Thanks for a very informative video as usual. Do you have any thoughts about directly connecting the current sense capacitor to sense+\- terminals? Converters that do direct resistive sensing have a built in diffamp which could be placed at your nodes S1 and S2, but I’m not sure if that would work in practice. I’m going to try it in a simulation but don’t trust it because I haven’t seen that sensing technique before. Also, how sensitive is the RC to RL matching to tolerance in practice? With 10%+ process variation in L,C and DCR before variations due to temperature and load I foresee sensing degradation or inaccuracy but I don’t know enough to make a determination. Thanks in advance for any help. You’ve already done more than I can ask!
Thank you professor! Interesting topic. However, one thing confused me. How is it possible to have circulating currents between power supplies output capacitors if there are ideal diodes in series with each output 24:40 ?
@@sambenyaakov Thank you sir ...could you please make a video on current mode control modelling of your switch inductance model and vorperian pwm switch model ,and then Ridley model ,after that Erickson model in Ltspice to get clear understanding of different models
So its up to 10W per unit . Are you looking for onePS with multiple outputs?The most important issue for the musical environment is noise consideration.
@@sambenyaakov It supplies low power but few outputs may supply 4W. Yes I'm looking to build it one unit with multiple outputs. You are correct about noise, and that's why I'm looking for isolated outputs. Thanks for your reply.