Brand : Daikin model : MKS80QVM ERROR : No error Symptom: Running after 45minutes,Fcu auto off and auto on back,outdoor LED 1 & 2 light up. Cause : Thermistor failure Symptom,thermistor short circuit. #bonmj #daikin #inverter
Hi Bon, could you please provide a source for many of the common manufacturers thermistor resistance/temperature values? I cannot find any for the LG brand.
That would be hard to find on the system unless its in cooling mode developing condensation at the time you are checking. Did the error code send you in the direction to check the thermistors? Last question did you full change the harness or just dry and seal the bad thermistor?
Just happen after running 45minutes. Only outdoor LED 1&2 on when stop running,indoor auto off and will auto on back after for awhile. We replace the new harness.
sir inverter daikin 1.5hp ,indoor fan motor stay in low speed what maybe the reason o the problem ? even we changes to high speed in the remote fan speed still low,thanks for the reply
Put in the water just show the thermistor is short circuit when water go in to the parts. When the thermistor locate at suction pipe,the water will go into the parts after gas pipe condensation.
Sir. My aircon.. cut in compressor n fan for 30min for 3 room. Is it thermistor of outdoor? I saw your ismike series, u change the indoor thermistor... May I know if is the same logic? Mine are toshiba
Hai sir ,vrv 3 Daikin system one outdoor 3 indoor ,all running good but , standard compressor Haven't run even one FCU haven't achieve room required temperature.please advise
Hello sir I am Aziz. I have a Daikin 1.5 ton inverter split AC. My AC is showing C3 error code. Can you please tell me what C3 error code is and how to solve it . Model no FTKZ50U