Configuring an S7-1200/S7-1500 to communicate with Microsoft SQL Database using Tabular Data Stream 

AutomationStation
Подписаться 4,4 тыс.
Просмотров 16 тыс.
50% 1

Would you like to be able to read and write data directly to and from an SQL server using your S7-1200 or S7-1500 PLC? Press play!
Check our other video to learn how to set Microsoft SQL Express from scratch:
• Setting up Microsoft S...
You can find the LSql_Microsoft library here:
support.industry.siemens.com/...

Наука

Опубликовано:

 

5 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 90   
@piterNovy
@piterNovy 3 года назад
Great video!! A few weeks ago I set up a 1500 PLC as a FTP client sending about 1500 real values every 5 minutes to a .csv log file located in a simatic ipc!
@AutomationStation
@AutomationStation 3 года назад
Nice work!
@shanehodgson4290
@shanehodgson4290 2 года назад
HI, I'm trying to use V2.1 of this block in an S71200 and keep getting an area length error. This version doesn't require line 386 to be commented out as the manual states that the block will work with an S7-1200 from firmware V4.4 or higher (I am using V4.5) it does however state that the parameter "data" must be interconnected with an "Array of Byte" when using a S7-1200. A Structure is not permitted. Does it just mean i need to change the "data" datatype to be an array of bytes rather than the structure? Any help would be much appreciated.
@mafrafree
@mafrafree Год назад
Hello, in the Siemens link there is no longer the project for TIA V.16, Where i can find it ?
@LuisCardoso-uj5co
@LuisCardoso-uj5co 3 года назад
Hello, i'm having a problem on an S7-1200, I'm getting the Status 8605 and the SubfunctionStatus 8088. What am I missing here? Thanks in advance.
@lcart1064
@lcart1064 3 года назад
Thanks for the informative video! I'm getting error 8605 - "Error when calling TRCV". Haven't been able to find much online about how to fix this... any ideas would be appreciated.
@yaroslavlyulko2298
@yaroslavlyulko2298 2 года назад
Have you any idea how to check result of sql query? For example if i execute command with query 'bla-bla-bla' - I will not see that this query not executed on SQL Server side.
@user-mg8li2jv8z
@user-mg8li2jv8z 3 года назад
Guys, everyone who has error 8602 - see the connection settings (SqlConfig DB). Recheck IP settings, InterfaceID, port number carefully . Also check the settings on the SQL side I had this same error. The problem turned out to be in the InterfaceID number. I put up the number 64, although I did not have it in the system constants (there were only 65 and 66 for each port) and it all worked Everything worked fine with the PLCSIM Advanced v3 upd1 (through PLCSIM Virtual Eth. Adapter) and latest for this moment MS SQL Now I am suffering with receiving a large amount of data from the database. Until I won (
@sagamoreful
@sagamoreful 3 месяца назад
I completely stuck there I don't know what else I can do
@chrissibrandner
@chrissibrandner 4 года назад
Thank you for the interesting video. Is it also possible to send sensor values instead of those predefined values?
@AutomationStation
@AutomationStation 4 года назад
Yes, absolutely. This was just a mere example to prove that it works, what you send is up to you and you can even read data back!
@cptchaos8
@cptchaos8 3 года назад
Hi. What do I need that I can setup a permanent communication for data exchange between s7-300 plc and SQL Server? Is there a service necessary or do I have to stay online in Tia portal all the time?? I just wanna write data from plc every 10-20 seconds into sql server database. Else I have to use OPC UA and there you use a service that runs...
@AutomationStation
@AutomationStation 3 года назад
I don't think there's any library available for S7-300 so you might be best off having an intermediate IPC that will talk to your S7-300 and then access the SQL server. Or move to a S7-1500 ;)
@richardstatie5392
@richardstatie5392 3 года назад
Thank you for sharing this. Great tutorial. I did follow all the steps, but I'm at the end when I'm trying to start the communication from the S7-1200 with my PC, I'm getting the fault message: 8602. In the subfunctionstatus: 80C6. I don't know what I'm missing here. The fault message comes up even before I try to send a message. It looks like the communication is not working between the PLC and the PC. Do you have any suggestions?
@AutomationStation
@AutomationStation 3 года назад
I'd suggest checking our other video that shows you how to set SQL Express from scratch: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-JuletfZOP-M.html Once you go through this I'd confirm that you can access your database using Server Management Studio. If this doesn't work, you won't be able to connect from your PLC either and it means that you have either not configured your Microsoft SQL database correctly or something like a firewall or your specific network topology is causing issues
@Plcwhiz
@Plcwhiz 2 года назад
Hi how do i send Timestamps from The S&-1200 to SQL. I have concatenated the time stamp data but it is not appearing in SQL
@davidgemelli
@davidgemelli 3 года назад
Hello, this work on tia portal V15?
@utkarshsingh175
@utkarshsingh175 4 года назад
Wow.. this is a very nice demo... Is this feature supported by PLC Sim Advance 3.0 ??
@AutomationStation
@AutomationStation 4 года назад
Even better - it works with PLCSim Advanced V2 as FW V2.6 is perfectly fine. Just tested it just to be on the safe side ;) Fun fact? It didn't work! Why? Because I turned off my SQL server ... With the server on it works perfectly fine! Thanks for watching
@bassistemre
@bassistemre 4 года назад
Good video, first of all thank you! But I have a question. How can I run this project with S7-1200? I tried to copy paste the material from existing project to blank S7-1200 project and an error occured which says: Drop/Insert(0026:000071) A test cannot be copied. Only one test instance of type version Lsql_Microsoft V0.0.8 is permitted. Only released type instances can be copied. Please! What should I do?
@AutomationStation
@AutomationStation 4 года назад
Check the types folder in you project library - this message is indicating you have put one of the types (Lsql_Microsoft) in edit mode. Right click it and select “discard changes” to restore back to a released version.
@leminhhieu0912
@leminhhieu0912 4 года назад
Thanks for your great video, and i have a question for you. Now, i dont have CPU S7-1500, maybe, can i use PLCSim to do it ? when i use PLC sim Advance to simulate S7-1511. Using example project of Siemens, when enableLsql =1 , Status = 16#8602, SubfunctionStatus = 80C5.
@AutomationStation
@AutomationStation 4 года назад
I tested it for another viewer and works perfectly fine with PLCSim Advanced. If you open the block itself you can check what these codes mean, hopefully they'll point you in the right direction. Also, did you check whether you can connect to the database using something like the Management Studio?
@leminhhieu0912
@leminhhieu0912 4 года назад
@@AutomationStation In my PC, i am using SQL server 2014. in this video, you use SQL server 2017, can SQL server 2014 connect ?
@utkarshsingh175
@utkarshsingh175 4 года назад
I am also getting the same Error, 16#8602 & 16#80C5 using PLCSImAdvance 3.0 & Example project of Siemens.
@AutomationStation
@AutomationStation 4 года назад
Well I haven't tested with V3 but works perfectly fine with V2
@hectorhirammirandaflores661
@hectorhirammirandaflores661 3 года назад
I have the same error and still can´t figure out what is the problem
@user-bh1on2xi3m
@user-bh1on2xi3m 4 года назад
If you need to read the SQL DATA , how to use it.
@muhammadzafariqbal9822
@muhammadzafariqbal9822 3 года назад
hi nice video but how to transfer character data from tia portal string to sql DB like (apple mango) 1234 easy transfer but character not going can you explain thanks
@manjunathnagaling4872
@manjunathnagaling4872 3 года назад
Hiiii....what are the preconditions to configure SQL data to siemens scada system.?
@AutomationStation
@AutomationStation 3 года назад
Not sure I get your question. If you talk about setting up SQL for WinCC I'd advise checking the WinCC manual, should have all the preconditions
@lamsonlemai6516
@lamsonlemai6516 3 года назад
Thanks for your video, but can I use this method for MySQL, ? I have seen a topic of MySQL of siemens forum but it’s so difficult to understand totally
@AutomationStation
@AutomationStation 3 года назад
I'm afraid this would only work with Microsoft SQL
@lamsonlemai6516
@lamsonlemai6516 3 года назад
When I use this example for S7-1200. An error occurs because FC Write to array is not supported. :(
@AutomationStation
@AutomationStation 3 года назад
@@lamsonlemai6516 ​ There are restriction on what S7-1200 can do which I mention in the video and are also listed in the documentation. For it to work with S7-1200 you need to comment few lines. Check 12:10
@lamsonlemai6516
@lamsonlemai6516 3 года назад
@@AutomationStation thank you very much.
@MrChantid
@MrChantid 5 месяцев назад
Able to write data in to MySQL or not?
@alexisneculpan3932
@alexisneculpan3932 2 года назад
hi .....how many values ​​can you send from a 1200 to a database??
@AutomationStation
@AutomationStation 2 года назад
Good question, I have not seen any performance values. I would suggest monitoring communication load of the PLC
@user-bh1on2xi3m
@user-bh1on2xi3m 3 года назад
I run a select query I don't know how to retrieve data and read the values.
@AutomationStation
@AutomationStation 3 года назад
There's a new version of the block available on the Siemens support site that supports SELECT, make sure to use this one and check the documentation for more info on how to do it
@user-bh1on2xi3m
@user-bh1on2xi3m 4 года назад
Archive len = 67174534 , Is it normal?
@ashiqmumtaz8726
@ashiqmumtaz8726 3 года назад
HI, Is it possible to connect S7-1200/1500 to Azure Database?
@AutomationStation
@AutomationStation 3 года назад
Not this way. For Azure check our MQTT video. Most cloud services like Azure or AWS use MQTT brokers so you need to have an MQTT client on your PLC to connect and send data to it. An alternative would be a hardware solution like the Cloudconnect 7 for example.
@williamvidorette3797
@williamvidorette3797 Год назад
Hi, do you have de example in TIA PORTAL V16 to share? On the siemens page is in TIA V17.
@AutomationStation
@AutomationStation Год назад
I dont think I do, sorry. You could try opening the v17 blocks in a trial version and copying them to v16 maybe
@williamvidorette3797
@williamvidorette3797 Год назад
@@AutomationStation Hello friend, thanks for the reply, I got the v16 version
@mafrafree
@mafrafree Год назад
@@williamvidorette3797 Where did you find ?
@williamvidorette3797
@williamvidorette3797 Год назад
@@mafrafree Hello friend, I got it from the person who posted another video, if you want, give me your email, I'll try to send it to you
@kaleshnarayan2010
@kaleshnarayan2010 3 года назад
Hi dear thank you for the video ,,please tell me how can i connect sql with plc sim advance , Is it possible? please let me know
@AutomationStation
@AutomationStation 3 года назад
Well I tested it with PLCSim Advanced V2 as FW V2.6 and it works perfectly fine so should also work with V3 FW V2.8
@tranngoctam8419
@tranngoctam8419 Год назад
Good video! I ask you to guide how to connect PLC S7-1200 with SQL server using domain name, Thanks
@user-bh1on2xi3m
@user-bh1on2xi3m 4 года назад
Archiving received data (enableArchive, db, dbmax)----------->How to use?
@user-bh1on2xi3m
@user-bh1on2xi3m 3 года назад
How to use the select command? to s7-1500
@AutomationStation
@AutomationStation 3 года назад
There's a new version of the block available on the Siemens support site that supports SELECT, make sure to use this one and check the documentation for more info on how to do it
@binor2286
@binor2286 Год назад
Guys I got an interesting error , so when I enable the SQL. The code turn to 7002 which is completely normal but after 17s (yes I'd count and each time it's 17sec) it turns to the error code 8602, sub function status 80C6 in state 3 . Does anyone had an idea on how to fix this problem ?
@sagamoreful
@sagamoreful 3 месяца назад
Did you solve it?
@binor2286
@binor2286 2 месяца назад
@@sagamoreful no I never found a solution even on Siemens forums
@YogeshPatil-wv8zj
@YogeshPatil-wv8zj 3 года назад
It is very good video. Can you provide same program in V15 version
@AutomationStation
@AutomationStation 3 года назад
Sorry I'm afraid I don't even have V15 installed and don't think the blocks support V15... You could get yourself a trial of V16 though and see if you can migrate the blocks to V15
@user-bh1on2xi3m
@user-bh1on2xi3m 4 года назад
S7-1500 Example 'insert into PLCDATA values (5,6,7)' If it's in the s7-1500 DB way, how to write
@AutomationStation
@AutomationStation 4 года назад
Hello again! If what you're after is writing some dynamic data rather than predefined values to your SQL Database, that's pretty easy. If you look at the command at 11:26 you just need to build the command yourself by concatenating some strings. I'd make another function which would take my values as the input, and the table name as another input, concatenate these into an SQL command and then spit out the command and then I'd use this command as the actual parameter for my sqlCommand input. I was actually going to do it but didn't want to add extra blocks and confuse people ;)
@user-bh1on2xi3m
@user-bh1on2xi3m 4 года назад
@@AutomationStation Wait for your example, thank you.
@user-bh1on2xi3m
@user-bh1on2xi3m 4 года назад
I can read and write To salsy Microsoft SQL Server?
@AutomationStation
@AutomationStation 4 года назад
@@user-bh1on2xi3m Not sure what you mean by salsy, but it's possible to both read and write data from and to the SQL Server
@user-bh1on2xi3m
@user-bh1on2xi3m 4 года назад
@@AutomationStation Archiving received data (enableArchive, db, dbmax)----------->How to use?
@ag7258
@ag7258 3 года назад
Sir how I get lsql microsoft function block
@AutomationStation
@AutomationStation 3 года назад
Check the video description
@ag7258
@ag7258 3 года назад
@@AutomationStation got link but how I download Plz help
@ag7258
@ag7258 3 года назад
Can it work for tia 15
@user-bh1on2xi3m
@user-bh1on2xi3m 3 года назад
If you need to read the SQL DATA , how to use it.
@egors9279
@egors9279 4 года назад
Thanks for the excellent demonstration of a really useful feature. Is it possible to read data back from the SQL database in the same way?
@AutomationStation
@AutomationStation 4 года назад
Sure! That's when you'd use the enableArchive, db and dbmax pins on the Lsql_Microsoft block.
@garyharrison9146
@garyharrison9146 4 года назад
@@AutomationStation but how do you read back in 1200 without the archive?
@AutomationStation
@AutomationStation 4 года назад
Hi Garry, yeah I'm afraid that's only possible with the S7-1500
@garyharrison9146
@garyharrison9146 4 года назад
@@AutomationStation you can actually do it. I managed to get it to read back in a 1200 . Also noticed the block isn't developed far enough for example it doesn't handle useful production db scenarios i.e. long insert or query commands. Had to modify that. Good concept but not good for memory space on plc or production ready for tracking parts etc.
@PelleTampio
@PelleTampio 4 года назад
@@garyharrison9146 Hi, we have a demo with the siemens "stock" example and we find the sqlcommand limited with string only. I can fit 6 analog measurements + column names with string [255]. Any tips how to change this before i hit siemens with support request? Requirement for us is max data length from plc - > sql to avoid manual splicing and time sync of the data to be send. Pdf Manual says 65kbyte send and receive limit so there should be a trick to use something else than string 255 for send. Also the datablocks have quite a lot of room for more than a string. Annoying siemens did not straight away give notes how to extend the example limits.
@user-bh1on2xi3m
@user-bh1on2xi3m 3 года назад
I run a select query I don't know how to retrieve data and read the values.
@AutomationStation
@AutomationStation 3 года назад
I'm afraid that SELECT might not be implemented in the block yet. Feel free to try to do it yourself though
@lehel121
@lehel121 3 года назад
did you implementet. or it was to hard?
Далее
ТЫ С ДРУГОМ В ДЕТСТВЕ😂#shorts
01:00
Советы на всё лето 4 @postworkllc
00:23
Why The Windows Phone Failed
24:08
Просмотров 227 тыс.
S7-1200 Data logging Siemens PLC
18:08
Просмотров 206 тыс.
iPhone socket cleaning #Fixit
0:30
Просмотров 18 млн
Мой новый мега монитор!🤯
1:00
Просмотров 600 тыс.
iPhone socket cleaning #Fixit
0:30
Просмотров 18 млн
Это iPhone 16
0:52
Просмотров 522 тыс.