Тёмный

ELCB/ RCCB working 

VINAY KUMAR
Подписаться 76 тыс.
Просмотров 383 тыс.
50% 1

In this video you can learn about ELCB/RCCB & their Application, Its working principle etc in Hindi as well as English.

Опубликовано:

 

8 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 247   
@zahidulislam2458
@zahidulislam2458 3 года назад
Very good information
@panditkuldeepvats907
@panditkuldeepvats907 4 года назад
Nice Explain sir ji
@jiteshbarot1098
@jiteshbarot1098 3 года назад
Nice video
@anandgupt6889
@anandgupt6889 4 года назад
Superb
@irenatonney8436
@irenatonney8436 3 года назад
wonderful
@anishrajput9847
@anishrajput9847 6 лет назад
Superb 👍👍👍.. thanks for the rccb ckt nd that mmf explanation...
@tarequrerahman768
@tarequrerahman768 3 года назад
thanks for your video
@ElectricalWale
@ElectricalWale 2 года назад
He is making nice video
@er.mahtabalam5349
@er.mahtabalam5349 5 лет назад
V.nice sir there was concept is very good..thanks sir
@PraveenKumar-yj8iv
@PraveenKumar-yj8iv 6 лет назад
verry nice knowlage sir. thanking verry much
@sakshichauhan2122
@sakshichauhan2122 4 года назад
Thank you thanks alot sir for this video it's too gud...
@omugalevillagechannel2538
@omugalevillagechannel2538 3 года назад
Hi
@bhojnarayanajay
@bhojnarayanajay 7 лет назад
aapka smjhane ka trika bahut achha aur clearly h...!!!👍👍👍
@butaelectrichome8465
@butaelectrichome8465 6 лет назад
Bhojnarayan Ajay d
@techadora2852
@techadora2852 4 года назад
Nice sir..👍
@missweety8744
@missweety8744 3 года назад
Nice
@ElectricalWale
@ElectricalWale 2 года назад
Nice
@muhammadsaeed3854
@muhammadsaeed3854 6 лет назад
Very informative video.......I like it very much.......love you ..way of you talking....... thanks from Pakistan
@ElectricalHindiTutorial
@ElectricalHindiTutorial 6 лет назад
Thank you Muhammad Saeed
@owaisbhat7845
@owaisbhat7845 6 лет назад
Helpful video. Thank you sir
@panditkuldeepvats907
@panditkuldeepvats907 4 года назад
Thank you
@sonukumarjatav8067
@sonukumarjatav8067 7 лет назад
thanks you sir aj se ap mere guru
@vinayakpatil6661
@vinayakpatil6661 5 лет назад
Thx alot sir, It was really nice explanation
@jamesonmatthew2654
@jamesonmatthew2654 3 года назад
you all probably dont give a shit but does anyone know a way to log back into an instagram account..? I stupidly lost the login password. I would love any tricks you can give me!
@noeeric9325
@noeeric9325 3 года назад
@Jameson Matthew instablaster =)
@jamesonmatthew2654
@jamesonmatthew2654 3 года назад
@Noe Eric I really appreciate your reply. I got to the site thru google and im waiting for the hacking stuff now. Seems to take quite some time so I will reply here later when my account password hopefully is recovered.
@jamesonmatthew2654
@jamesonmatthew2654 3 года назад
@Noe Eric It worked and I finally got access to my account again. I am so happy! Thanks so much, you really help me out !
@noeeric9325
@noeeric9325 3 года назад
@Jameson Matthew you are welcome :D
@bijayakumartunga3182
@bijayakumartunga3182 6 лет назад
Very nice
@srktechnical7009
@srktechnical7009 6 лет назад
Aapke samjhane ka tarika bohut acha hai
@nikhilyadav6794
@nikhilyadav6794 6 лет назад
Nicely explained 👌👌
@teslapowermind7335
@teslapowermind7335 6 лет назад
sir aur video bhi isi parkar banaye aap ek teacher se bhi jayada accha define kar rahe ho ek baar mai hi samajh aa gaya mind blowing sir
@ElectricalHindiTutorial
@ElectricalHindiTutorial 6 лет назад
Thank you
@RaviSingh-xo7my
@RaviSingh-xo7my 6 лет назад
an honest Tutor
@manishsolanki5849
@manishsolanki5849 5 лет назад
Aaj mere pass shock complain aya fault tha printing machine me shock lagta us machine ki body short hone se.. Magar is comp ki hi elcb thi mene testing me machine ka short testing liya magar aeh treep nai huva... 30 ma likha tha q nai huva hoga muje pata nai chala
@manishsolanki5849
@manishsolanki5849 5 лет назад
Ab koi customer ko Hume shefy divaice bolke ke laga de or aeh koi prefect work na Kare to kya karna chaiye... Company supply earthing bi power full tha.....
@bmeti9851
@bmeti9851 3 года назад
wow
@ElectricalWale
@ElectricalWale 2 года назад
Thank you brother
@mehuldholu1
@mehuldholu1 6 лет назад
Thank you for your information
@bhojnarayanajay
@bhojnarayanajay 7 лет назад
very gooooooooood concept....bhai
@ElectricalHindiTutorial
@ElectricalHindiTutorial 7 лет назад
+Bhojnarayan Ajay Thank you Ajay
@waheedahmed284
@waheedahmed284 6 лет назад
informative video thanks
@NISHANTSINGH1212
@NISHANTSINGH1212 6 лет назад
WellExplained
@symondish
@symondish 6 лет назад
Thanks for the excellent explanation.
@ElectricalHindiTutorial
@ElectricalHindiTutorial 6 лет назад
Thanks
@akashdhara3116
@akashdhara3116 5 лет назад
Excellent
@desivideshi4853
@desivideshi4853 6 лет назад
Very good definition.
@khadarmd8116
@khadarmd8116 7 лет назад
thank u sir very good information
@satishkumargupta759
@satishkumargupta759 6 лет назад
Very nice sir
@Aadi-ks4wp
@Aadi-ks4wp 6 лет назад
Very nice sir
@rajneshyadav3225
@rajneshyadav3225 6 лет назад
very nice video guru g
@panditkuldeepvats907
@panditkuldeepvats907 4 года назад
👍👍👍
@shaifali1130
@shaifali1130 4 года назад
बहोत सुक्रिय
@vijendrakaithal4049
@vijendrakaithal4049 6 лет назад
very nice elaboration sir
@AnujKumar-hy4cn
@AnujKumar-hy4cn 6 лет назад
good bhai gee
@akashpawar4247
@akashpawar4247 5 лет назад
Sir working samaj aya, PR aapne connection nahi bataya.
@avtarsolkh4228
@avtarsolkh4228 7 лет назад
good job sir bahut achha difine kiya aapne 👍👏👏
@ElectricalHindiTutorial
@ElectricalHindiTutorial 7 лет назад
+Avtar solkh Thank you avatar
@d.cvlogs345
@d.cvlogs345 4 года назад
Thanks 😊 sir
@lockamit
@lockamit 6 лет назад
SUPER ,👍🏼
@narsinghkumar9054
@narsinghkumar9054 7 лет назад
Nice concept bhaiya
@ElectricalHindiTutorial
@ElectricalHindiTutorial 7 лет назад
+narsingh kumar Thank you Narsing
@govindbansode90
@govindbansode90 5 лет назад
Nice working
@jatinchatterjee2219
@jatinchatterjee2219 6 лет назад
Bhai rccb ke andar c.t. hoti hai aur jb residual current flow hota hai to c.t. usko sense kr leta hai aur c.t. ke secondary se ek electromagnet connect rehta hai jo residual current flow hone se wo as a magnet behave krne lagta hai aur wo rccb ke moving contact ko instantly apni taraf attract kr leta hai jisse moving contact fixed contact se alag ho jata hai aur ckt open ho jata hai or rccb trip ho jati hai
@vikaspandey3678
@vikaspandey3678 5 лет назад
Jatin Chatterjee
@jatinchatterjee2219
@jatinchatterjee2219 5 лет назад
VIKAS KUMAR PANDEY kya hua pandey ji kuch galti ho gayi kya
@manishjha7550
@manishjha7550 5 лет назад
Good
@rckengineers9917
@rckengineers9917 7 лет назад
Very Important Information
@ElectricalHindiTutorial
@ElectricalHindiTutorial 7 лет назад
+RCK Engineers Thank you for your feedback
@farminginindia980
@farminginindia980 6 лет назад
Pls explain typs of panels
@jumarahim382
@jumarahim382 6 лет назад
Super sir
@lalitdas3883
@lalitdas3883 7 лет назад
viry nice vidoe sir
@stephenfernandes9208
@stephenfernandes9208 6 лет назад
Thank-you so much
@arupghoshal5814
@arupghoshal5814 3 года назад
I Went to check for UPS back up for our scanning electron microscope machine . That's why i was switched off the ups switch and connect multi meter at battery . At same time our elcb tripped, and machine off. And a burning smell came out from elcb. After that when I tried to elcb on with main power on. Elcb tripped automatically again and again . Can you please described the reasons behind that???
@deepak-ke7xo
@deepak-ke7xo 7 лет назад
nice explanation
@ElectricalHindiTutorial
@ElectricalHindiTutorial 7 лет назад
Than you deepak
@sasimoolepuram
@sasimoolepuram 6 лет назад
Ghar ke liye RCCB konsa specification ka hona chahiye? Total watt 5000 ke niche. Single phase.
@Shera_wrestlers
@Shera_wrestlers 6 лет назад
good sir
@rajeevkumar-wi7di
@rajeevkumar-wi7di 5 лет назад
what is better for domestic use elcb or rccb ? My home load is 10 KW.
@ElectricalHindiTutorial
@ElectricalHindiTutorial 5 лет назад
Rccb
@jitendrasah2668
@jitendrasah2668 5 лет назад
Sir , current operated ELCB or RCCB both are same or different
@ElectricalHindiTutorial
@ElectricalHindiTutorial 5 лет назад
RCCB is better than ELCB Both are use for same purpose but working principle is difference
@ashokkumargochhayat8603
@ashokkumargochhayat8603 5 лет назад
Thanks
@amrishkumarsaini8635
@amrishkumarsaini8635 6 лет назад
great
@dineshkatuwal4223
@dineshkatuwal4223 6 лет назад
Earth line if not provided at distribution board, is it possible to auto trip when default of current or when touch of human body.
@ElectricalHindiTutorial
@ElectricalHindiTutorial 6 лет назад
In case of RCCB it is possible but in case of Elcb it is not possible......
@anandsanglikar1884
@anandsanglikar1884 6 лет назад
Sir, very Nice clip I have connected ELCB L & T at Mains but I have also installed Solar power supply through Inverter which also charges 2 batteries so I want to confirm that Whether ELCB will also work in the system ???
@pandurangjangale7288
@pandurangjangale7288 6 лет назад
inverter supply connect to main switch or MCB output . before ELCB
@pandurangjangale7288
@pandurangjangale7288 6 лет назад
inverter power supply must connect to main switch or MCB output & before (in between) ELCB then it will be work properly
@anandsanglikar1884
@anandsanglikar1884 6 лет назад
Pandurang Jangale Thank you very much
@electricalmohitsharma6448
@electricalmohitsharma6448 4 года назад
Sir mcb ki place pe elcb bhi lga skte hai Kya plz btaye
@ElectricalHindiTutorial
@ElectricalHindiTutorial 4 года назад
You can install only one ELCB/RCCB for your home while individual MCBs are required for all room
@nehulnehulkayasth8250
@nehulnehulkayasth8250 6 лет назад
supper video sir
@ManpreetSingh-sf7xg
@ManpreetSingh-sf7xg 6 лет назад
Thanks you.
@koklithakur
@koklithakur 7 лет назад
nice video sir
@ElectricalHindiTutorial
@ElectricalHindiTutorial 7 лет назад
Thank you NIHAL SINGH
@vasimmujawar3810
@vasimmujawar3810 5 лет назад
Elcb baithane ke liye ghar ko earthing jaruri hai kya??????
@ElectricalWale
@ElectricalWale 2 года назад
Yes but agar ap aise bhi lagana chahe to laga sakte aisa nahi he ki Earthing ke bagain nahi kam krta he kam krega aisa bhi laga sakte ho
@dushyantsharma4148
@dushyantsharma4148 7 лет назад
Thanks sir
@vipinup53entertainment17
@vipinup53entertainment17 7 лет назад
👌👍
@dineshkapse8125
@dineshkapse8125 7 лет назад
👍👌
@AnandYadav-ur2ro
@AnandYadav-ur2ro 6 лет назад
video achchha hai
@vikasmishra38
@vikasmishra38 5 лет назад
Sir bataye ki meter k in put me single pole ki jagah two pole se Supply de sakate hai kya
@KPishere
@KPishere 6 лет назад
So if the current is leaky inside the panel, why didnt ELCB operates and shuts the suuply instead of waiting for someone to get a shock and then work
@ElectricalHindiTutorial
@ElectricalHindiTutorial 6 лет назад
Dear khawar this is not possible because RCCB is made for detect leakage current. May be your Your panel earthing is not proper in case of ELCB. or may be leakage current rating of your ELCB /RCCB is more.....
@priyankugoswami4442
@priyankugoswami4442 5 лет назад
@@ElectricalHindiTutorial sir voltage elcb sayad trip hoga uss case main...coz agar live metal body ko touch jb karega toh uska voltage toh earth ke voltage se differ karega na?
@anandagr03
@anandagr03 6 лет назад
shall we use both MCB and RCCB for better result if yes what should be the order of connection.
@ElectricalHindiTutorial
@ElectricalHindiTutorial 6 лет назад
Yes u can go for it . Main supply connect to MCB and then connect ELCB/RCCB
@muhammadsaeed3854
@muhammadsaeed3854 6 лет назад
Ok I got it sir.....phir sir for the safety at home kitnay miliampere ka elcb breaker lgaye 63amp
@ElectricalHindiTutorial
@ElectricalHindiTutorial 6 лет назад
You can use 30 mA or 100 mA
@neelkanth4670
@neelkanth4670 5 лет назад
Sir kya difference hai ki hum i/o kisi side bhi lga de to? Means ki agar hum input ki jagah output lga de to kya hoga sir difference isme ?
@sasimoolepuram
@sasimoolepuram 6 лет назад
Ghar ke liye RCCB konsa specification ka hona chahiye? Total watt 5000 ke niche. Single phase. DP or FP?
@ElectricalHindiTutorial
@ElectricalHindiTutorial 6 лет назад
If total load is 5 kw then you have required Single phase supply so you have required DP(double pole) RCCB. Generally when load is exceeding from 7.5 kw then we required 3 phase supply so in three phase supply you have required 4 pole RCCB. but here load is less than 5 kw then you required only DP RCCB. Let load is 5kw then you required 40 Amp. 100mA RCCB, Double Pole
@sasimoolepuram
@sasimoolepuram 6 лет назад
Thank you so much for your valuable advice.
@user-gx8fb3dn2f
@user-gx8fb3dn2f 7 лет назад
gud job
@ElectricalHindiTutorial
@ElectricalHindiTutorial 7 лет назад
+Heera Singh Thank you
@ashanair1976
@ashanair1976 5 лет назад
Short circuit mai konsi RCCB phele trip hogi zada ampere wali ya kam ampere wali?
@ElectricalHindiTutorial
@ElectricalHindiTutorial 5 лет назад
Jiska amp rating km hoga.
@deepakrane1047
@deepakrane1047 6 лет назад
ele water gizar ko elcd laga sakte hi
@mirzaataullahbaig413
@mirzaataullahbaig413 6 лет назад
what in case of three phase 4 pole RCCB
@prakashpanikar
@prakashpanikar 6 лет назад
How will test house wiring using of Megger pls upload
@yaseenali5341
@yaseenali5341 7 лет назад
slam sir elcb ya rccb single phase 220 se over volte hu jae 300 tk light wgra over volte se khrab hu jae is fult mai elcb ya rccb trip kre ga for example over volte mai kam kre ga?
@ElectricalHindiTutorial
@ElectricalHindiTutorial 7 лет назад
+Yaseen Ali Yaseen generally elcb /rccb not designed for short circuit or over load. Bt now a days mostly companies like Hevells, Siemens, Mitsubishi etc provide short circuit & over load protection in ELCB /RCCB.
@lalitrajak5401
@lalitrajak5401 6 лет назад
Sir house aur industrial wiring main kitane miliampear ka rccb lagana chahiye aur kya hisab se laganachahiye sir bataye
@vipulbharvad3619
@vipulbharvad3619 6 лет назад
63ampr
@mohdajeej3397
@mohdajeej3397 7 лет назад
Good
@kishorlchaudhari2244
@kishorlchaudhari2244 6 лет назад
Voltage between neutral and earth, in early morning is 10 to 18 volts, in afternoon 8 to 10 volts, in evening 10 to 15 volts. In early morning if I start /run, 2kw water heater or 1HP bore jet pump or both, RCCB(32A/30ma, Havells) of my house trips. If I run both load in afternoon or at night, RCCB donot trip. What is the problem.
@ElectricalHindiTutorial
@ElectricalHindiTutorial 6 лет назад
Either main transformer neutral earthing is weak or there is unbalance load at RYB. There may be heavy leakage in any phase somewhere. Due to low voltage between neutral and phase in the morning RCCB trips at high initial inrush current however In the after noon it little better.
@editorsirji4506
@editorsirji4506 6 лет назад
sir ye batayeye ki erthing ka use na karke ek normal home laod ke liye RCCB ka use kar saktein hai to kis tarah RCCB ka use karein
@e.welectricalsolarservices3664
Sir mene yek jagah pe 30m amp ka rccb lagaya but vo trip ho raha hai....or nikal liya to line chal rahi hai....so kya problem ho sakta hai........ earthing bhi nikal ke test kiya
@ElectricalHindiTutorial
@ElectricalHindiTutorial 6 лет назад
RCCB isliye trip Hua bocoz waha leakage current 30mAmp. Se jayada h. Ho skta h ki wire ka insulation khi weak ho gaya ho ya fir ho skta h ki aapke yaha koi aisa device ho jiska leakage current 30 mAmp se jayada ho.
@e.welectricalsolarservices3664
Thank you sir....but iska solution kya hai ...wiring to nahi badal sakte ab..
@ElectricalHindiTutorial
@ElectricalHindiTutorial 6 лет назад
So firstly check step by step that where is current leakage......
@e.welectricalsolarservices3664
Ok sir thank you so much...
@ArjunKumar-bj9bm
@ArjunKumar-bj9bm 6 лет назад
fantastic video par mera ek sabal h ki agar ham ne pure ghar ke switch board ko earth kiya h to hame rccb lgani jajuri hoti h ya nhi plz reply
@ElectricalHindiTutorial
@ElectricalHindiTutorial 6 лет назад
Bilkul jaruri h
@yuvihurts1639
@yuvihurts1639 7 лет назад
wow thank you so much
@ElectricalHindiTutorial
@ElectricalHindiTutorial 7 лет назад
+Pravesh Kumar welcome
@yuvihurts1639
@yuvihurts1639 7 лет назад
siR pLeaSe mAkE a viDeo abOut sWitCh gEar just LikE pAnEL bOaRd ciRcuiT brEakErs fEEders and trAnSfoRmEr pLeAse
@ElectricalHindiTutorial
@ElectricalHindiTutorial 7 лет назад
+Pravesh Kumar I will upload shortly
@yuvihurts1639
@yuvihurts1639 7 лет назад
thank you so much
@aniljaiswaraniljaiswar8146
@aniljaiswaraniljaiswar8146 6 лет назад
Anil.kimar
@ArshadKhan-tf1pb
@ArshadKhan-tf1pb 6 лет назад
Sir Rccb ka ager out put phase and neutral short ho to trif nahi kerti.os ke ley konsa breaker use hoga
@priyankugoswami4442
@priyankugoswami4442 5 лет назад
uske liye toh fuse hain hi naa main meter ke aage connected..wo urr jayega
@manuverma753
@manuverma753 7 лет назад
Sir, kya over light ati hai kya mcb trip karegi ki nahi
@SuperNirajkumar
@SuperNirajkumar 7 лет назад
kya two phase me elcb laga sakte hai
@singleboy6766
@singleboy6766 5 лет назад
Sir agar elcb ke bad MCB lagaye to kya elcb drip karegi
@mohammadakhtar5738
@mohammadakhtar5738 7 лет назад
bery nice sir and sir meri aapse ek requist hai aap acb or vcb ke uper bhi video banao ke wo kiya hota hai use kahan karte hain uska working principle kiya hota hai
@SS-xj8or
@SS-xj8or 6 лет назад
Good video Sir ek question hai aapse Mere ghar pe aksar high voltage ki problem aati rahti hai jis se mere ghar ke sare pankhe bulb aadi jal jaya karte hai Sir kya koi aisi bhi device aati hai jo ghar k main light wale supply par laga diya jaye jisse jaise hi high voltage ho to vo device ghar k saare light automatically kat de jis se ghar ke sare electric saman safe bache rahe Sir plz plz plz reply
@ElectricalHindiTutorial
@ElectricalHindiTutorial 6 лет назад
Agar voltage fluctuations ki problem h to aap automatic voltage stabilizer laga skte ho jo ki ghr ki voltage ko hmesa maintain rakhega. Aur ye problem nhi aayegi.
@SS-xj8or
@SS-xj8or 6 лет назад
Sir ji mere ghar pe already stabilizer laga hua hai Abhi kuchh din pahle hi tar face to face ho gaya tha jisse stabilizer bhi jal gaya Koi aisi device bataiye jo ki high voltage hone par poore ghar ki light hi kat de
@ElectricalHindiTutorial
@ElectricalHindiTutorial 6 лет назад
Waise to stabilizer me over voltage protection lga hota h bt agar phir v aisi problem h to aap market se over voltage cutoff relay purchase kr stabilizer se phle lga skte ho jo ki over voltage hone pr supply ko cut kr dega
@shivchanderkumarroyyadav9613
@shivchanderkumarroyyadav9613 6 лет назад
Electrician Shivchander Kumar Ray yadav Hali bazar banbira Samastipur
@hay12345j
@hay12345j 6 лет назад
sir mere pass water heater he or usame kabhi sort sarkit current na aaye to muje elcb lagani chahiye kabhi current lagta he to elcb bund ho jati he yes or no
@pranavutekar241
@pranavutekar241 4 года назад
Bhai ye banda sirf bata raha hai usko bhi nahi pata .
@mdshahid2a842
@mdshahid2a842 6 лет назад
Please sir tell me fast RCBO kiya hai kisliye use kiya jata hai
@ElectricalHindiTutorial
@ElectricalHindiTutorial 6 лет назад
RCBO stands for residual current circuit breaker with overload protection. Its mean it is combination of (RCCB + MCB). In RCBO additional over load feature is also available
@palashbiswas4163
@palashbiswas4163 6 лет назад
100ma elcb zatkha lagnese bandh hoga kya
@mdsshekh3563
@mdsshekh3563 5 лет назад
cone yarn Dyeing ke panal par video bnaye sir
@k.ssingh7064
@k.ssingh7064 6 лет назад
thanx sir 40 k.w. load ke liye kis rating ka rccb use kare
@ElectricalHindiTutorial
@ElectricalHindiTutorial 6 лет назад
You have required 125 amp, 30mAmp(leakage current) rccb required for 40 kw load(in 3 phase supply). You can also purchase 125Amp,100mAmp. Rccb.
@sakshichauhan2122
@sakshichauhan2122 4 года назад
Sir ek confusion hai ye jo aapne RCCB ki working batai hai kya wahi working ELCB ki v hogi
@ElectricalHindiTutorial
@ElectricalHindiTutorial 4 года назад
Working of elcb & rccb approx same but here is one main difference between elcb &rccb is that earthing is mandatory in case of elcb, without earth elcb will not work while in case of rccb earth is not required.
@sakshichauhan2122
@sakshichauhan2122 4 года назад
@@ElectricalHindiTutorial tanx sir
Далее
Mark Rober vs Dude Perfect- Ultimate Robot Battle
19:00
All About UPS, Double conversion UPS
20:23
Просмотров 13 тыс.
MCB and RCCB circuit breaker difference, in Hindi
8:13
What are the ACB Setting.
21:03
Просмотров 182 тыс.
How Does ACB (Air Circuit Breaker) Work?
11:27
Просмотров 26 тыс.