hii, salammualaiku brother, I'm using 3phase, 100kva gen set, also got 2 batteries (150ahx2) , can u suggest me an betery static charge... and how many amp is suitable for 150x 2 ah.. wassalam brother
Hi sir I got a problem if the genset keep on drained a battery or always when it need to start up automatically when on standby the battery is flat need to be jumped start first before the engine start what could be the problem
Hi our using cumins generator using charger not working properly checked found that transformar out 38v ac after that wire going heat sink out not coming please how to check
Sir, where is the positive from the charger going? I mean if the generator starts, does the charger will cut its charging? Because the alternator will now be the one to charge the battery. How it is done? Is there like a relay that will cut the connection? Thank you so much for your video.
Hello sir , i need help regarding battery changing in our gen set , our system is connected with ATS , when we changing the batteries mean remove the terminal Ats is shutdown the mean supply . We closed all control breaker etc .
Hello sir salama alekom . I'm working in a company where they need this kind of charger can u help me out as I'm listing for you what's our specifications. Our line input is 3 phase 380v with 60hz and output is 24v 12A . We purchased a 2 big batteries 12v 200Ah (20HR), 400MIN (RC) /ICC 1150 A. Can you please help me choose the right battery charger
Hello again Sir, good day! Just want to ask, the static charger of one of our generator was damaged. We have a battery charger with 24A capacity "Panther". Can i use it? I will connect it directly to the batteries outside so that it will charge. For the controller, will not it affect? Thank you.
@@DieselGeneratortraining thank you sir, my company here in philippines buy a used generator and then repair after make a rentals they have 800kva perkins genset no alternator,
Hello Sir good day. I noticed that our generator cannot start when we only use 2 batteries in series. It can only be started when there will be two 24v in parallel. Also, the voltage greatly drops during start up that is why it cannot maintain the voltage unless when using parallel. What could be the reason? The batteries are all new. Thank you.
Okay Sir, i'll check on the cummins manufacturer. For now, the batteries were continuously charged by the static charger. Thank you. I'll check again tomorrow. Thank you for your support.
1. Dse 7320 full course video tutorial lnkd.in/dCPHvrk 2. How to read Electrical Drawings Video tutorial lnkd.in/g8v6BEG 3.how to bypass generator AVR lnkd.in/dP6Xn-Kd 4. Three phase genrator excitation system video tutorial lnkd.in/dE8ZDz3 #generator #dieselgenerator #generators #Electricgenerator #electricalengineering #electricalengineers #Engineering #Electrical #techjobs #technicalsupport