Common boiler feed system mistakes 

Boiler Room Detective
Подписаться 1,3 тыс.
Просмотров 272
50% 1

In this video, I describe some of the common issues I see when looking at the boiler feed unit. I discuss the need for a strainer, the importance of the tank vent and the overflow, what master traps are a bad idea, and the proper discharge piping components.

Наука

Опубликовано:

 

23 май 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 14   
@nethoncho
@nethoncho 2 месяца назад
So many years of experience offered in this video. Thanks for sharing
@boilerroomdetective
@boilerroomdetective 2 месяца назад
Thank you for your comment and support
@smalljobrob6432
@smalljobrob6432 2 месяца назад
Very good review.
@boilerroomdetective
@boilerroomdetective 2 месяца назад
Thanks I appreciate it
@Mike-rm7vf
@Mike-rm7vf 2 месяца назад
Good video again Ray. I think contractors should also know to use sch. 80 piping as well as the better fittings also. 👍
@boilerroomdetective
@boilerroomdetective 2 месяца назад
Yes sir I was thinking of adding it but didn’t want the video to be too long Thanks
@gerard-nagle
@gerard-nagle 2 месяца назад
Excellent video, hugely informative. Two questions, why the use of two check valves, in case one fails I would think? Also, if the boilers goes into vacuum, there isn't really anything to be done, as it will flood, or can a vacuum breaker be put on the boiler?
@boilerroomdetective
@boilerroomdetective 2 месяца назад
Thanks for the feedback Rite boiler recommends it I think a single check valve should work I do use vacuum breakers on steam boilers
@Mike-rm7vf
@Mike-rm7vf 2 месяца назад
On all our large boilers we use 3/4” brass traps with a swing check installed backwards above the water column assembly
@boilerroomdetective
@boilerroomdetective 2 месяца назад
@@Mike-rm7vf that's a good idea Does the check valve leak?
@Mike-rm7vf
@Mike-rm7vf 2 месяца назад
@@boilerroomdetective it does not. The little bit of condensate in the brass trap keeps the swing check pushed closed when under pressure. I’ve used Hoffman #26s in the past and they usually bite the dust after a few years especially in an application that has an automated steam valve on steam supply causing the boiler to go into vacuum frequently.
@boilerroomdetective
@boilerroomdetective 2 месяца назад
@@Mike-rm7vf Thanks
@marriagepartnersministry5942
@marriagepartnersministry5942 2 месяца назад
Is it accurate to say proper boiler chemicals will neutralize and eliminate carbonic acid and pitting?
@boilerroomdetective
@boilerroomdetective 2 месяца назад
You would have to ask a water treatment expert but if the boiler is running properly the chemicals don’t leave the boiler
Далее
Case of inadvertent law suit
4:28
Просмотров 144
Wirtz pumps are really clever
12:05
Просмотров 13 млн
Я тоже так могу
00:12
Просмотров 897 тыс.
СМОТРИМ YOUTUBE В МАЙНКРАФТЕ
00:34
Просмотров 1,1 млн
The Problem with Wind Energy
16:47
Просмотров 2,1 млн
The Most Underrated Ancient Projectile
14:49
Просмотров 523 тыс.
USS Ernest G. Small - “Who Needs a Bow Anyway?"
13:40
Case of why are the pipes banging
3:51
Просмотров 371