou 2 месяца назад
Since nr electron I wanna just ask you please about the time it takes the battery after decharge to get charge Thank you for replying ❤
@melkiorwiseman5234
@melkiorwiseman5234 Год назад
Without even watching the video I already know the answer is yes, it will work on that battery. There is a fairly wide battery voltage tolerance in those UPSs (I'd guess it would be around plus or minus four volts) and the only effect on a larger battery is that it charges very, very slowly since that UPS is designed to charge a much smaller capacity battery. This could cause sulphation in a lead-acid battery which would reduce its life. A LiFePo4 (Lithium Iron-Phosphate) technology battery would probably be a better choice in this application.
@Voltechs-Tv
@Voltechs-Tv Год назад
Good bro
@mandirdarshanarti
@mandirdarshanarti 3 года назад
How come 600w ups output to 50w 4 nos lamp 20w tube light 4 nos 50 w another light
@maramahauhnar5939
@maramahauhnar5939 2 года назад
Does that means that, we can use UPS as an inverter?
@eunice962
@eunice962 4 года назад
my UPS keep on beeping while being connected to the car battery is it ok?
@TheAryabhatta
@TheAryabhatta 11 месяцев назад
Hi, I want to replace the battery of the Computer UPS battery with Solar panel. Hence guide me to tweak the UPS.
@Ricinberg
@Ricinberg 7 месяцев назад
I love your workshop setup 😊
@MrElectron
@MrElectron 5 месяцев назад
Thank you! 😊
@kaviyarasudurai7704
@kaviyarasudurai7704 2 года назад
Bro can you say me the resister which responsible for auto cut off below 100watt use
@AdrianVay-kp6te
@AdrianVay-kp6te 5 месяцев назад
Did you check the working up of the invertor transistors? They probably need more cooling, to be shure of long functioning. A small ventilator perhaps.
@MrElectron
@MrElectron 5 месяцев назад
👍correct
@mohit4you
@mohit4you 3 года назад
Hi ! I connected luminus 600 va to 150 ah battery. It gives output but within a minute current disconnect and it off like battery is drain while battery is full . Any suggestions!
@thokozanigwathi4249
@thokozanigwathi4249 Год назад
This works I am using it as we speak but. The problems is always the charging capacity. It's not designed change huge 150 ah batteries. So it takes more time to charge the batteries
@hectalex-ox9vm
@hectalex-ox9vm Год назад
porque el diodo va en el negativo,,he visto muchos videos y dice que es en el positivo
@tyronbamping6104
@tyronbamping6104 2 года назад
Good work my man!
@naseemiqbalghumman3254
@naseemiqbalghumman3254 3 месяца назад
Exellent Video. I was looking for..that how to connect heavy Battery with Apc Es 700
@kjuirteerdserty9618
@kjuirteerdserty9618 3 года назад
why was the diode put at the negative terminal?
@nagsupratim
@nagsupratim 4 года назад
Bhai why SMF vrla battery is not recommended for inverter use.
@julianslab1511
@julianslab1511 4 года назад
Due to the chemistry of the battery, when current is drawn from the battery, the chemical reactions of lead and acid in the battery cause the positive terminal to rust. (Answer to hidden question )
@_gfxg
@_gfxg 2 года назад
ive got a ups with a capacity of 700Ah/360w can i put a 100A battery on it and it will be fine?
@zebonolibez1140
@zebonolibez1140 2 года назад
Cant you charge the inverter battery using the UPS?
Далее
Convert old UPS into SOLAR Generator
11:51
Просмотров 176 тыс.
Ultimate Battery Backup Hack/Mod.
10:12
Просмотров 5 млн
Best exercises to lose weight ! 😱
00:19
Просмотров 7 млн
Difference Between UPS & Inverter - Dr AMP Ep 3
5:13
How to Repair 12 volt Battery || 12v battery repair
9:56
2200VA UPS APC to Solar Inverter
19:32
Просмотров 145 тыс.
SUPER UPS Battery Hack- Mikes Inventions
8:45
Просмотров 261 тыс.
how to make 12 volt to 220 volt ips?
10:17
Просмотров 503 тыс.
How does an Uninterruptible Power Supply (UPS) work?
16:00
DIY Solar Generator
9:30
Просмотров 1,6 млн
#engineering #diy #amazing #electronic #fyp
0:59
Просмотров 2,4 млн