Double Mesh in Slab Practical video on Site 

Civil Engineers
Подписаться 899 тыс.
Просмотров 60 тыс.
50% 1

Опубликовано:

 

8 июн 2021

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 26   
@manakamohammed2469
@manakamohammed2469 3 года назад
Love your work
@mdrayhanhossen5647
@mdrayhanhossen5647 3 года назад
Yes bro. You are great ♥️
@MasterCivilEngineering
@MasterCivilEngineering 3 года назад
Knowledge has a beginning but no end!
@RAMESHKUMAR-rs4en
@RAMESHKUMAR-rs4en 3 года назад
Great video bro...👌👌👌
@unknown_4024
@unknown_4024 2 года назад
Yo I’ve been in construction for 20 years never heard builder with that strong of an accent lol good video bro
@khan52310
@khan52310 3 года назад
steel of slab should be always under go beam steel ?
@DanielChristopher-js4fb
@DanielChristopher-js4fb 2 месяца назад
Hi Sammy nice video as usual thanks are the double mesh provided in distance of L by 4 ? to resist negative bending moment, or the entire floor
@PraveenPLCE
@PraveenPLCE 3 года назад
In what condition of loading or span....we go for double mesh ??
@UmeshSahu-di2ee
@UmeshSahu-di2ee 3 года назад
Next video plz From India🇮🇳🇮🇳🇮🇳
@awaz.663
@awaz.663 3 года назад
Walaikum Assalam Should we use single bars in residential buildings,?
@Thesis_SA
@Thesis_SA 2 года назад
I see single layer of mesh and reinf bars crossing through on either side of beam
@DanielChristopher-js4fb
@DanielChristopher-js4fb 2 месяца назад
Sammy pls,,could you do video on double mesh reinforcement commercial building
@herry1482
@herry1482 4 месяца назад
span between two main bar in bottom mesh ??
@axeltaud9202
@axeltaud9202 5 месяцев назад
what is the difference of mataiting slab and two way sab
@josephpinto8378
@josephpinto8378 3 месяца назад
What is the Slab Thickness.
@mohammedsamir3466
@mohammedsamir3466 3 года назад
👍
@kaifwriters2740
@kaifwriters2740 3 года назад
Walikumsalam
@hamadzahur7443
@hamadzahur7443 3 года назад
RCC water tank 10ft x 15ft Water 20000 ltr Zameen level say 12 ft hight 6 column bana raha Footing 4 ft beams columns footings May kon sa iron use karu aur kitny rods her beam, column, footing May lagau
@manny156able
@manny156able 2 года назад
Sir how to rectify if distribution bar placed on main bar on top mesh Please give some solution
@manny156able
@manny156able 2 года назад
Sir please give solution Concreting has been done in case of footing??
@kaifwriters2740
@kaifwriters2740 3 года назад
Bhai khriyet se ap ka number mil sakta h kya kuch baat karni h ap se.?
@KAMRANKHAN-xf7iq
@KAMRANKHAN-xf7iq 3 года назад
What's the need of double mesh??? Any reason??
@sadikali1986
@sadikali1986 2 года назад
Because of depth, single mesh and double mesh depends on the slab depth and load
@kgyanggangmei9609
@kgyanggangmei9609 4 месяца назад
Why using 12 mm not 10
@prappoahmed
@prappoahmed 3 года назад
Thanks Sir..
@machangmaipala6138
@machangmaipala6138 Год назад
Hindi main balu sir
Далее
Why we use double mesh at the supports
3:39
Просмотров 166 тыс.
Беда приходит внезапно 😂
00:25
Просмотров 326 тыс.
Two Way Slab Reinforcement
9:08
Просмотров 850 тыс.
Big Mistake in Cantilever Beam on Site
4:07
Просмотров 285 тыс.
Difference Between One Way Slab & Two Way Slab
3:19