Della Mini Split AC Installation Step By Step 2024 | Total Installation 

SethCraft Workshop
Подписаться 14 тыс.
Просмотров 30 тыс.
50% 1

The Della Mini Split is easy to install and works great! This mini split is the 12,000 btu unit capable of cooling up to 550 square feed. The refrigerant is included in the outdoor unit. When installing this mini split you will need to pull a vacuum so that the copper lines will be filled. This unit runs as 27db with the silentmax system so the unit is very quiet. This Della mini split needs 240v power. It is nice to have the power and disconnect at the unit.
Mini Split website:
dellahome.com/...
Vacuum Pump on Amazon:
amzn.to/3VNi4z8
Adapter for mini split threads:
amzn.to/3xr5kq8
Plastic Pad for mini split:
amzn.to/45NgF0d
If you are looking for how to install a mini split this is the video for you. This diy mini split install is easier than you might think.
SethCraft is a participant in the Amazon Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to amazon.com

Опубликовано:

 

14 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 88   
@cranstjs
@cranstjs День назад
Update: Followed your lead with the pump, and I wasn't getting a vacuum to hold. So I tried the open the low pressure allen screw a little and lo and behold, that exposed a leak at the upper 3/8 fittings. Not torqued enough. Once I tightend that, you could hear the difference in the pump sound. Getting super cold air now! The soapy water didn't show anything. Very good video. I wasn't sure, because the manual shows using the insulated tape at the indoor unit to wrap all the way to the outdoor unit. Which imnplied taking off the initial foam that comes with it. In either case, I will leave that foam on and I will wrap the whole length with the insulating tape. The manual also discusses using appropriate torque when tighening the pipe nuts. 1/4" line; 13.3 to 248 ft lbs. 3/8" line: 22.1 to 25.8 ft lbs. And applying the putty to seal the tube at the wall on the outside. I also found it easier to connect and clamp the indoor unit wiring and then just snake the rest of the wire out the tube. Also, from my safety box for power, I used flex conduit with a flex conduit plastic fitting. The drain tubing, which is the same as was on my MrCool that I'm replacing, I can tell you will not hold up for long in the TX heat in the summer. Within 2 years, it was so brittle it just fell apart. Instead I got some 3/8" acrylic tubing from Home Depot, used pointy nose pliers to stretch the end some to fit snugly on the section coming out of the inside unit, that was still sound. That stuff can take a licking. I also found the wall plate, vs the MrCool version, is very delicate. When I put the indoor unit on it, the top right finger bent out about 1/4". The Mr. Cool uses about a 2 foot lip at the top that in the middle and very sturdy. So now I have to deside to I want to take it down again and add more screws to make it more sturdy. Or just leave it as is. It's not going any where and I might just leave well enough alone. In spite of the same rating as the MrCool 12k, the Della units are a lot lighter. The outside unit is much narrower and the inside unit is lighter and slightly smaller.
@rickyrichy5496
@rickyrichy5496 Месяц назад
I just finished the install of a 2 ton della mini split. And it works great, thanks to you my friend! When you come to LA, I’ll buy the tacos and the cervezas. Thank you sir
@sethcraftworkshop
@sethcraftworkshop Месяц назад
That's great news.Happy to hear the video was helpful. I'm looking forward to the tacos. Ha ha
@rickyrichy5496
@rickyrichy5496 Месяц назад
@@sethcraftworkshop let me know brother. It’s a legit invite
@stevekeith9854
@stevekeith9854 29 дней назад
I installed the 1800 btu unit iin my 20x30 shop in January. I'm very happy with it. I used a pvc downspout to cover the lines. Split it with a utility knife and you can spread it aesily and it will close right back up.
@aaronmizell
@aaronmizell 7 дней назад
Thanks so much for sharing!! Just installed our Della 18,000 btu mini split after watching your video multiple times and it is Awesome!! Thanks for going over everything so well! I did find out after I pulled a vacuum and made sure it was not leaking. It worked really well to just go ahead and disconnect the vacuum line before I let Freon into the line. It made absolutely no noise and let nothing in or out. Thanks Again!!😊
@sethcraftworkshop
@sethcraftworkshop 6 дней назад
Nice! I am happy to hear that the install went well. Sure is nice to have cool air in the heat of summer.
@jllaine
@jllaine Месяц назад
Thank you for a detailed installation, that was worth watching a longer than usual video.
@sethcraftworkshop
@sethcraftworkshop Месяц назад
Thank you for watching. This install was nice. The unit is working well.
@hakrhakir2357
@hakrhakir2357 Месяц назад
I was planning to do a split unit install, this came very handy.
@sethcraftworkshop
@sethcraftworkshop Месяц назад
Awesome! It is nice to have ac in the shop. Installing a mini split is not too bad.
@nicolasmuniz9452
@nicolasmuniz9452 Месяц назад
Just replaced a Pioneer 18000/18 seer with a Della 18000/22 seer, I could never get a response with Pioneer, bad evaporator motor, then fried board due to wires pinched at board door from factory, Della very well built, made Pioneer look like tin can junk, Della almost the size of a 24000 due to better seer rating, same price and a promo was in effect, WiFi and better remote functions.
@sethcraftworkshop
@sethcraftworkshop Месяц назад
I have heard from more than 1 person that pioneer is not great for communication. nice to hear that you got your della system installed and its working well.
@Jhpc399
@Jhpc399 Месяц назад
Very Nice one. Well done! all the way from Bulgaria
@sethcraftworkshop
@sethcraftworkshop Месяц назад
Thank you. This install sure has been nice for these hot summer days.
@philliphall5198
@philliphall5198 29 дней назад
I’m seeing more and more people doing there own ac work now and learning how to solider the connection on big homes units
@sethcraftworkshop
@sethcraftworkshop 28 дней назад
I bet it opens up a lot of mistakes but I like seeing people learn skills like this.
@mtay65
@mtay65 24 дня назад
Very well illustrated. Thanks, dude.
@sethcraftworkshop
@sethcraftworkshop 21 день назад
Thank you! I hope it helps.
@mikeharmon8733
@mikeharmon8733 Месяц назад
Why are you using soapy water to detect a VACUUM leak? There would be no bubbles, right?
@sethcraftworkshop
@sethcraftworkshop Месяц назад
The primary reason I use soapy water to detect a leak is because the instructions say to do so.
@Katana_00
@Katana_00 Месяц назад
You’re absolutely right. Bubbles would be detected after a positive pressure test with nitrogen. Obviously a vacuum would not produce bubbles.
@user-ud6mi8pp2b
@user-ud6mi8pp2b Месяц назад
He opened the valve for 5 seconds, so it would have pressure in the line.
@workbenchz
@workbenchz Месяц назад
Interesting that Della precharges the outdoor unit with enough refrigerant for the entire system and you needed to vacuum down the lineset.. The other one you did had a precharged lineset and both units. Did this give give you more or less confidence that the lines are free of contamination from the air?
@sethcraftworkshop
@sethcraftworkshop Месяц назад
The other unit was a mr. cool diy model. it did not require a vacuum at all. Both the indoor unit and outdoor unit both had refrigerant but so did the line-set. On this Della unit you have to have the vacuum to pull the refrigerant through the line-set. So far so good. it is running for well over a month with no issues.
@Houseb1859
@Houseb1859 26 дней назад
Why do you have to turn on the gas and check with soapy water? When the pipe is disconnected, the air conditioning gas escapes to the outside, which pollutes the environment. If the vacuum does not decrease within 30 minutes, the system is sealed!
@mikafoxx2717
@mikafoxx2717 22 дня назад
First off, this is the way you're trained to do it because if you remove the guage before releasing the gas you let air into the system instead which is much worse. This has zero ozone depletion so a tiny spurt of something thats got higher global warming potential is less bad than your day's driving to work. This is considered diminutive losses - you need to purge guages and other stuff with refrigerant in use but its far less bad than scrappers cutting open and relasing hundreds of pounds of gas a year - which is who the fines are really meant for.
@Houseb1859
@Houseb1859 22 дня назад
@@mikafoxx2717 You shouldn't do it like that in Europe. In addition, there is a loss of refrigerant in this way.
@mikafoxx2717
@mikafoxx2717 22 дня назад
@@Houseb1859 How do they do it in Europe then? Let air and condensate in and make the unit die three times faster? They use less harmful refrigerants while we still maintain stuff running R22. R32 is much better at only 675x CO2 and zero ozone depletion and R290 is legally ventable to atmosphere in any quantity because it's just 3X CO2. 1234yf is also like 1x.
@NSC3041
@NSC3041 13 дней назад
Mine didn't leak over 30 minutes but it did leak over 3 days
@johnisley4578
@johnisley4578 Месяц назад
Pro work, Good stuff.
@sethcraftworkshop
@sethcraftworkshop Месяц назад
Thank you. Its nice to have this mini split in the shop!
@cfife90
@cfife90 Месяц назад
What are you going to do with the excess? I ordered a 2 zone mini split from Della, and main floor is only about 8’ from where the outside unit will be.
@sethcraftworkshop
@sethcraftworkshop Месяц назад
My install location only gave around 2 feet of extra line. It will just be placed under the building. You will want to lay your extra line down horizontally if you are not going to cut it. Coiled but horizontal.
@markfolino6976
@markfolino6976 24 дня назад
Great video Seth
@sethcraftworkshop
@sethcraftworkshop 21 день назад
Thank you. This unit is working well.
@juanmaduro872
@juanmaduro872 Месяц назад
Thats is a good video i normaly i install those ac in 30 min it i work with allot of ac frome midea or gree
@sethcraftworkshop
@sethcraftworkshop Месяц назад
Thank you. Because of the video it took me a while to install but its not bad when not filming.
@unSTEVOED
@unSTEVOED 4 дня назад
Ive noticed a lot of people are using micron meters during the vac these days - is there a reason why you don't?
@sethcraftworkshop
@sethcraftworkshop 3 дня назад
I just followed the install manual. So far so good.
@wanaraz
@wanaraz 9 дней назад
When you make the bends with the copper do you just do it by hand? Thanks.
@sethcraftworkshop
@sethcraftworkshop 6 дней назад
Yes. The book shows how to hold the lines when you make the bends. This is to prevent kinking the tube.
@RealGenX
@RealGenX 9 дней назад
Thanks for the details!
@sethcraftworkshop
@sethcraftworkshop 9 дней назад
Happy to help!
@swamphox1
@swamphox1 Месяц назад
I have the same unit and about to install it. At 11:35 you pull down the tabs on the bracket and I don't see the purpose of these tabs. I don't see where they go into the inside wall unit. Can you please explain this?
@sethcraftworkshop
@sethcraftworkshop Месяц назад
(The manufacturer had me remove the clip showing these because one fell down.) They are only there to hold up the indoor unit while you install the electrical wires. The tabs do not hold the unit on the wall.
@nicolasmuniz9452
@nicolasmuniz9452 Месяц назад
I like to make new flares, also trim lines to size, I never really liked factory flares, usually kind of ragged.
@sethcraftworkshop
@sethcraftworkshop Месяц назад
New flares are nice. I do not have the tool for that.
@carltierman4202
@carltierman4202 29 дней назад
The compressor holds enough refrigerant for a 16' long refrigerant line. If you change the length of the line you need to compensate for either taken off some length of line or adding extra line. Mine came with 16' line. Others have 24' or other length of line
@EngineersHomestead
@EngineersHomestead Месяц назад
I've been debating which mini split to get for my 10x20 detached office shed (cathedral ceiling), got a few questions for you Seth: 1. Did you run 12ga wire? What size breaker? 2. Any reason for Della over something like Senville? I don't plan to buy DIY kits so will end up buying the pump and adapter like you. 3. Thoughts on 9k vs 12k btu for my space? I plan on going 240V model either way.
@sethcraftworkshop
@sethcraftworkshop Месяц назад
It is nice to have AC in the shop! 1. I ran 10/2 for the mini split. You should be fine with 12/2 for a 12,000btu unit. 2. Della seems like a nice unit. I have only used Della and Mr. Cool. I do not know about Senville. 3. The 12k has not had an issue keeping my 20x30 cool. If your place is smaller the 9k would work. many of the 9k are only 120v.
@jameszzh
@jameszzh 26 дней назад
Della is from TCL in China. Senville is form Media in China. As I know, both are good manufacturer. But Media is a little bit better in China and more qualified and more expensive.
@user-oy4qp9pq6i
@user-oy4qp9pq6i 21 день назад
@@jameszzhSome sites have reported that Senville builds Mr Cool and Pioneer.
@swamphox1
@swamphox1 Месяц назад
@sethcraftworkshop No help with the tabs? Really curious as to why they exist because they seem to serve no purpose and you pointed them out like they do.
@sethcraftworkshop
@sethcraftworkshop Месяц назад
Are you referring to the two metal tabs on the bracket? Those are designed to prop the unit up while you get the electrical work installed. I did not find them to be very helpful.
@swamphox1
@swamphox1 Месяц назад
@@sethcraftworkshop Yes, those are the ones and I get it now. There is nothing mentioned in the install manual. Just wanted to make sure they were not part of securing the unit. Nicely done instructional video BTW, very helpful.
@jameszzh
@jameszzh 26 дней назад
what is the diameter of the hole in the wall?
@JamesChandler-xl1mx
@JamesChandler-xl1mx 23 дня назад
On your gage lines. Do I need to remove the valve stem?
@sethcraftworkshop
@sethcraftworkshop 22 дня назад
Not on this one. Because I am not adding any refrigerant there is no need to remove the valve stem.
@rafhype3088
@rafhype3088 Месяц назад
could I connect this to a standard 110V indoor outlet? I can’t use a mini breaker outside
@sethcraftworkshop
@sethcraftworkshop Месяц назад
This particular mini split is for 240v. I believe the della unit that is 9000 btu is designed to ruin on 120v.
@jameszzh
@jameszzh 26 дней назад
you need to buy a 120v VERSION. Then, you can do it.
@ashtonalbritton8725
@ashtonalbritton8725 Месяц назад
So needle moved from -30 to right below 0. Is that an issue?
@sethcraftworkshop
@sethcraftworkshop Месяц назад
If your unit moved from -30 to 0 that means you have a poor connection on one of the lines. The vacuum was lost and the refrigerant will not stay in the line.
@ashtonalbritton8725
@ashtonalbritton8725 Месяц назад
@@sethcraftworkshop thank you for the reply! Yes I found the leak in the high pressure side. All good now!
@davidwoodall9308
@davidwoodall9308 Месяц назад
Why do you need an adapter to hook up the low side? Will the line from the vacuum pump just hook up correctly?
@Katana_00
@Katana_00 Месяц назад
Normal with mini-splits. Read up!
@sethcraftworkshop
@sethcraftworkshop Месяц назад
The thread size on the vacuum pump is not the same as the mini split. The adapter is required to make the connection. This type vacuum is designed for several uses.
@sethcraftworkshop
@sethcraftworkshop Месяц назад
Yes that is correct.
@tomtruong7432
@tomtruong7432 7 дней назад
The same vacuum pump you linked comes with the 5/16 female to 1/2 male adapter, is it just thread size that needs adaptation or is it something more?
@maxwelligwe1128
@maxwelligwe1128 Месяц назад
Mine is showing a P2 error message and not sure what to do. Not cooling and fan stops spinning
@sethcraftworkshop
@sethcraftworkshop Месяц назад
That error did not show up on my system. have you tried customer support?
@whowantstoknow8492
@whowantstoknow8492 22 дня назад
No nitrogen test ?
@sethcraftworkshop
@sethcraftworkshop 22 дня назад
I did not do a nitrogen test. Just followed the directions of the mini split.
@mdaljev1
@mdaljev1 28 дней назад
It is the same as mine, sold under Elit brand, but true is, this it TCL from China!
@sethcraftworkshop
@sethcraftworkshop 27 дней назад
Seems commonplace to have a rebranded unit from the same manufacturer. So far I am pleased with the mini split.
@jameszzh
@jameszzh 26 дней назад
I tried a lot to find who is the manufacturer, but failed. Thank you for this information.
@user-vt1ri1zk2v
@user-vt1ri1zk2v 23 дня назад
@@jameszzh the Della mini split has an I feel mode setting which is a Gree option on mini splits,so it most likely manufactured by Gree,the world largest manufacturer of air conditioners/mini splits and they are EXCELLENT units especially if you get the cold climate triple cylinder 2 stage compressor, the leader in the industry.Most mini splits(almost all) have parts made by Gree in them
@MarquisZellars
@MarquisZellars Месяц назад
Did you add any freon
@sethcraftworkshop
@sethcraftworkshop Месяц назад
This mini split has the refrigerant included within the outdoor unit. A vacuum is pulled and the refrigerant is released from the outdoor unit into the line set. Then the system is charged. No additional refrigerant is needed.
@buffalosoldier7360
@buffalosoldier7360 22 дня назад
Not a complete install shown, you left out the wiring at the breaker…
@sethcraftworkshop
@sethcraftworkshop 22 дня назад
It's beyond the scope of the install. That is more of an electrician thing. But it was simple. Just ran 240v out to a switch.
@bonexsher
@bonexsher Месяц назад
hurts my eyes to look at this 😪
@sethcraftworkshop
@sethcraftworkshop Месяц назад
Was it like a bug to a zapper? lol
@Katana_00
@Katana_00 Месяц назад
Why? What went wrong other than bubble test.?
@eb1888.
@eb1888. 13 дней назад
You edit out all the minor installation difficulties anyone doing this will encounter. This deletes your solutions and possibly attempts. That footage would be the most important for a person doing this for the first and likely only time. You had all that important info. Your video has much less value.
@sethcraftworkshop
@sethcraftworkshop 13 дней назад
This was my first install of a mini split that required a vacuum. The only things that I removed from the video were the filler bits. There really were no issues with the install. The value of the video is still high. (I have been building things for 13 years so perhaps I have more install history than some people but the mini split was not hard.)
@FOODONTRUCK
@FOODONTRUCK 6 дней назад
​@@sethcraftworkshop we installed a della 9000 btu last week and did not vacuum pump😒😒🤦‍♂️🤦‍♂️ indoor unit know leaks 🤦‍♂️🤦‍♂️🤦‍♂️ can we still pull a pump on it or not ????
Далее
Insane Coffee trick EXPOSED 😱☕️ #shorts
00:20
Просмотров 3,7 млн
DIY Mini Split Aircon Installation
6:38
Просмотров 1,7 тыс.
#1 Reason Why DUCTLESS Units Fail | How I Fix It...
13:59
Watch This Before You Buy a Mr Cool Mini Split
35:24
Просмотров 186 тыс.
Multi-zone split type Air Conditioner installation
16:49
ROCKET that LITERALLY BURNS WATER as FUEL
19:00
Просмотров 2,2 млн