@mkmotaleb
@mkmotaleb Год назад
Very good
@rachidtermoul4949
@rachidtermoul4949 7 лет назад
very good thank you.
@arpad-tamasszekely1853
@arpad-tamasszekely1853 5 лет назад
I would like to know the final solution for making work the whole system. How you make it the D0002 to read the status of the inverter, which indicates that the inverter receives the proper orders and executes it. It is not shown in your video, you stop it and come back when it is already working. Please help :)
@mmaad2165
@mmaad2165 5 лет назад
You have to put the address 4000D
@5106ush
@5106ush 6 лет назад
잘 봤습니다
@meladisak
@meladisak 5 лет назад
I WANT UNDERSTAND THE ADDRESSING SYSTEM FOR EXAMPLE WHY FOR IG5A ADDRESS 0X0006 WE WRITE IN P2P SETTING 0X3005. THANKS
@anvinh8372
@anvinh8372 5 лет назад
-1 ( with LS)
@dstankiewicz
@dstankiewicz 4 года назад
@@anvinh8372 Why it's -1, is there any documentation for this?
@AbdulHaseeb-pp2kb
@AbdulHaseeb-pp2kb Год назад
What is F00092 flag in p2p? where it is defined?
@sridharansri6964
@sridharansri6964 7 лет назад
sir i am sridharan i working auto machine program omron plc now i need learn ls plc your videos for me good use sir but sir i not understand your use move option you give 5060-5057 which adrass sir this for modbus
@wlgnsrnr
@wlgnsrnr 6 лет назад
I think that's mean bit control , For example , 1 word '0000000000000000' = 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 ->15B, 14B, 13B, 12B, 11B, 10B, 9B, 8B, 7B, 6B, 5B, 4B, 3B, 2B, 1B (B=BIT) , anyway.. in this video '8m57sec_ Table' , B2= Reverse run, B1= Forward run, B0-stop , each bit is on, that's means '1'... So, decimal 5060 change to bin 0001001111000100 = 000 10011 11 000 100 = 000, 10011, 11, 100 = 0, 19, 3, 0, 2 ->totally Reserved, Freq.command : Communication, Run command :Communication, 0, Reverse run
@wlgnsrnr
@wlgnsrnr 6 лет назад
and before the run inverter have to change drive mode:3 , drive frequency mode :7 , i60: select destination number, i61: choose communication speed (baudrate?) on the inverter, // and also on the this video , point 2min~4min have to select destination number (inverter's station number) each
@paulsiero9910
@paulsiero9910 4 года назад
@@wlgnsrnr trouble shooting
@wlgnsrnr
@wlgnsrnr 4 года назад
@@paulsiero9910 ?
@waseekhan8446
@waseekhan8446 5 лет назад
How to work your last read status bit D0002 You stop the video and set Kindly tell us
@arpad-tamasszekely1853
@arpad-tamasszekely1853 5 лет назад
Do you get any answer?
@mmaad2165
@mmaad2165 5 лет назад
Hi man. I've found the answer You have to put the address 4000D
@arpad-tamasszekely1853
@arpad-tamasszekely1853 5 лет назад
@@mmaad2165 Thank you man! It worked perfectly!!!
@mmaad2165
@mmaad2165 5 лет назад
@@arpad-tamasszekely1853 you're so welcome
@mohamedshark9169
@mohamedshark9169 4 года назад
Why u write B2 to 5060 ?!
@anhtuan4304
@anhtuan4304 4 года назад
Chạy được không ?
@HaiTran-gw1cx
@HaiTran-gw1cx 2 года назад
Chắc chắn là chỉ chạy được 1 chiều thôi. nó cùng một giá trị 5060 thì sao có thể thay đổi chiều được
@rinahernawati7956
@rinahernawati7956 3 года назад
Bsg
@AbdulHaseeb-pp2kb
@AbdulHaseeb-pp2kb Год назад
What is F00092 flag in p2p? where it is defined?
@cristian-gyozohaba8649
@cristian-gyozohaba8649 Год назад
It is a special relay of LS PLC corresponding to a clock of 200ms cycle.
Далее
🔥 SAMPLE: PLC LS XGB SERIES WITH MODBUS RTU
13:27
Просмотров 14 тыс.
Физика пасты Карбонара 🧪🔬
00:57
DVP 14SS2 "Modbus RTU" LS iG5A VFD
10:39
Просмотров 4,2 тыс.
LS HMI XGT Panel programming with Xp-Builder
28:14
Просмотров 49 тыс.
Modbus of LS with VFD (Motor Forward, reverse, stop)
8:21
Python Modbus
16:31
Просмотров 23 тыс.
SCADA Infou To PLC XGB LS Industrial System
14:38
Просмотров 8 тыс.
Физика пасты Карбонара 🧪🔬
00:57