Тёмный

Cleaning of fcu strainer and flushing of coil system (🙏please subscribe) 

henyong mangyan tv
Подписаться 3,1 тыс.
Просмотров 33 тыс.
50% 1

-- Cleaning and flushing of chilled water piping system is very important.
-- To removed all debris, dust and even metallic parts enter the system.
-- To ensure system flow continuity.

Опубликовано:

 

16 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 102   
@aldemofficial
@aldemofficial 3 года назад
Lupit m tlaga kumalikot lodi maski saang bagay. Keep safe always gdbless
@maelenali
@maelenali 3 года назад
Guys pls keep on watching po. I support bro by not skipping any Ads..👌👌👌👍👍👍
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 3 года назад
Salamat best kapatid sa support..
@henrylloydsolano2842
@henrylloydsolano2842 2 года назад
Goog joob master napaka laking tulong tlga itong mga video mu ngaun ku lang n kita sna dti ku p hinanap pero salamat n din at s pag titingin ku s utube e labas ung video mu n ito kya dali dali kung pina nood kakapasok ku lang po kc s maintenance dto s dubai all around kme dto s mga plat company nmen kya malaking tulong skin itong video mu master. hindi ku alam etung lahat ng ito kc Refrigeration aku ngaun lang aku nk hawak s Chilled water isa n ngaun aku s susubaybay s mga ilalabas mung video.. Good job master tuloy mu lang marami kang matuturuaan s pamamagitan ng share ng mga video mu n to..
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 2 года назад
Maraming salamat po at akoy nagagalak at kahit papaano naishare ko sa inyo yung mga natutunan. Cg lang po wag kang mananawang panoorin ang mga videos ko. Kung may katanungan ka message kalang at matutulungan kita dyan.
@sandeepsingh-jg8rg
@sandeepsingh-jg8rg 2 года назад
Very good vedio please DVR value about information give
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 4 года назад
Maraming salamat po sa mga nanood at manonood pa. Sana po wag nyong kakalimutan na mag subscribe at i like. Please pa support naman po ng channel ko. Salamat
@pinoymaster1067
@pinoymaster1067 Год назад
Yan Ang Pinoy mahusay
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog Год назад
Syempre basta pinoy maabilidad salamat po
@ROYALHVAC
@ROYALHVAC 2 года назад
Nice ❤️❤️
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 2 года назад
Pls subscribe me also. Thanks
@nadeem3298
@nadeem3298 Год назад
Good job sir 💯
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog Год назад
Thanks
@mohamedjameen6039
@mohamedjameen6039 3 года назад
Why Blower unit body outside and Main duct out side is coming more dryness of water?
@maelenali
@maelenali 4 года назад
👍👍👍
@leomhelabuda4521
@leomhelabuda4521 Год назад
Sama na po ba paglinis ng strainer sa paglinis ng aircon unit chilled water sir?
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog Год назад
Opo sir pag na pm ng fcu dapat kasama ang strainer
@actechnician4281
@actechnician4281 3 года назад
Congrats po mone kana.
@jollyscaria1922
@jollyscaria1922 2 года назад
Vrey good shering thsnkyou my brethers welcome all time welcome best all gues
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 2 года назад
You're welcome brother pls subscribe my channel ok. Thank you
@allancaiden
@allancaiden Год назад
How much labor Ng ganyan services sa chilled water master?
@hvactech6312
@hvactech6312 3 года назад
Salamat sa pagbahagi Master... God bless.. Tapus na ako Master. Sana puntahan mo run ako. BISAKOL17 ang channel ko salamat
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 3 года назад
Salamat..cg po. Dalawin ko bahay mo
@rycajayon6534
@rycajayon6534 Год назад
Master pwede po ba mag back wash kahit umaandar yung cooling tower and circulating pump? Basta i off lang po yung supply valve and return valve?
@vincentabellaginez1838
@vincentabellaginez1838 2 года назад
san ba nakalagay ang aqtuator motorized valve
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 2 года назад
Ang motorized valve ay nasa return pipe ng fcu.yung pinakakabitan ng actuator motor
@jhonpaulibanez6267
@jhonpaulibanez6267 5 месяцев назад
saan kaya pwedeng bumili ng wye strainer mga boss nabutas na kasi yung treed ng endcap ng wye strainer eh
@erwinmendoza7658
@erwinmendoza7658 3 месяца назад
Sir no need naba Isarado ang supply ng mall Diba mababawasan ang tubing nila sa chiller
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 3 месяца назад
Hnd naman na kaylangan saraduhan sa main kc meron naman yan valve sa may unit mismo dun mo lang isasarado.
@elmerromero7556
@elmerromero7556 4 месяца назад
Bakit po kaya sa katagalan sir nagkakaroon ng cracked yung strainer po ?
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 3 месяца назад
Sa paghigpit po yun ng cap. Dapat alalay lang sa paghigpit.
@rajeshji6071
@rajeshji6071 3 года назад
Tq
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 3 года назад
Pls subscribe. Thanks
@kristinevillapando7211
@kristinevillapando7211 3 года назад
boss sa mga split type unit san banda makikita yan new subscriber mo boss more vid sir
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 3 года назад
Itong unit na eh chiiled water and nagpapalamig. Fcu lang ito. Kung sa split ac unit. Freon gas sya. Yung filter or strainer drier nasa outdoor unit. After ng condenser coil. Bago pumasok sa expansion valve or capillary tube.
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 3 года назад
Salamat sa pagsuporta po. God bless u.
@kristinevillapando7211
@kristinevillapando7211 3 года назад
@@Henyongmangyanmotovlog maraming salamat sir last question sir okay naman yung lamig sir pero nagyeyelo yung indoor unit nya ano ba pwde ma suggest mo sakin sir para masolusyunan ko yung ganun problema. salamat ulit
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 3 года назад
Depende kc yan. Marami ka dapat titingnan pagganun ang problema. * Check mo yung gas pressure kung tama ang charge. * Check mo yung control baka hnd sya nag automatic. Baka Continuous ang operation ng unit. * Check mo yung evaporator coil kung malinis. Kc baka hnd nya na aabsorb yung lamig. * Check mo yung anti- ice sensor. .* Check mo yung operation ng blower. * Check mo yung capillary tube baka barado na. Remedy: reproccess mo. Vaccumin mo ng maayos, i flushing mo yung indoor at outdoor unit. Tingnan mo yung termostat kung ok pa. Ok salamat sa suporta. God bless
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 2 года назад
Thank you so much for watching this video even short video only. Please don't forget to support my channel just click SUBSCRIBE and bell. Thank you so much. God bless you all
@goniosman7173
@goniosman7173 Год назад
I want to know something
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog Год назад
Yes? Question?
@goniosman7173
@goniosman7173 Год назад
I chiller 7 lavel. My question is 6 lavel cooling only 1 lavel no cooling. I washing steiner relise water but no colling. Whate is the Problem
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog Год назад
The problem is. There's air inside the pipe. You should install automatic relief valve to the unit which not cooling. Check here i have one video. Where you install the relief valve. Thank you
@mohammadshahzad779
@mohammadshahzad779 3 месяца назад
Bro my fcu return line not cooling supply line child and stainer also cleaned and water also clean I removed 3 bucket water clean water
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 3 месяца назад
@mohammadshahzad779 check the opening of actuator valve. Maybe the actuator motor doesn't work .
@sfchannel764
@sfchannel764 2 года назад
To do flushing, bypass valve need to open or close?
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 2 года назад
No. Do not open. Just return valve only.
@sfchannel764
@sfchannel764 2 года назад
@@Henyongmangyanmotovlog actuator valve also need to open or close?
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 2 года назад
It should be. Just turn on the unit and set to lower temp setting like 16°
@hasstoua7276
@hasstoua7276 2 года назад
@@Henyongmangyanmotovlog bypass valve should always be open , when u flush u close it and when u finish u open it again
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 2 года назад
Bypass valve is always closed. Don't open when you are doing flushing. Even the unit is working.
@ashikas1090
@ashikas1090 2 года назад
Bro how to adjust picv valve
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 2 года назад
What do you adjust? The opening? Just remove the motor and you will see there's a number 1to5 then you can adjust the opening. In the valve.
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 2 года назад
Pls don't forget to subscribe.thank you. If you have any questions just leave your message here and i will answer all your questions. Thank you
@ashikas1090
@ashikas1090 2 года назад
Another question FCU getting off after I ON It's getting off in 5 or 10 minutes again I need to on it wats the issue
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 2 года назад
@@ashikas1090 pls check the thermostat control. Maybe the control is defective.
@deocarloadao6350
@deocarloadao6350 2 года назад
Nice vedio sir,new subscriber here!.
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 2 года назад
Thank you 💕💕
@deocarloadao6350
@deocarloadao6350 2 года назад
Sa return ba nakalagay ang strainer sir?..salamat sa vedio malaki natutunan...
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 2 года назад
@@deocarloadao6350 yes lods nasa return pipe ang strainer
@deocarloadao6350
@deocarloadao6350 2 года назад
@@Henyongmangyanmotovlog salamat lods San ka pala boss?
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 2 года назад
@@deocarloadao6350 mindoro lods. Qatar ako nag work nag for good .ako. umuwi na
@CABIX_81
@CABIX_81 3 года назад
Sorry if u mind me asking,, are u certified hvac? How much u make an hour, are u working in a hotel?
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 3 года назад
i have been in the hvac field for 15 years. so that i have incountered all the troubles of hvac
@CABIX_81
@CABIX_81 3 года назад
@@Henyongmangyanmotovlog ive just started doing hvac same as u in a hotel,, exactly what u do is what i do,, any tips and tricks. Salamat po
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 3 года назад
@@CABIX_81 if you have any questions dont hesitate to ask me. Thanks for your support.
@johnrexgaduyon3020
@johnrexgaduyon3020 3 года назад
Sir. Ano po mauuna. Motorized valve or ung strainer?
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 3 года назад
ang nauuna po dyan ay ang strainer. nakakabit yan sa suppy pipe ng chilled water. bago pumasok ang chilled water sa unit dadaan muna sa strainer para yung mga dumi sa tubig ay hind pumasok sa coil ng unit, para hindi sya magbara. then, yung motorized valve naman, ay after ng coil. sa return pipe ng unit. sa labas na ng return pipe. yan yung nagkocontrol ng flow ng tubig. at ang nagkocontrol sa motorized motor ay ang thermostat. at ang nagcocontrol sa thermostat ay ang room temperature.. ok po. salamat po sa mga katanungan.. tanong lang po kayo at aking sasagutin sa ngalan ng aking konteng nalalaman.
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 3 года назад
Lods saan ba Banda yung tumutulo? Sa ilalim ba ng drain pan? O sa chilled water pipe?
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 3 года назад
Itong pong paglinis ng strainer ay para lumamig yung coil. Kc pag madumi yan hnd 💯 na pqpasok yung tubig sa loob ng coil. Hnd sya mqg ccerculate ang tubig
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 3 года назад
Moisture yan ng tubig ng drain pan. Ibig sabihin may tubig sa drain pan hnd sya na uubos. Kaylangan i adjust mo ang level nga unit. Itaas mo sa kabilang side para yung lahat ng condensation ng coil deretso sa drain pipe. Tapos lagyan mo narin ng drain pan insulation.
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 3 года назад
Split unit po yan. Duct type. Adjust mo lang yung level ng unit taas mo yung isang side papunta yung tubig sa drain pipe.
@elmerromero7556
@elmerromero7556 2 года назад
Saan po ba nanggagaling yung chilled water supply po ng FCU ? Sa chiller po ba,Sir ?
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 2 года назад
Opo tama ka sa chiller unit galing yun.
@elmerromero7556
@elmerromero7556 2 года назад
@@Henyongmangyanmotovlog ask ko lang po Sir. Di po ba marumi ang chilled water return from fcu it means umiikot lang po ba ang tubig papuntang chiller hanggang cooling tower po ? Naguguluhan po kc ako sa cycle ng chilled water,Sir ee .,
@elmerromero7556
@elmerromero7556 2 года назад
@@Henyongmangyanmotovlog Sir,ask ko lang po kung saan galing ang tubig na sinusupply ng chilled water papuntang mga FCU ? yung tubig din po ba yun na nanggaling sa Cooling Tower ?
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 2 года назад
@@elmerromero7556 hindi po yung tubig sa cooling tower ay nagpapalamig lang sa condeser coil. May ibang tubig ang umiikot sa chiller. Umiikot yung sa evaporator sheel and tube na sinicerculate naman ng cerculating pump pappunta sa bawal unit
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 2 года назад
May mga strainers po yang mga chillers. Malalaking strainers kaya bago nya isupply yung tubig malinis na.
@balongride3169
@balongride3169 3 года назад
Sir hindi na ba kailangan iopen yong gate valve nya sa bypass? Return lang kasi inopen nyo sir na nakita ko... Salamat sir sa video mo. Matagal na ako naghahanap ng ganitong vlog kasi nasa maintenance din ako. More video please sir Keep safe and God bless 🙏👍👍💕
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 3 года назад
Salamat po sa support
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 3 года назад
Hnd na kaylangan iopen para maflushing yung coil nya. Kc pag inopen mo ang bypass hnd mag secerculate yung tubig sa coil
@balongride3169
@balongride3169 3 года назад
@@Henyongmangyanmotovlog Salamat din po sir sa pagsagot sa tanong ko. Patuloy ko po kayong susuportahan kasi malaking tulong itong channel nyo sa mga kababayan natin na may mga katanungan patungkol sa maintenance. Sana po hindi kayo magsasawang sumagot palagi o kaya tumulong sa mga nangangailangan.
@ritchesumayang4253
@ritchesumayang4253 3 года назад
boss return bah standard naka lagay ang striner nya
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 3 года назад
Hnd po dapat nasa supply nakalagay ang strainer bago pumasok sa coil
@balongride2368
@balongride2368 3 года назад
Sir tanong ko lang po. Meron pong magkakaiba ang pwesto ng mga gate valve at strainer diba? Paano po yong mga ganong sitwasyon sir? Itong nasa video nyo po ata ngayon yong strainer nya nakakabit before gate valve papuntang coil? Salamat sir
@Henyongmangyanmotovlog
@Henyongmangyanmotovlog 3 года назад
Hnd yun nagkkaiba ganun talaga ang pwesto nya. Gate valve muna bago strainer kc hnd mo mabbuksan ang strainer kung ito ang mauuna sa gate valve. Yung gate valve pang patay ng supply ng chilled water.
Далее
Cleaning Y-Strainer of Chiller Condenser Pipe System
5:33
ceiling cassette chiller water installation
9:21
Просмотров 18 тыс.
Electromagnetic Aircraft Launcher
15:09
Просмотров 1,4 млн
Cleaning a NASTY Evaporator Coil!! HVAC Service Call
11:00
Chiled water piping connect to FCU
26:09
Просмотров 26 тыс.