Тёмный

Current Transformer (CT) Nameplate Details Explaination 

Substation Testing and Commissioning
Подписаться 11 тыс.
Просмотров 33 тыс.
50% 1

Опубликовано:

 

22 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 21   
@bikrammandal2582
@bikrammandal2582 Год назад
Great information, thank you bro
@substationtestingandcommis3452
Recommended Videos: 1) Power Transformer Nameplate Details Explained in Hindi: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-6HrTgIOZC5k.html 2) Tan Delta testing of Current Tranformer (CT) : ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-iFWFyM3rhuo.html
@mahesh.gandham4193
@mahesh.gandham4193 3 месяца назад
Tanks sir for more information given through your video
@senthilm1582
@senthilm1582 3 месяца назад
Please tell How to calculate (Ith) Rated thermal short circuit current?
@biswajitbarik1937
@biswajitbarik1937 7 месяцев назад
Sir if rayed dyanamic current is 65.5KAP Then why short time current is only 26.2 which flow only 1 minute
@swapnad397
@swapnad397 2 года назад
Short time current means what..u said that RMS value of rated primary current that we did not get
@mahesh.gandham4193
@mahesh.gandham4193 3 месяца назад
1400(1-1-1) what is full form ct Tell me sir
@swapnilshiyaniya5306
@swapnilshiyaniya5306 Год назад
bhai esa kyu lag raha koi gunpoint pe aapke pass ye video shoot karva raha hai ?
@krishnakandel2402
@krishnakandel2402 Год назад
what is the ratio of weight of copper and core used?
@surendrakverma555
@surendrakverma555 4 года назад
Excellent. Thanks
@sarikajeswal6016
@sarikajeswal6016 2 года назад
very nice vdo
@swapnad397
@swapnad397 2 года назад
How parimary current and short time current related by using one example..
@siddeshaj552
@siddeshaj552 3 года назад
How to understanding example: 1250/1+1+1+1A 1600/1A like this ratio
@Sonu-snu
@Sonu-snu 3 года назад
great job bro...thanks a lot
@ashokar9135
@ashokar9135 4 года назад
Hi There, u gave me a gud information. Could you please let me know steps for selection of a CT for 33KV feeders 26MW of load.
@substationtestingandcommis3452
@substationtestingandcommis3452 4 года назад
For 33kV 26MW load, load current will be 454 Amp for pf=1. For pf=0.8, it would be 568Amp. So you can use a CT having ratio of 600/1. If 600/1 is not available, use 800/1.
@namessikander98
@namessikander98 2 года назад
May i know the formula please
@substationtestingandcommis3452
@substationtestingandcommis3452 2 года назад
I = P/( sqrt(3) * V * pf)
@maheshnayaka7757
@maheshnayaka7757 3 года назад
Super sir
@sharifhossain8830
@sharifhossain8830 2 года назад
Min Cpg?
Далее
How 3 Phase Power works: why 3 phases?
14:41
Просмотров 1,4 млн
What’s your height?🩷🙀💚
00:59
Просмотров 4,3 млн
Current Transformer (CT) Nameplate Details
14:03
Просмотров 5 тыс.
Current Transformers (CT)
14:31
Просмотров 498 тыс.