Carrier Infinity Furnace Code #42 ??? 

Michigan Heating Guy
Подписаться 20 тыс.
Просмотров 9 тыс.
50% 1

Опубликовано:

 

25 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 57   
@hughholt121
@hughholt121 Год назад
One nice thing Joe the customer can tune to your channel and see what you found and the corrections you made all the way in Florida. That is certainly a nice wi-fi set up you sold him. Glad you are feeling better. Stay warm.
@stephenbullock1443
@stephenbullock1443 Год назад
Excellent diagnostic on the furnace.
@maddrive7355
@maddrive7355 Год назад
I also have this type of furnace 58MVB. My error code is 42, INDUCER MOTOR FAULT. To fix the problem I remove and empty the trap, then roll the paper towel into small q-tips and stick the end into the 3/8 hole of the black plastic chamber to remove condensate water. The paper towel wicks the water out which I repeat about 10 times. Now I put everything back to gether and it starts up every time.
@bobgallo3775
@bobgallo3775 Год назад
I have found over the years, that if the pressure switch gets wet, replace it. Just like the gas valve, these components are not made to get wet.
@jasonreist2528
@jasonreist2528 Год назад
I agree on the changing of the pressure switches and the annual maintenance.
@acrservicesmathewr7565
@acrservicesmathewr7565 Год назад
I was working on a modulating Bryant gas furnace recently. Inducer was seized. Replaced it and now a bad gas valve not modulating with inducer. Replaced that. Found psi incoming to low causing problems with carbonizing burner tubes. What a money hog these things are. Not an easy part to change either. Very touchy and specific when it comes to pressures. Lp by the way. If 13.5 isn’t being supplied. It will never work. High fire 11 and low at 2. What a difference it made. Regulator and ambient dropped the psi to low. So take in acct on LP the colder it gets the lower ur pressure will be
@Jason-wc3fh
@Jason-wc3fh Год назад
lp at 11? overfired much? 10 is typically the maximum. Sounds like there should have been a LPCO installed ahead of the valve when it was converted to propane.
@acrservicesmathewr7565
@acrservicesmathewr7565 Год назад
@@Jason-wc3fh specs on unit say no lower then 11 on high fire and 13.5 incoming
@stephenjanssen7173
@stephenjanssen7173 10 месяцев назад
Thanks for the great video. I have the same furnace. On a longer heat call, it seems like when it does need the high speed (after trying to achieve temp on low, then med) it kicks out after only about 1 minute on the high. Wondering if that pressure switch for the highest speed has gone bad and the others work as low/medium seems to be working fine. Also, had no idea that you could blow through pressure switches with your mouth like that. I thought they were too sensitive for that.
@JCT442
@JCT442 Год назад
Two years without cleaning the trap is just asking for it... pay a little in pm now or lots in repairs later. An old story quickly forgotten by most.
@JCT442
@JCT442 Год назад
One thing I've noticed about your jobs on Carrier furnaces is most, if not all of them are stained/rusted under the inducer. I've gone thru 3 inducers on my '08 Infinity furnace and all three inducers leaked out the bottom where the two casing sides are clipped together. I wonder if this is a widespread quality issue with Carrier inducers.
@tphvac87
@tphvac87 Год назад
ECM inducer was a terrible idea on carrier’s part, one question “Why?” Normal ones pull like .15 amps are you really saving that much $$$$? Why reinvent the wheel 🤷‍♂️ just my thoughts
@djijspeakerguy4628
@djijspeakerguy4628 Год назад
10:26 I had to live with this sound waking me up every morning for the last decade, except ours was twice as loud! Also had a super loud grinding/scraping noise during startup for a while, but got that fixed last year some time. Our furnace (Bryant Plus 90i) finally completely failed a month or so ago, in a super concerning series of events. It smelled really badly like burning plastic in the house, so we called the fire dept. No fire, but the furnace was unusually hot. Apparently, it was on, but no air came through the vents, so the thermostat upstairs kept calling for heat! The furnace was overheating as a result. All of this was caused by a burned out blower motor, hence the smell. Our walls were super hot around it. Fire dept. said there would have been a fire if we weren’t home! Got it replaced with Trane S9x2 and it’s so quiet we can barely hear it.
@Gabe-kv2zs
@Gabe-kv2zs Год назад
My 1997 Plus 90i has been grinding/chirping for a few years now. It's finally throwing the code 42 and probably is about to do something similar. Thankfully winter is almost over and I have furnace estimates taking place now. Good furnace...bad design on the inducer being connected to the control board (making it nearly impossible to replace the bearings). 😌
@nolanharris640
@nolanharris640 Год назад
42 inducer fault and I believe I had to change the gas valve with it, I absolutely hate the infinity and I installed carrier for a decade. The propane burns too dirty on the lower stages.
@danobrien3109
@danobrien3109 Год назад
Nice work Joe, go home have a good weekend. The old HVAC guy in Toronto.👍👍🇨🇦
@machone1757
@machone1757 Год назад
Not Liking the Smoke Detectors Chripping Great Video
@williamserver4332
@williamserver4332 Год назад
Crazy how many cycles that thing has ran. Great video.
@JasonTurner
@JasonTurner Год назад
I put one of these in my last house in 2004 and it was running at 96+% efficient when we sold the house in 2021. It was a beast for sure!
@RoyEdwards-fe9ez
@RoyEdwards-fe9ez 10 месяцев назад
Code 42 means some type of communication error. Dont understand why water in the condensate trap will stop furnace from coming on
@chadschafer1723
@chadschafer1723 Год назад
A plus install on that thermostat lol
@biker55555
@biker55555 Год назад
With that many cycles in 2 heating seasons, the furnace is more than likely oversized. I did some math using 6 months of daily heating, it's turning on at least every 8-10 minutes.
@MiHeatingGuy
@MiHeatingGuy Год назад
And what should it be ???. Do you know how much your furnace runs.
@biker55555
@biker55555 Год назад
Not sure if you are seriously asking me... was a manual J performed "properly" to size this furnace?
@MiHeatingGuy
@MiHeatingGuy Год назад
Yes
@tedsmith5058
@tedsmith5058 Год назад
Hello from the great state of Michigan
@bill944
@bill944 Год назад
The company I work for deals in Lennox. I'm not thrilled with the usual 45 minute wait that I get when I call tech support the few times I call. On the other hand, I've had two different customers that have Carrier equipment where I've called tech support three times for communication problems with Infinity systems. I get an answering machine with Carrier and I've left the model numbers, serial numbers and all of the info they ask for. The first message I left was five months ago. Still waiting for a return call. Good thing it was an intermittent problem that would clear itself.
@Thatplumberguy1995
@Thatplumberguy1995 Год назад
Carrier doesn’t have a tech support anymore you are supposed to call the local carrier dealer and they are supposed to have “service technicians” that take the place of tech support
@bill944
@bill944 Год назад
@@Thatplumberguy1995 Supposed to is correct. Apparently they just push you off and forget about you.
@Jason-wc3fh
@Jason-wc3fh Год назад
@@Thatplumberguy1995 Well people should stop buying their products then. A real tech support is what is needed and nobody knows the system more than the ones who make them. Tech support can save a lot of time when you're someone who deals with dozens of different products and hundreds of different equipment and can't be a master of all.
@stevencossaboon3237
@stevencossaboon3237 Год назад
Good job Joe.
@danbell1733
@danbell1733 Год назад
Needs a heat exchanger probably, they all need them eventually.
@bobbywanger8123
@bobbywanger8123 Год назад
You have done a good job 👍👍👍👍👍👍👍👍🔥🔥🔥🔥🔥🔥🔥🔥
@JamesBrown-db9pk
@JamesBrown-db9pk Год назад
i woundt own that craopo
@Hvac-dude
@Hvac-dude Год назад
Where did u get that specific carrier infinty control they are nice thermostat when I start getting out in the field I wanted to put a couple on my truck
@MiHeatingGuy
@MiHeatingGuy Год назад
Cost too much to just carry on the truck
@5822huron
@5822huron Год назад
You must be knew! Those cost almost $1000
@Hvac-dude
@Hvac-dude Год назад
@@5822huron I'm still learning things I had no clue they were that much money
@croyal4240
@croyal4240 Год назад
Have a customer with an Infinity thermostat that says malfuction .What could that mean ?
@jameslang9170
@jameslang9170 Год назад
It means call a professional
@raymondgillott587
@raymondgillott587 Год назад
nice job
@MiHeatingGuy
@MiHeatingGuy Год назад
Thanks!
@justsayen2024
@justsayen2024 Год назад
80%ers only 95s aren't worth the money,too much to go wrong.
@shanew7361
@shanew7361 Год назад
As a homeowner how does one maintain this?
@Jon-hx7pe
@Jon-hx7pe Год назад
unless you know what you're doing and understand the theory behind how the equipment operates, get maintenance done professionally
@5822huron
@5822huron Год назад
You can't man! We go to school for this! Everything is not DIY...
@shanew7361
@shanew7361 Год назад
@@5822huron That sucks!
@uxwbill
@uxwbill Год назад
There are some things you can do, like changing or cleaning the air filter or making sure your thermostat has good batteries in it. If you can get there safely, check to make sure the combustion ventilation pipes are kept free of ice and snow. Should you have the manual for your furnace, check it for any additional maintenance steps you can take. Test your furnace or air conditioner before the heating or cooling season begins. Don't shut too many registers, even if you have rooms you aren't using. And when either system is operating, pay attention to how they sound. A change in the sounds these systems make could indicate a need for service. Definitely do know your limits -- and when that time comes, call a trustworthy technician.
@dand3975
@dand3975 Год назад
Shane, the main maintenance you can do is change the air filter, check the flame rod & clean, clean condensation trap in side furnace, and clean screen on air intake pipe at inlet to furnace.
@stevenb9913
@stevenb9913 Год назад
3 psi switches? I installed my infinity in 04 and it has two psi switches. What is the third for?
@MiHeatingGuy
@MiHeatingGuy Год назад
04 Infinity was only a 2 stage furnace. I think carrier changed to 3 stage in 07 or 08
@stevenb9913
@stevenb9913 Год назад
@@MiHeatingGuy i have been out of the residential for a while. Been working a industrial gig for a ling time. Thank you for the responce
@daddygc5814
@daddygc5814 Год назад
Too much over the top technology and not really needed
@croyal4240
@croyal4240 Год назад
As Steve Lav would say "got a chirpa" !
@zack9912000
@zack9912000 Год назад
Ecobess builds better thermostat, he better pray that ECM ventor motor never fails. Thise are stupid expensive
@MiHeatingGuy
@MiHeatingGuy Год назад
Do you know how makes this thermostat ???
@fordman1776
@fordman1776 Год назад
Where can I get that ecm inducer tester?
Далее
Check This Before Doing Any Furnace Repair
13:25
Просмотров 6 тыс.
My DIY Geothermal System Was So CHEAP!!!
19:35
Просмотров 2,9 млн
He went ALL in 😭
00:12
Просмотров 1,9 млн
Three NEW MAPS in Update 0.31.0 Nightmare | Standoff 2
01:48
Furnace Gas Valve Not Opening - How to Fix It
8:16
Просмотров 20 тыс.
Common Carrier Furnace Repair
27:09
Просмотров 7 тыс.
Carrier Infinity inducer motor replacement
8:44
Carrier 58 Series ECM Blower Motor Replacement
37:00
Carrier/Bryant inducer motor change out #340793-762
20:44
Carrier Furnace another clogged heat exchange fail
13:07
2008 Carrier Infinity and An Upset Customer!
12:57
Просмотров 32 тыс.