Electric Cables - Basic, Reinforced and Double Insulation 

eFIXX
Подписаться 719 тыс.
Просмотров 25 тыс.
50% 1

Joe Hammond takes a closer look at the importance of cable insulation, and how it plays an essential role in providing basic as well as fault protection. Electricians everywhere have undoubtedly witnessed unprotected conductors outside their elements - but with this knowledge on hand, they can now ensure that cables are kept safe from external forces!
This question was raised following our review of the Wago Gelbox which provides IPX8 protection for Wago 221 connectors.
Watch the full review here 👉 • How to Make Your WAGO ...

Опубликовано:

 

26 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 45   
@efixx
@efixx Год назад
This question was raised following our review of the Wago Gelbox, which provides IPX8 protection for Wago 221 connectors. Watch the full review here 👉 ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-1iyVHIAoQMI.html
@morganjames9345
@morganjames9345 Год назад
Joe is a great guy , he attended my testing and inspecting course to help out , wouldn’t lie about climbing a mountain near him though 🤣👍🏻
@efixx
@efixx Год назад
Ooooookay? Sounds like there's an interesting back story there...
@morganjames9345
@morganjames9345 Год назад
@@efixx Ask Joe about it lads, top bloke he is 👊🏻
@mrbugenhagen3364
@mrbugenhagen3364 Год назад
Nice video and it is great to see that the team is growing bigger. But i have to say that the sun scares me more than water ever have. I have seen some old sketchy cables where the insulation falls of to the bare copper just by touch.
@dennisphoenix1
@dennisphoenix1 Год назад
Anyone who is asking why it's non compliant isn't a competent person.
@darylsavage119
@darylsavage119 Год назад
Totally agree with this. Sadly the amount of gold card holders I have to argue this point with is scary
@tomtamarillo6349
@tomtamarillo6349 Год назад
Your contect is soooo good. Always enjoy watching your stuff. Keep on going
@efixx
@efixx Год назад
Thanks Tom, we will! 👍
@johnwaby4321
@johnwaby4321 Год назад
As for the meter tails there is plenty for marking tape and cable tys with marking on to enable the grey outer sheath to enter the enclosure.
@LC-rj6ok
@LC-rj6ok 4 месяца назад
Hi there, I have just had an EICR done on two flats. The cables running from the meter box outside are double insulated and there is a cut out fuse between the meter and the cables running to the flats. Before the meter is the 100amp supply cut out fuse. The electrician has failed this and says I need to change the isolator switches to fused isolator switches and that I need mechanical protection on the cable that is just over 3m in length. The electrics were done in the early 1990's when the flats were built. I have had another electrician tell me this is not needed.
@ACDC271
@ACDC271 Год назад
Who is this cheerful, portly gentleman?
@efixx
@efixx Год назад
This is the latest Joe to join our ranks, he's good isn't he? 😃
@ACDC271
@ACDC271 Год назад
@@efixx Listening to his voice is like waves of smooth caramel gently lapping over my body : )
@boriss.861
@boriss.861 Год назад
Minor quibble: Elves and Pixies you referred to section 412.1.1 as "dot 1 dot 1. I'm sure you would not refer to 1.5 as being 1 dot 5. or Period. It's 412 subsection 1, sub-sub section 1 or 412 point 1 point 1.
@efixx
@efixx Год назад
This is an interesting discussion point (or dot) actually, a couple of the IET chaps use the dot format, having said that I quite like sub-sub-section! 😃👍
@AutoCADRevitByju
@AutoCADRevitByju Год назад
Good information
@kevy427
@kevy427 Год назад
I can't understand why some Sparks strip the supplementary insulation off of meter tails in the consumer unit before it goes into the main switch? This should be left intact all the way to the main switch. Should the basic insulation be damaged and someone comes into contact with it then they're toast as there's not much upstream to protect them other than a 100A fuse. I've even seen blue and brown flex-tails with the supplementary insulation stripped off. Beggars belief
@PardoeElectrical
@PardoeElectrical Год назад
I agree, when installing grey meter tails, just use brown and blue insulation tape to identify your conductors 🤷🏼‍♂️
@r3co0
@r3co0 Год назад
Folk do it to identify colours when they cant be arsed taping them
@IAmThe_RA
@IAmThe_RA Год назад
Or just use heat shrinkable sleeves.
@sergiofernandez3725
@sergiofernandez3725 Год назад
If in doubt, then double insulate it. Reminds me of 15 - 20 years ago. If in doubt then bond it.
@efixx
@efixx Год назад
😂 People still feel that way about bonding Sergio. 😳
@seprishere
@seprishere Год назад
You have TWO Joes?
@efixx
@efixx Год назад
Three actually...
@Dog-whisperer7494
@Dog-whisperer7494 Год назад
It’s basic common sense that the gell box on its own doesn’t comply. Oh and welcome to the eFIXX team hopefully you will last longer than that James bloke one video wonder 😂 good video for your first time
@efixx
@efixx Год назад
We answer the questions people ask! And James is working on new content. 👍
@Dog-whisperer7494
@Dog-whisperer7494 Год назад
@@efixx I wasn’t having a pop. Guy’s. Just pointing out what he already said , like some other person said if you have to ask why it’s not compliant your not a competent spark . As for James I was being sarcastic . But to-be fair he has only done one video for eFIXX so far . Also I like James he certainly knows a thing or two.
@saqibnawab7532
@saqibnawab7532 Год назад
Basic insulation exposed and accessible to touch-C2 Basic insulation exposes but out of reach and not accessible to touch C3.
@bramcoteelectrical1088
@bramcoteelectrical1088 Год назад
If anyones a sparky and asking this basic question thats a bit scary.😮
@dirkcdejong
@dirkcdejong Год назад
Right at the start of the chapter 4 of the standard it says you can choose one of the protective measures. When you choose automatic disconnection you don’t need double isolation. Or do you? Then the enclosure seems unnecessary..
@DS-tp6vx
@DS-tp6vx Год назад
ADS involved an earthed metallic enclosure. Still enclosed either way.
@AndrewLumsden
@AndrewLumsden Год назад
So would wrapping the individual conductors up to, and including, the gel box with self-amalgamating tape bring it up to code?
@dennisphoenix1
@dennisphoenix1 Год назад
No , tape isn't a recognised insulation
@zeljomirtanackovic1529
@zeljomirtanackovic1529 Год назад
Some of the gear there is absolutely nonsensical, you got box which is if I am not mistaken ipx6 and by adding electrical gel it than becomes ipx8 so why would anyone use box within the box???
@stephenllewekyn706
@stephenllewekyn706 Год назад
TTFM? Who is this gentleman what happened to the last bloke?
@efixx
@efixx Год назад
He's the latest Joe on the team! 😃 TTFN.
@AndrewLumsden
@AndrewLumsden Год назад
TTFN not M 🙄🙄🙄 Who are you?
@SamButlerUK
@SamButlerUK Год назад
@@AndrewLumsden ta-ta for Mao 🇨🇳
@jameshansing5396
@jameshansing5396 Год назад
@@AndrewLumsden who are YOU? 😂
@SpNick3
@SpNick3 Год назад
What’s the point then, why not use a wiska box and fill it with gel?
@efixx
@efixx Год назад
Because this way, you don't have to fill it up with gel...
@jameshansing5396
@jameshansing5396 Год назад
Gel is expeeennnyyyyy
@jameshansing5396
@jameshansing5396 Год назад
People actually didn’t know this? 🥺😳 Provably out doing EICRs right now from their approved contractor signed vans! 😞
Далее
Uncovering the Mystery of Glare - What is UGR19?
4:58
Просмотров 4,8 тыс.
Why Knowing WIRE INSULATION Types Is Crucial
10:16
Просмотров 207 тыс.
Это ваши Патрики ?
00:33
Просмотров 33 тыс.
🎙ПЕСНИ ВЖИВУЮ от КВАШЕНОЙ
3:05:21
Я ИДЕАЛЬНО ПОЮ
00:31
Просмотров 476 тыс.
Don't Get Burned by MC4 Solar Connectors
13:41
Просмотров 66 тыс.
The most deadly project on the Internet
15:14
Просмотров 7 млн
Thermoelectric cooling: it's not great.
32:51
Просмотров 1,9 млн
How 3 Phase Power works: why 3 phases?
14:41
Просмотров 1,1 млн