Diagnosing A Generator That Has No Power Output. 

TheDIYGuyDOTnet
Подписаться 57 тыс.
Просмотров 687 тыс.
50% 1

For more information or a written out step by step you can stop by www.thediyguy.net/2012/11/how-... We will be showing you how to diagnose a generator that has no power output to see if its your automatic voltage regulator is bad and needs replacing or if its the part that generates the electricity.

Опубликовано:

 

11 ноя 2012

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 46   
@genemyersmyers6710
@genemyersmyers6710 Год назад
That was prfectly clear and very helpful .
@AirikYT
@AirikYT 2 года назад
My AVR vibrated loose in about 5 seconds of run time and melted to the bearing housing, thanks for the help. 👍
@dj5752
@dj5752 4 года назад
Nice job. Thanks.
@houghbruce
@houghbruce 4 года назад
I have flashed my generator which has been unused for multiple years. I now have between 39 and 42 volts when I test the two wires disconnected from the AVR. I do not see a capacitor. My generator looks almost identical to the one in this video, except it is labeled Briggs n Stratton XL 8000.
@TheDIYGuyDOTnet
@TheDIYGuyDOTnet 11 лет назад
Your welcome, glad we could help and save you a trip to the repair shop.
@dorism.7026
@dorism.7026 5 лет назад
Thanks Very Helpful
@TheDIYGuyDOTnet
@TheDIYGuyDOTnet 5 лет назад
You're welcome, Glad we could help. Thanks for watching.
@rodcollins2978
@rodcollins2978 3 года назад
Hi I have a power max 1300w generator, motor runs okay but as soon as a power tool (500w) is switched on it stalls the motor even if I manually keep revs up thanks
@edlewandowski1867
@edlewandowski1867 10 лет назад
I have the older style AVR where would I check for voltage? Right at the outlet on the control panel?
@TheDIYGuyDOTnet
@TheDIYGuyDOTnet 10 лет назад
It will be the same wires going to the AVR. Yours should just have the black inline booster.
@codyreber1936
@codyreber1936 5 лет назад
Hi im having a problem with my generator and i did the things you said and im getting around 106v does that mean the avr is good or bad thanks?
@TheDIYGuyDOTnet
@TheDIYGuyDOTnet 5 лет назад
Most low voltage conditions on generators are simply due to a low engine rpm. So your engine rpm should theoretically run @ around 3600 rpm which will produce 120/240 volts @ 60 HZ. So when you applied 12 volts into it you got 60 volts when testing? It also could be a bad capacity which will result in a low voltage reading from the generator as the power being generated will be from the residual magnetism of the rotor (usually about 2-5V). To test a capacitor, a multi-meter that can test capacitance is required. To test a capacitor, it must first be removed from the generator and discharged. Be careful when removing the wire leads that a short is not created across the capacitors terminals. (Videos out there on how to discharge a capacitor. Some just say use a screwdriver with an insulated handle to cross the terminals on the capacitor (this will result in a loud pop and a spark). Once discharged, take a reading from the capacitor. The measured capacitance should be +/-5uf of the specified rating printed on the side of the capacitor. If not, the capacitor should be replaced.
@lindamartin5337
@lindamartin5337 6 лет назад
Have a generator where only one half of the outlet works, replaced outlet but no luck, any helpful hints to repair?
@TheDIYGuyDOTnet
@TheDIYGuyDOTnet 6 лет назад
What make generator and modelis it? is it 110 volt only or a 220 volt? Does it have a switch to change from 110 v to 220 v if so check that switch. Also check the circuit breakers or reset buttons to ensure there not tripped. Is the GIF reset on the outlet? I'm guessing your talking about a 110 volt plug that either the top or bottom half works. When you replaced the outlet did it have 2 or 4 wires going into it? All the other plugs work?
@lindamartin5337
@lindamartin5337 6 лет назад
The generator is a Coleman Powermate PM0543000.01. No switches to switch between a 110v and a 220v. The circuit breakers nor reset buttons have been tripped. Yes a 110v plug and one side does not work. The new plug that I replaced it with is the same, 4 wire. The generator only has one double outlet totally. Any help would be appreciated as it is new, but was not taken out of the box for quite a few years. Just puzzled why one side of the out let works and the other end doesn't. The receptacle is a 120 v, 20 ampere duplex receptacle.
@TheDIYGuyDOTnet
@TheDIYGuyDOTnet 6 лет назад
So since it has been sitting it may have lost its residual magnetism on one leg. So lets try and "flash" that side and see if that works. So what you will want to do is start the generator let it run for a minute or so and then grab a CORDED drill. Plug it into the NON working outlet. Make sure the drill is in the forward position/ going in the forward direction and then squeeze the trigger on the drill and spin the head of the drill backwards 5 or so times then let go of the trigger for the drill wait 5 seconds or so and then pull the trigger on the drill and see if it works.
@rcmoot
@rcmoot 10 лет назад
you did not say if you just hook the negative wire up for seconds or about a minute while engine running , then check for ac volts out on the two wires. if it has ac output on the two wires ,shouldn't it read 110 vlts instead of 60 vlts?
@TheDIYGuyDOTnet
@TheDIYGuyDOTnet 10 лет назад
You want to start the generator and let the engine idle/ speed stabilize and then hook the Negative lead to the battery for the entire time while testing the two wires. So to recap generator running stable engine idle, then hook up negative lead to the battery, then test the two wires, unhook negative lead from battery and then shut off generator. You want to have a min of 60vlts. Those 60vlts would go to the AVR where it boosts up the excitation to the field of the generator to maintain the terminal voltage. 120v / 220v.
@heimer4
@heimer4 3 месяца назад
I did exactly what you said but to a generac 3500XL model 09441-2 and I only got 30 volts. That means my power head is fried huh? I accidentally turned the main from the road back on before turning off the generator. I have been hooking and unhooking it up to my home for years and for some reason I had a brain fart.
@sshawn09
@sshawn09 4 года назад
Have you had a case where you flash the genny, boom it produces electric, shut down 30 min later, 2 min more start up and no juice again? What could cause that? 2011 blackmax 8750
@emmanuelmusakanya1764
@emmanuelmusakanya1764 2 года назад
3 phase diesel Gen set starts vibrating whenever you load it .
@unquiche
@unquiche 5 лет назад
"Alligator clip"? I saw some push-on terminals, but no alligator clips.
@TheDIYGuyDOTnet
@TheDIYGuyDOTnet 5 лет назад
Ya I had some push on clips for another project so I used those instead of alligator clips. You can use either but I figured more people would have alligator clips rather then push on clips or the female spade connectors.
@nationstates7699
@nationstates7699 4 года назад
Did it confuse you?
@dagnachewdagne1452
@dagnachewdagne1452 6 лет назад
For how long we boost with 12v dc?
@TheDIYGuyDOTnet
@TheDIYGuyDOTnet 6 лет назад
For as long as it takes you to test the wires with the volt meter.
@patrickdakwa8049
@patrickdakwa8049 6 лет назад
My Kohler Marine diesel engine keeps giving me low voltage and shuts down within a short while. What do I do
@TheDIYGuyDOTnet
@TheDIYGuyDOTnet 6 лет назад
Proper level of oil in it? It could be a bad low oil cut of off switch. Not sure if it has a high level coolant cut off switch as well which if they coolant gets to hot will also shut it off. I am not sure what the proper RPMs for that generator is supposed to be.. If its not running at the correct RPM's it will give you low voltage.
@chadmcgovney2721
@chadmcgovney2721 10 лет назад
Shouldn't you try and flash the generator first? Then go through the fun part of doing as this video states?
@rottmanthan
@rottmanthan 6 лет назад
ya that's what I would do.
@rippetob
@rippetob 8 лет назад
I have a homelite lr5000t that has no output power any ideas on how to fix it
@TheDIYGuyDOTnet
@TheDIYGuyDOTnet 8 лет назад
You can try "Flashing the generator" if that doesn't do it, it could be a "faulty diode" if you google either one it will give you an idea on how to flash / replace that riode
@rippetob
@rippetob 8 лет назад
+TheDIYGuyDOTnet I tried that with a drill but no luck
@jimmyjones7549
@jimmyjones7549 7 лет назад
TheDIYGuyDOTnet
@Poochie43124312
@Poochie43124312 9 лет назад
thanks cool video
@jbsnarayana4938
@jbsnarayana4938 11 месяцев назад
Quick shipping, beautiful unit, easy to use
@paulthomas2426
@paulthomas2426 8 лет назад
OK, so I have a 6,500 KW Diesel brushless enclosed generator that has an external AVR. Engine runs fine but now power is being generated. Since I cannot remove the two wires off of the rotors where and how do I hook up an external 12 volt battery prior to testing the tow wires coming off the AVR?
@TheDIYGuyDOTnet
@TheDIYGuyDOTnet 8 лет назад
+Paul Thomas That is the 12v battery method. You can try the electric drill Method.. Plug in an electric drill into the generator receptacle, If the drill is reversible, move the direction switch to the forward position next Start the generator. While depressing the trigger on the drill, spin the drill chuck in reverse direction. This will excite the field and the generator will now produce electricity. If spinning the chuck one direction does not work, try spinning the chuck in the other direction as you may have the reverse switch positioned backwards. Use caution not to get your hand or other materials caught in the chuck. As soon as the field is excited, the generator will produce power and the drill will turn on. The reason this works is because the electric motor in the drill will act as a small generator when spun backwards. The magnets in the drill's motor induce a voltage into the motor windings, which is fed back through the trigger, cord and into the generator receptacle. From there it goes into the power winding of the stator. The voltage going through the power winding creates a magnetic field, which is intensified due to the iron core of the stator laminations. The rotor intersects this magnetic field as it is spun past the power winding, thus inducing a voltage in the rotor winding. Once current flow is present in the rotor winding the rotor has been flashed.
@markmbpollock4330
@markmbpollock4330 5 лет назад
TheDIYGuyDOTnet .
@jbodden6977
@jbodden6977 2 года назад
we found the brushes damaged, but the four 'main leads' are all grounded together, this seems wrong somehow...
@malaekahana1
@malaekahana1 3 года назад
. RU-vid & Google Ads Are So Full Of Bull Shit, : ( & U Get All THE SPAM
@esmartdavis7722
@esmartdavis7722 8 месяцев назад
New generator my foot. Why u gone all there so fast.?
@stephenkonowal1956
@stephenkonowal1956 3 года назад
9
@ebberjr3924
@ebberjr3924 3 года назад
You obviously know what you are talking about but please slow down a little on your next one & be a little more specific for us beginners.
Далее
How an Alternator Works: The Ultimate Guide
10:55
Просмотров 176 тыс.
7 Reasons Your Generator Is NOT Producing Power!
5:28
Просмотров 159 тыс.
22 Useful Tips And Tricks That Work Extremely Well
18:05
Building a Generator
12:36
Просмотров 1,2 млн
Battery-Powered Magnetron
14:48
Просмотров 583 тыс.