Happy Teachers Day 😇🙏 Finally Passed My B.E Civil And I was worried about ddrcs but your lectures helped me to score good Thankyou For this really grateful ♥️♥️
Good explaination. Found some mistakes in vertical stem. Considered 20mm dia for deff provided Y16@115c/c also it should be Y20@180 C/C. In case temperature steel. Considered 8mm dia but detailed as Y10@320 C/C and Y10@450 C/C not shown properly. Distribution on inner face not shown. Hope you can recheck and correct. Any examples on considering surcharge on Retaining wall. Excluding inclined earth fill.
Sir aapka video bahut accha laga bs ek step samajh nahi aaya Step 7 mai aapne check for stability against sliding Kiya hai jisme resisting force (mu*summation w) Kiya toh isme (Pa) ka vertical component add kyo nahi kiya.
why have you taken moment about heel? shouldnt you be taking moment about toe since the structure will rotate about that point? Also the formula for Passive earth pressure coefficient for inclined backfill is different. the one you used is for uninclined backfill
Sir minimum spacing last last 300mm taak hi rehta hai na?? Spacing ka check nhi lagta h kya Step no 13 mai apne spacing 450 liya hai inner face mai So sir please clear my doubt Thank you 😊
Muje batao ki ek irrgation canal per retaining wall Jo hoti hai uska bed ore ground level kahan hota hai Kiyunki jub hum usse rate denge to pata chale ki above the ground level1.2m se rate plinth level ki rate or four five level rate usse upper please show me ground level or NSL and bed level of the retaining wall