Design of Column for Three Storey Building Practical Video 

Civil Engineers
Подписаться 904 тыс.
Просмотров 1 млн
50% 1

1) Construction cost of 1000 square feet House 2019? Cost of House Construction per square foot 2019
• Construction cost of 1...
2) Grade Of Concrete and water Cement Ratio
• Grade Of Concrete and ...
3) How to calculate Cement, Sand, and Aggregate for M20 concrete
• How to calculate Cemen...
4) Depth of Footing/Foundation and Reinforcement details in Foundation
• Depth of Footing/Found...
5) Maximum distance between two RCC columns?
• Maximum distance betwe...
6) Big Mistakes in RCC Slab - Lapping Mistakes
• Big Mistakes in RCC Sl...
play Lists :
Construction Videos :
• How to Chose Good Qual...
Construction Site Visit :
• New Exterior Design fo...
House Planning Play List :
• How to Study Column wi...
#CivilEngineers #CivilEngineering

Опубликовано:

 

10 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 136   
@qualitybuilders569
@qualitybuilders569 3 года назад
These columns can bear 5 stories, The column design is over specified Its is not economical also design should make as per thickness of walls like 8x18 inch or 8x24 inch would be much better.
@Deepakyadav-jk5km
@Deepakyadav-jk5km 3 года назад
You're right and he is right too, this column can hold 5-6 floor easily in resident building but as he said this one is for commercial building which mean live load is many times higher than the resident's live load so 3 floor in commercial is easily equal to 5 floor in resident
@valentinovictor
@valentinovictor 3 года назад
Rightly said, too much usage of steel for 3 storey building, even if it's commercial this specification has been exaggerated
@valentinovictor
@valentinovictor 3 года назад
@@Deepakyadav-jk5km if the span distance between two columns is higher , then it's acceptable or reasonable to add number of steel rods, but looking at the site the columns are closely arranged and the rooms are not that bigger. Not a proper design
@Deepakyadav-jk5km
@Deepakyadav-jk5km 3 года назад
@@valentinovictor what if they have to put tonns of metal ore in it, all the theories is worthless in commercial everything should be extra
@tumusiimejohn1089
@tumusiimejohn1089 Год назад
Liked all arguments you guys. Very educative to us beginners. Thanks
@muralikrishna5435
@muralikrishna5435 3 года назад
It will be much better if the bottom of plinthbeam atleast 3inches below ground level to avoid seepage of water into basement during heavy rain and the entry of rats through bottom of beam
@rogernbackyard6677
@rogernbackyard6677 Год назад
Thanks for sharing sir and this vedio...new friend from Phillipines
@krishna_raj9331
@krishna_raj9331 2 года назад
Hello sir, Are 12 mm 4 bars and 10 mm 2 bars enough in a 9*15 column..? The column to column distance is 15 feet. How many storeys can be built with this much reinforcement..?
@aamirsingh3351
@aamirsingh3351 3 года назад
I'm just a random guy but I can see all the rebars are cut at same height . Is this acceptable ?
@sanjayhs5301
@sanjayhs5301 3 года назад
No... it's not acceptable...
@valentinovictor
@valentinovictor 3 года назад
Using 20mm rods, that too for 12 numbers, is way too much , not a feasible cost effective design
@dhaneshwarv8649
@dhaneshwarv8649 3 года назад
Yes bro 16mm with 12nos is more then enough
@johnbahame1023
@johnbahame1023 3 года назад
Over designed column
@kgmanjunatha4849
@kgmanjunatha4849 2 года назад
For G+2 6 no 16 mm is sufficient
@kwabsmundi4395
@kwabsmundi4395 2 года назад
@@kgmanjunatha4849 what about G+3
@waqastv7862
@waqastv7862 3 года назад
Sir this plinth beam alignment out not proper work because plinth beam is zigzag?
@KoromaAlhajiSheiku
@KoromaAlhajiSheiku Месяц назад
Is this same reinforcement continue to the last floor
@jayareddy6252
@jayareddy6252 Год назад
It is very useful for common peoples. Jayachandrareddy
@krishnaommi691
@krishnaommi691 3 года назад
I am using 9 X 18 column size distance between two columns 20feet .. so which size using beams and bars
@somalia5019
@somalia5019 8 месяцев назад
New subscribed from Somalia
@mohmmadjeyaurrahman8105
@mohmmadjeyaurrahman8105 3 года назад
Assalamo alaikum I made a structural design of 3 storey domestic building as per IS code in my design column size is 230*230 with 16mm 4 baar and bindup it with 8 mm ties by calculation it can bear the load so it's right or not please comment Thank you
@qualitybuilders569
@qualitybuilders569 3 года назад
23x45 would have been much better
@makistar4855
@makistar4855 2 года назад
Are 8 bar use krte bro
@shrayanshjha8109
@shrayanshjha8109 3 года назад
I am using 9" X 15" column for 19 feet horizontal span So What can be the distance between two column vertical span for G+2 building
@shrayanshjha8109
@shrayanshjha8109 3 года назад
16mm - 4bars 12mm-4bars
@erkundanyadav
@erkundanyadav 3 года назад
Steel percentage should be maintained
@devapratimbaishya
@devapratimbaishya 2 года назад
What is your beam size?
@shrayanshjha8109
@shrayanshjha8109 2 года назад
@@devapratimbaishya 9 x 15 inch
@devapratimbaishya
@devapratimbaishya 2 года назад
@@shrayanshjha8109 it's fine , where are you from?
@mickhailrapang7316
@mickhailrapang7316 8 месяцев назад
What about the iron for the floor where it is tied... Sorry I just learned
@nasirahmed5091
@nasirahmed5091 Год назад
Thanks for beautiful information
@hokughazhimomi2835
@hokughazhimomi2835 3 года назад
I want to have 15 feer distance from column to column or( 16 feet center to center of column), using 9"x15" size column. 1 is it OK? 2. What size and number of steel bars are advised?
@goldenera9458
@goldenera9458 3 года назад
same question
@jyot3950
@jyot3950 3 года назад
If there is one basement one ground and 4 more stories,total 6 then what should be the column beam structure
@madhurisurajbharath3634
@madhurisurajbharath3634 2 года назад
Sir iron will get rust , after some years. Can we use steel instead of iron for pillars.. .
@bickyrajkumar3545
@bickyrajkumar3545 3 года назад
3 storey building heavy steel bar therw is no diamond stirup
@21stcenturyworldsystem46
@21stcenturyworldsystem46 Год назад
Very knowledgeable video. Thanks
@user-sq7cq6pn1b
@user-sq7cq6pn1b Год назад
Dear, How do I buil G+2 Building using 9"x12" column size
@BLNBorey
@BLNBorey 2 года назад
Good job I love Civil Engineer
@meiyalaganc3204
@meiyalaganc3204 2 года назад
Could you please share the video of this building current status… completed building video… thanks
@halonaoba8827
@halonaoba8827 3 года назад
Sir i want to know about septic tank for house best
@praveensm223
@praveensm223 3 года назад
ಈಶಾಣ್ಯ ಮೂಲೆ
@migustoes5089
@migustoes5089 Год назад
What about if I need Reinforcement columns? The measurements will be the same?
@sajjadrehmani7439
@sajjadrehmani7439 11 месяцев назад
sir how distance in 2 coulumn in three story buillding you prefferd. plz reply
@uddinhelal5392
@uddinhelal5392 3 года назад
Very good explain.
@Mike-dm2og
@Mike-dm2og 3 года назад
Jazzakallah Khairan brother
@phyohtetkoko929
@phyohtetkoko929 2 года назад
Thanks For Teaching Sir
@vikasjha6829
@vikasjha6829 2 года назад
Sir 1200 sq ft m ghar bnana h mujhe..3 manjil building bnane k liye pillar ka size 10"x10" de skte h with 6 rods of 12 mm. Distance between two pillars is 10 feet.. Total 12 pillars h.. Please mera reply kre ❤💯🙏🏼🙏🏼🙏🏼🙏🏼
@swamygaddam199
@swamygaddam199 8 дней назад
16 is better
@nobertsyriaque6727
@nobertsyriaque6727 3 года назад
What is the size of footing and steel reinforcement details.
@goldenera9458
@goldenera9458 3 года назад
same question
@makistar4855
@makistar4855 2 года назад
Sir in my house contractor is using 20 columns but in 6 columns span is 18.5 feet, 19 feet. Is column spain is right. Column size is 9×14 and bars used are 16 bars. 16 mm are 4 bars and 12 mm are 2 bars. And plinth beam size is 9×18 can I go for G+2 with this structure
@er.sarikarajput6392
@er.sarikarajput6392 Год назад
you can...
@shahidmunir4917
@shahidmunir4917 Год назад
Hello mr civil engineering where is the footing of colum???very big mistake....he is not a civil engineer.....
@bilalchohan8761
@bilalchohan8761 3 года назад
Sir why the Brickwork foundations nearly plot too much deep where you use third class brick?
@malakand1656
@malakand1656 3 месяца назад
Dy column da pasa beem size ba sa razi
@robertswanson6774
@robertswanson6774 2 года назад
Sir what is your distance from one column to the other?
@buiding_your_trust
@buiding_your_trust 2 года назад
18ft
@askarkhan263
@askarkhan263 3 года назад
Wow that's nice job and good work
@Kpraveen1407
@Kpraveen1407 Год назад
Latak Beem kitne inch ka hoga our Rencforment kya hogi
@abmsiddiqui007
@abmsiddiqui007 7 месяцев назад
fine
@j6pluskusnandar265
@j6pluskusnandar265 3 года назад
Waalaikum Salam warohmatullohi Waabaraqatuu🙏🙏🇮🇩
@sankarmegavath6265
@sankarmegavath6265 Год назад
Sir, between coloum Max allowed length please
@julianamyrthong1263
@julianamyrthong1263 3 года назад
Please explain about domestic building
@mahbubalam2584
@mahbubalam2584 3 года назад
Sir it is learning of construction process. So this is not structure or column design learning or thiury.
@anwartalha3048
@anwartalha3048 3 года назад
Sir can I make colomn in plinth beam?if not make in foundation for 2 storey house?
@elviraandadi1985
@elviraandadi1985 9 месяцев назад
what is the column size
@joelrosales6359
@joelrosales6359 Год назад
Notice no construction joints for beams and columns.
@Fundamental_Gospel
@Fundamental_Gospel 3 года назад
Sir, you are very sincere!👍
@engpk7211
@engpk7211 Год назад
Number of bars and column sizes way too beyond required standards depending on floor loadings and number of floors
@muhammedibrahim450
@muhammedibrahim450 11 месяцев назад
It's good. Keep it up.
@AungThein-zh7cj
@AungThein-zh7cj Год назад
Verygood
@sameersinghyadav5645
@sameersinghyadav5645 2 года назад
Nice and informative
@dohdolla1704
@dohdolla1704 Год назад
What is an inch in technology
@mathskind
@mathskind 2 года назад
I want have column Rings grape 7 inchee with 20 mm 4 bar n 2 piece 16 mm
@AtaurRahman-lw3pp
@AtaurRahman-lw3pp Год назад
Total rod how much per sqft
@Inspireme211
@Inspireme211 3 года назад
What is size of plinth beam
@erkundanyadav
@erkundanyadav 3 года назад
Perfect
@uniquerahman9887
@uniquerahman9887 3 года назад
Good job
@kindisaac5008
@kindisaac5008 Год назад
I love tutoring I hope I will contact you someday
@riqueldelcopete6504
@riqueldelcopete6504 3 года назад
Hola amigo sebe una estructura muy bien y fuerte como para hacer 5 o 6 alturas 🇪🇸👍💪
@muhammadadil6183
@muhammadadil6183 2 года назад
Beam boht zeyada day deye hain ap nay.... Kam b day saktay thay
@probathsangma5951
@probathsangma5951 2 года назад
Sir from the starting show
@NdyMv24
@NdyMv24 Год назад
Sloof & tiang coloum nya ukuran berapa ini ?
@rameshak5268
@rameshak5268 2 года назад
Sir, distance b/w two columns 18ft, and column 9*12inch, pl suggest sillbeam, rcc and beam reinforcement details, construction area 30*40 ft (can I send plan sir)
@rahulbisht3838
@rahulbisht3838 Год назад
For 18ft distance you could've used 12*12 inches column size
@deleted1070
@deleted1070 3 года назад
Footing dept ?
@qualitybuilders569
@qualitybuilders569 3 года назад
16mm Longitudinal would have been enough
@AlamKhan-hg4fn
@AlamKhan-hg4fn Год назад
سٹیل کے ساتھ جو کنکریٹ لگی ہوئی ہے اس کی صفائی بہت زیادہ ضروری ہے
@truesolution6069
@truesolution6069 5 месяцев назад
What are byou doing? Do you understand what you do?
@debasisdas5696
@debasisdas5696 3 года назад
Sir I want to know about colum size, beam size and depth of footing for two storey house
@debasisdas5696
@debasisdas5696 3 года назад
Add a video for two storey house
@SuperCOLDRICE
@SuperCOLDRICE 3 года назад
Perfect job
@user-cb5mi3qq8m
@user-cb5mi3qq8m 2 месяца назад
Detail grade beam
@sadhubaba789
@sadhubaba789 Год назад
No dpc work for ground
@sukumarghosh1195
@sukumarghosh1195 2 года назад
Centre to centre distance between columns not given
@simluong1290
@simluong1290 3 года назад
Quá chắc, xây bao nhiêu tầng hả cụ
@jotamanroka7226
@jotamanroka7226 3 года назад
Hight of column from plinth beam.pls mention sir,,,🙏🙏🙏🙏
@pavanagarwal9167
@pavanagarwal9167 3 года назад
My contractor has give 25feet distance between two pillars. He has used 9x18 pillar size with 8 pieces of 16mm tmt bars. Beam size is given as 9x24 with 6 pieces of 20mm bars. It is a G+2 residential building. Is it ok ?
@justmusz6530
@justmusz6530 2 года назад
My contractor has also used 16mm x8 for the pillars. I want to know if it's OK. (3 story building)
@surendersharma3879
@surendersharma3879 Год назад
No
@perfectopadillajr3452
@perfectopadillajr3452 Год назад
Thumbs rule: Never make decision on how big and how many bars to use for your house/building if you are not a trained structural designer. Buildings are most likely different from each other. Hire a prof structural engineer, be safe and save money.
@engpk7211
@engpk7211 Год назад
True. Safety and economy all on par
@wawannazar2275
@wawannazar2275 Год назад
So if you cant pay prof engineer, you cant built a house. You know prof engineers are not cheap these day.
@mageinteriors3012
@mageinteriors3012 Год назад
@@wawannazar2275 what you save for prof engr you make up for the bars... 🙂 in any case, bear in mind safety always comes a priority
@alinsorohan
@alinsorohan Год назад
The reinforcement is ok.. but the brick foundation. I'm scepticle
@baiduibrahim6424
@baiduibrahim6424 3 года назад
Why do you bend those hooks at 135°
@kgmanjunatha4849
@kgmanjunatha4849 2 года назад
It can bear more load & Stable than 90° bent hooks
@aifiama5881
@aifiama5881 3 года назад
What about the beam
@anishanishkt5284
@anishanishkt5284 3 года назад
Please details of steel in beam
@engrrahamsher6162
@engrrahamsher6162 3 года назад
Lap zone in column should be the middle portion
@harishkumarsharishkumars848
@harishkumarsharishkumars848 3 года назад
Column size
@Kse1010
@Kse1010 Год назад
Who r u addressing???
@asiffarsifitingkolhapur6820
Hi
@hikmatkhan3385
@hikmatkhan3385 3 года назад
sir also made video in pashto please
@probathsangma5951
@probathsangma5951 Год назад
Fromm the beginning make a video I mean from foundation
@titde1961
@titde1961 2 года назад
these are not 20mm!!
@joshuaterrado9654
@joshuaterrado9654 2 года назад
Terrado family share
@sonofman8262
@sonofman8262 Год назад
Vertical !
@kulijowo8273
@kulijowo8273 Год назад
Ok
@mjshafi5311
@mjshafi5311 2 года назад
Waleakum aslam
@valentinovictor
@valentinovictor 3 года назад
Too much usage of steel, which only increases the cost
@maskepo99
@maskepo99 Год назад
👍👍🙏🙏🙏
@julsvlogtv1991
@julsvlogtv1991 2 года назад
👍👍👍❤
@user-xh3hj8cl8z
@user-xh3hj8cl8z Год назад
5/tr
@Molanan4
@Molanan4 3 года назад
gulami wali zuban mat
@Sarojkumar-xe2qi
@Sarojkumar-xe2qi Год назад
Speak in Hindi
@sukasunnah
@sukasunnah 3 года назад
Sir can you added subtitle
@SabirAli-dm8zj
@SabirAli-dm8zj 3 года назад
😥😥
@JaveedKhan-sn6qz
@JaveedKhan-sn6qz 3 года назад
Bakwas band karu eay 3 floor calculation nahy hy
Далее
House construction process step by step
24:09
Просмотров 1,9 млн
Вопрос Ребром - Булкин
59:32
Просмотров 690 тыс.
Two Way Slab Reinforcement
9:08
Просмотров 921 тыс.
COMMON MISTAKES IN CONSTRUCTION - PART 1
14:27
Просмотров 2,1 млн
Вопрос Ребром - Булкин
59:32
Просмотров 690 тыс.