Caterpillar Model : C-15 / 625KVA / 500KW Generator, Error Reset And Test Run. 

GE tec
Подписаться 519
Просмотров 3,6 тыс.
50% 1

The C15 diesel generator sets have been developed for mission critical, standby and prime applications. Producing reliable power from 320 to 500kw at 60 Hz, meeting ISO 8528-5 transient response requirements and built to accept 100 percent rated load in one step.
Maximum Rating: 500kW
Frequency: 60 Hz

Опубликовано:

 

4 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 7   
@ryianf.almelor6645
@ryianf.almelor6645 2 года назад
This is really awesome and very educational. Thanks for sharing your knowledge & tips, Gyan.
@aktarulsekh2992
@aktarulsekh2992 2 года назад
very good making your video
@getec_GETEC
@getec_GETEC 2 года назад
Thank you brother 💙💙
@davidbediakohammond8734
@davidbediakohammond8734 2 года назад
What is the maximum temperature of the generator
@getec_GETEC
@getec_GETEC 2 года назад
temperature 105 'C 189 'F
@testpreparation7916
@testpreparation7916 5 месяцев назад
sp2 fault how set any idea
@getec_GETEC
@getec_GETEC 5 месяцев назад
TROUBLESHOOTING USING SP FAULT CODES SP (Spare Input) Fault Codes are associated with four inputs that are considered spare inputs. Spare fault code programming is contained in OP6-0, Protective Relay Programming (see WP 0085, Table 7 for details). These codes are not stored in the GSC fault log. When a spare input fault is detected, the FAULT SHUTDOWN lamp flashes and the corresponding code (SP1, SP2, etc.) is displayed on the upper GSC display. Fault condition on SP 1 and 4 is programmed to shut down the engine immediately. WARNING Fuels used in the generator set are flammable. When filling the fuel tank, maintain metal-to-metal contact between filler nozzle and fuel tank opening to eliminate static electrical discharge. Failure to comply can result in flames and possible explosion and cause injury or death to personnel and damage to the generator set. Fuels used with the generator set are flammable. Do not smoke or use open flames when performing maintenance. Failure to comply can result in flames and possible explosion and can cause injury or death to personnel and damage to the generator set. NOTE SP1 thru SP4 must be evaluated using dedicated shutdown lights, alarm conditions, and available fault codes.
Далее
CATERPILLAR GENERATOR LOAD TEST
14:02
Просмотров 27 тыс.
Troubleshooting a no start on CAT C15
10:08
Просмотров 14 тыс.
How To Use Cat ET. Cat Electronic Technician.
12:55
Просмотров 117 тыс.
Understanding Porsche's New Six Stroke Engine Patent
21:57
How 3 Phase Power works: why 3 phases?
14:41
Просмотров 1,2 млн
The REAL Problem with Smart Meters
20:05
Просмотров 552 тыс.