EG4 6000 XP Full Install 

East Texas Homestead
Подписаться 17 тыс.
Просмотров 13 тыс.
50% 1

EG4 6000XP Off-Grid Inverter Installation Guide: Wiring, Settings, and Useful Tips
Use "ETHSave50Bucks" at checkout for a discount when shopping at Signature Solar.
Featured Products:
➡️ Torque Screwdriver Set: amzn.to/3OEwS0h
➡️ Ferrule Crimping Tool kit: amzn.to/49r0shQ
➡️ EG4 6000XP Off-Grid Inverter: signaturesolar.com/eg4-6000xp...
➡️ EG4 Chargeverter | 48v 100A Battery Charger: signaturesolar.com/eg4-charge...
➡️ EG4-LifePower4 Lithium Battery | 48V 100AH | Server Rack Battery signaturesolar.com/eg4-lifepo...
➡️ Check out all things solar at Signature Solar: signaturesolar.com/?ref=esttx...
In this video, I walk you through how I'm setting up my offgrid homestead by installing three EG4 6000XP inverters. These are by far the best off grid inverters i've worked with for those on a tight budget. I'll show you some of my wiring, which may not pass code where you live so be sure to do things the right way. I'll also emphasize important safety measures and the necessity of consulting local laws, ordinances, and product manuals. Tips and tricks for bypassing certain difficulties are shared, while viewers are advised to consider the potential need for equipment updates.
Remember, I'm not a professional and my actions should not dictate your approach.
I'll also detail the process for properly torquing connections and connecting battery cables and communication cables. A section on setting up inverters in parallel is covered using guidance from the product manual and additional advice.
00:00 Installing an off-grid system
00:24 Hanging the 6000EX Inverters
00:56 Safety Precautions and Manual Consultation
01:26 Installation of ENT Connectors
01:47 Wire Preparation and Connection
02:11 Use of Ferrules and Tool Kit
03:29 Wire Cutting and Connection Tips
07:05 Battery Cable Connection
10:39 Inverter Setup and Communication Cables
12:32 PV Line Connection and Isolators
14:08 Final Thoughts and Future Videos
Additional Notes:
Interested in homesteading and off-grid living? Subscribe for more!
Have questions or ideas for future videos? Drop them in the comments!
Remember, using the affiliate links above supports the channel and helps me bring more content like this to you. Thank you for watching, and I can't wait to share more of my homesteading journey with you. Catch you in the next one!

Опубликовано:

 

7 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 62   
@EastTexasHomestead
@EastTexasHomestead 5 месяцев назад
➡ Save on the 6000XP with code "ETXHOMESTEAD": signaturesolar.com/eg4-6000xp-off-grid-inverter-split-phase/?ref=esttxthst
@furiousfucshiagoddess7616
@furiousfucshiagoddess7616 12 дней назад
Thank you, but it seems this code is not valid!! Maybe it was for a limited time?
@Gamma662keV
@Gamma662keV 5 месяцев назад
You can't use aluminum wire for that grid connection. You can see on the bottom of the breakers that it says "Cu only". That connection is going to fail.
@iowac
@iowac 5 месяцев назад
Yes instructions say have isolator at the panels and of course with the 6000xp we have one right on panel. I might put it inside too
@diySolarPowerFunWithRay
@diySolarPowerFunWithRay 4 месяца назад
Very nice! I'm also installing one of these now. I just used your link to buy the torque driver.
@EastTexasHomestead
@EastTexasHomestead 4 месяца назад
Thanks! It’s a nice set :)
@Electronzap
@Electronzap 5 месяцев назад
Nice project!
@EastTexasHomestead
@EastTexasHomestead 5 месяцев назад
Thanks!
@theadventuresofarenaissancman
@theadventuresofarenaissancman 5 месяцев назад
I used a 2x4 to rest the inverter on when I installed my 1st inverter. 2nd inverter I used 2 screws to rest the inverter on. The 3rd install I used a smaller preinstalled screw for the top to hold the inverter while I installed the three other screws
@EastTexasHomestead
@EastTexasHomestead 5 месяцев назад
All of which were better than what I did. LOL
@theadventuresofarenaissancman
@theadventuresofarenaissancman 5 месяцев назад
@EastTexasHomestead I tried your method...I almost dropped the inverter. I had to move on to plan B
@EastTexasHomestead
@EastTexasHomestead 5 месяцев назад
Yeah... I almost lost it a time or two myself. Thought about using a jack or even drilling out keyholes as some do. Then i just decided to risk it and get it done.
@NestorTech000
@NestorTech000 5 месяцев назад
nice setup sir.from philippines solar installer
@EastTexasHomestead
@EastTexasHomestead 5 месяцев назад
Thanks and welcome
@sciglassblower
@sciglassblower 5 месяцев назад
Your communication cables are in the wrong ports. Check the diagram you showed. First inverter, right port cable goes into left port on 2nd inverter, same for 2nd to 3rd. On last inverter, right port cable goes into left on 1st inverter.
@daddio7249
@daddio7249 Месяц назад
I do hope you re-torqued the battery connection nuts, the actual torque is 97-106 inch lbs or 11-12 Nm
@markahdz
@markahdz 4 месяца назад
I just starting to learn about solar, this inverter looks like a great option for starting a small project, for what I noticed and read this unit can use power from the grid when running out of battery power or solar us not enough but cannot send back to the grid, quick question if you run out of battery will the inverter pull from the grid to keep everthing running and charge the batteries ? Thanks for the information.
@EastTexasHomestead
@EastTexasHomestead 4 месяца назад
That is correct! You can easily set the cut off percentage when it will stop using batteries and switch back to grid. Usually 15-20%. It will continue to supplement the grid with solar if you have it. You can then select a time to charge from the grid if you want to. I have it charge at night when I get free grid power. The downside, as you mentioned, is that I don’t have the option to sell back to the grid if I ever wanted to, with this unit. Hopefully that clears it up. Let me know if you have other questions
@markahdz
@markahdz 4 месяца назад
@@EastTexasHomestead sadly our local power monopoly will not pay enough lol, they just pay you the price they charge for generating power but they will charge usage-generating, I’m in south Texas and it looks like I may need to get a permit to install solar, not sure if will apply even if I install then on a porch. I can do the majority or maybe everything by myself but a license electrician is “required” I even thought on do a ground installation but knowing the guys in charge of the county they may even ask for a permit too. Again thank you for the information I hope I can get more information from my local authorities and see what is required for installation.
@bobcole3852
@bobcole3852 5 месяцев назад
Good job! Exactly what did you use to mount inverters?
@EastTexasHomestead
@EastTexasHomestead 5 месяцев назад
Thank you, sir! I talk about it here around the 7:5 minute mark ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-0OyEbkNgQdg.htmlsi=mIKVeGXZg0dK8ETT
@bhbaker220
@bhbaker220 Месяц назад
Is the cable you are using for ACin SOOW cable? If so, what gauge are you using, where did you get it from and what is the cost?
@EastTexasHomestead
@EastTexasHomestead Месяц назад
It is SOOW and 8 AWG. I think it was around $4/foot at Home Depot. However, it is not code compliant. For whatever reason, you can’t use this in a fixed location - but you can drag it all over your shop floor. 🤷🏼
@deanhobbs5388
@deanhobbs5388 3 месяца назад
@EastTexasHomestead is there a video where you show where /how you're splicing the line in (grid) into the 3 cables you're bringing into the 3 inverters? Thanks for making these videos ; it's been a huge help to me as I learn.
@EastTexasHomestead
@EastTexasHomestead 3 месяца назад
I think this video may be it. Let me know if not and I can try to clear it up. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE--daYzGhKutk.htmlsi=KFj8nQVKeboyVzi8
@jeffreydweeks
@jeffreydweeks 4 месяца назад
Do any of the Power companies in East Texas offer net metering or is it just a no. My wife and I are getting ready to move back and build on our property in East Texas and I cannot get an answer from the power company I talked too.
@EastTexasHomestead
@EastTexasHomestead 4 месяца назад
I don't know. I can tell you that we use Just Energy and have selected the free nights plan. It's pretty sweet to charge the batteries for free at night and use the energy during the day. If you're interested int that, I believe they are one of two that offer that type of plan. Feel free to use my link below which would give us both $75. Just an option. justenergy.com/refer/? referralCode=1444E81
@BluecollarRVliving
@BluecollarRVliving 5 месяцев назад
First of all, I would like to start off by saying thank you for all the knowledge that you put out there to everybody. I got my E4 6000 XP and December per other peoples recommendations 10,000 W of solar is recommended so that’s what I have. All of my parameters are correct and not exceeding the limits Every single time my unit gets close to 7000 W of PV input the unit starts screaming. Can you do a video bringing in that much Solar according to signature Solar this is a problem that they are starting to see and do not know what the problem is. They are sending me out a new unit , thank you for your help if you can
@EastTexasHomestead
@EastTexasHomestead 5 месяцев назад
Interesting. I only have 2000 W going into my system at the moment, so I can't replicate it yet. I have 15K of panels but nowhere to put them yet. I'll be sure to add this to my list of things to test moving forward. Thanks for the info, and sorry for your luck with that. Hopefully, the new inverter will work better and fix the issue. @martysurx111
@daddio7249
@daddio7249 Месяц назад
That "screaming" is just the fans ramping up. Turning 7000w of pv into power to charge your batteries creates a lot of heat. I have 11,000 watts of panels and two 6500EXs, in full sun they both start roaring until the batteries get charged. I just upgraded to two 6000XPs and will be starting them tomorrow.
@BluecollarRVliving
@BluecollarRVliving 19 дней назад
@@daddio7249 that’s not what it is because every time that happens the inverter shuts down the solar input and switches to grid while the inverter resets
@daddio7249
@daddio7249 19 дней назад
@@BluecollarRVliving I have 2 6000XPs running with zero problems. I have wired the grid pass through but have not closed the breakers, I have 11,040 watts of PV and have not needed it. Have you tried throwing the grid breaker and using just the PV power?
@BluecollarRVliving
@BluecollarRVliving 19 дней назад
@@daddio7249 I’ve tried everything you can imagine along with 4 hrs with tech support. If I keep my solar input at 6000 watts then it’s fine. Once the batteries are charged then I have no problem because my needs never exceeds 4500 watts
@brianhowe7667
@brianhowe7667 5 месяцев назад
I would say the hardest thing would be coming up with the $13,000 for inverters and batteries
@EastTexasHomestead
@EastTexasHomestead 5 месяцев назад
If you don’t have the cash it can be tough. We justified it by knowing it would pay for itself in a handful of years.
@danslamusique
@danslamusique 4 месяца назад
Just get one to start, this system is expandable. I just ordered one lifepo batt one xp and 10 400w panels to start out. I plan on getting another batt and panels later.. my cost for one of each was just over 4k
@Pepaw-Bill
@Pepaw-Bill 5 месяцев назад
I’m not a fan of Ferrell sleeves because it’s “another” mechanical connection. I tin (solder) multi strand cables. It’s stronger, less resistant and can take more heat.
@EastTexasHomestead
@EastTexasHomestead 5 месяцев назад
Thanks for sharing, Bill :)
@daddio7249
@daddio7249 Месяц назад
I would think just the opposite, metal expands when it gets hot making the connection tighter. Solder will melt when it gets too hot making the connection looser.
@steveanimatrix3887
@steveanimatrix3887 Месяц назад
as someone who worked in electronic repair for 30 years for a company, I'd just say don't tin cables that have heavy loads. I've seen many control boards with solder spattered all over the inside when a component fails and the power wires get very hot very quickly. Solder all over everything, which caused everything else to blow as well. This was common to see, not rare.
@URackADisciprine
@URackADisciprine 5 месяцев назад
I thought NEC requires DC conductors inside the house at least had to be encased in metal like an enclosure or liquid tight conduit?
@EastTexasHomestead
@EastTexasHomestead 5 месяцев назад
It probably does. This system will not be entirely up to code, but I will be doing everything safely.
@URackADisciprine
@URackADisciprine 5 месяцев назад
@@EastTexasHomestead The code tells you what to do for a reason...because that is what is ACTUALLY safe.
@EastTexasHomestead
@EastTexasHomestead 5 месяцев назад
Here's an example, the cable I used for my AC is "approved" to be drug all over a shop, have water and oil spilled on it, and be just fine. However, once I stop dragging it around the floor and fix it to the wall, which is arguably safer than stepping on it, the NEC says I'm in violation. This is perfectly safe; the conductors are audacity sized, it's out of reach and won't be snagging on anything, but it isn't "approved" for that location.
@URackADisciprine
@URackADisciprine 5 месяцев назад
@@EastTexasHomestead The NEC takes into account events and considerations you are not likely to ever think of. These events and considerations have been tested and/or experienced by laboratories, electrical engineers, master electricians and other professional organizations alike. But it's obvious the NEC doesn't apply to you. No point in arguing with a clueless RU-vidr thinking they are doing people a favor by posting a video of an illegal electrical installation. Could waste a lifetime doing that. Hope an inspection never comes your way...I really should hope for the opposite though, for your safety. If only common sense was common. Wish I could say it was a pleasure. Adios!!!!
@watchman1982
@watchman1982 3 месяца назад
⁠@@URackADisciprine Or the NEC just like other regulatory bodies like OSHA, EPA, etc…sole purpose is to think of new rules and regulations that overcomplicate things to justify their existence.
@sia3540
@sia3540 5 месяцев назад
Why can’t you charge from a 120 volt generator? Crazy 😜!
@EastTexasHomestead
@EastTexasHomestead 5 месяцев назад
I know! It feels like a ridiculous limitation. The chargeverter takes care of that issue though.
@iowac
@iowac 5 месяцев назад
You dag nabbid backwood backward country boy you cants be wires n black n reds backwoods i means backwards, same tang. Lol kidding. Thanks for links to those blue things where wires come in bottom of eg6000 i knew i was like i know something should go here. Great video, watching for what you say about the 120v generator. I not planning on using that at least to start but always good to learn bits i not aware of. Thanks for posting.
@EastTexasHomestead
@EastTexasHomestead 5 месяцев назад
HAHA! I know I'm not doing everything by the book but I really am trying to think through it and be safe. I'm glad the link helped. One of the problems I faced was not knowing what each part was called, so searching for it was all but impossible. I'm sure there's a better way to do a lot of this. Thanks for watching and leaving comments. :)
@iowac
@iowac 5 месяцев назад
@@EastTexasHomestead Main thing is you safe and as you said follow directions especially when it comes to the wiring portion so as to not cause a fire or get a shock of life. Looks good, I too no expert, but from others I am watching set their 6000xp up yours is right there. So are you letting your eg6000xp control the ground to neutral bond since you off grid? Set enabled? I had to do some reading and asking on that and from what I got was if off grid let the 6000xp enable ground neutral bond and in the breaker box you disable ground neutral bond as the 6000xp has it. Is that what you got also, might have missed if you mentioned it in video. LOL that was my issue I was like hmm I do not know what these are called and figured I would next time in Lowes or Home Depo check near the breaker panels for something that would be what goes in them, possibly ask but that can be hit or miss. PS God bless, great to see more followers of God and sharing the word and being the light to our savior Jesus.
@EastTexasHomestead
@EastTexasHomestead 5 месяцев назад
I'm actually grid-connected even though I run "off-grid" every day. So, I have the unit set so that the ground neutral bond is disabled, and the two are connected up at our meter pole.
@glendavis3639
@glendavis3639 4 месяца назад
What a disaster. As an electrical contractor, I must say that has got to be the sloppiest work I’ve seen in a while.
@EastTexasHomestead
@EastTexasHomestead 4 месяца назад
🫣
@turdferguson12
@turdferguson12 3 месяца назад
Does it work? Is it safe? That’s all that matters
@meilyn22
@meilyn22 2 месяца назад
Why don't you give specifics? You weren't trying to be helpful. You wanted to be rude.