Electro-Plumbing Repair… of my home heat zones that won’t heat although the boiler is running fine!! 

ElectroBOOM
Подписаться 8 млн
Просмотров 1,6 млн
50% 1

What?! The title wasn't descriptive enough for you?! Then just watch the video! OR get my new MERCH: electroboom.cr...
Thanks for your support @ / electroboom
Post your submissions to: / electroboom
My Facebook: / electroboom
My Twitter: / electroboomguy
My other articles: www.electroboo...
Thanks to CircuitSpeciali... and keysight.com for proving my essential lab tools and giveaways.
Checkout my Amazon picks (my affiliate link): www.amazon.com...
Below are my Super Patrons with support to the extreme!
Nicholas Moller at www.usbmemoryd...
Sam Lutfi
Peter Membrey
J4yC33
My sponsors and top patrons: www.electroboom...
Enter your school for tools: goo.gl/forms/V...
By: Mehdi Sadaghdar

Опубликовано:

 

23 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 3,2 тыс.   
@arcadeuk
@arcadeuk 2 года назад
I like how the plumber decided that the valves must be as close to the wall as possible, so that you need a special screwdriver to open them, instead of anywhere the the 3-4 foot of space between the valves and the boiler
@Jmoneysmoothboy
@Jmoneysmoothboy 2 года назад
It might have been two separate crews doing the work like the plumber who ran the pex around the house and then the HVAC boys installed the heater and valves and stuff and things.
@guyh3403
@guyh3403 2 года назад
Nice to see you here sir ;)
@AlexRutiaga
@AlexRutiaga 2 года назад
so they require their services again, if you dont have a special tool youre screwed
@TheGazzap45
@TheGazzap45 2 года назад
To be fair, all the plumbing is a shit show! So messy!
@misstakenot9582
@misstakenot9582 2 года назад
@@TheGazzap45 The wiring certainly is. OK, it's only 24V, but it's still crap.
@theironworks6797
@theironworks6797 2 года назад
Telling an electrical engineer they can't do something is like questioning a wizard's power.
@inurokuwarz
@inurokuwarz 2 года назад
The moment he realized the motor had been "fixed" by short circuting was exactly the same as a wizard opening a book of dark magic.
@evail7392
@evail7392 2 года назад
They either succeed or kill themselves trying to prove everyone wrong?
@Spooglecraft
@Spooglecraft 2 года назад
@@inurokuwarz i remember a trick to fix those christmas lights if one bulb is burnt out and you don't wanna try to track it down: hook it up to a taser or other high-voltage source and zap it. this burns and welds the broken filament or something in the broken bulb, so the circuit is closed again. of course, this is very hacky
@puriap250
@puriap250 2 года назад
@@inurokuwarz "And they say dark magic is bad"
@tvishmaychoudhary69
@tvishmaychoudhary69 2 года назад
@@Spooglecraft and he even discovered it on -accident- Research
@Haph3us
@Haph3us 2 года назад
As someone that does commercial HVAC controls for a living, it was interesting seeing you work through this problem.
@Coltrain207
@Coltrain207 Год назад
Same here, it’s cool seeing how someone this smart troubleshoots something I’m very familiar with
@Fishifyed
@Fishifyed 7 месяцев назад
HVAC, more like highway robbery!
@wotizit
@wotizit 2 месяца назад
Hectic stuff
@TheSatchrox
@TheSatchrox 2 года назад
As someone who has worked on everything from dehumidifiers to industrial boilers and refrigeration, I can say he missed his calling. Fantastic job again by Electroboom.
@maxweber06
@maxweber06 2 года назад
7:48 Amazing, resoldering a disconnect by running high voltage through the circuit!
@mrtango1824
@mrtango1824 2 года назад
Most likely not, far more likely dust causing a short circuit which at LV remained, but HV burnt it away.
@mernok2001
@mernok2001 2 года назад
@@mrtango1824 Dust isnt conductive enough to cause a short circuit at low voltage.
@Xalendare15
@Xalendare15 2 года назад
Arc welding!
@mernok2001
@mernok2001 2 года назад
@@Godspamit Could have also been a loose or oxidized connection that was open cicuit at 30V,but became shorted at 120V and the connection welded from the high current.
@JayzTwoCentzIG
@JayzTwoCentzIG 2 года назад
I'm guessing metal shavings from the constant operation
@werdwerdus
@werdwerdus 2 года назад
the short circuit path is probably there in case all of the valves close, so you don't get a huge pressure spike and the water can continue to flow
@merlijniboy
@merlijniboy 2 года назад
Or it could be one of the safety features when you ask for a low flow rate (valves almost closed). I think these type of units need at least some flow, else they could get dangerous
@alanpatterson2384
@alanpatterson2384 2 года назад
Yes, but it should be a restricted flow.
@kimsballs
@kimsballs 2 года назад
you have been promoted above Doctors.
@adinackerman5481
@adinackerman5481 2 года назад
So it's a flyback diode.
@christiancruvinelfranca2260
@christiancruvinelfranca2260 2 года назад
We have this bypass in chiller water cooled systems. It exists so the evaporator has a constant water flow even if there is no demand in the line.
@viditsinha7865
@viditsinha7865 2 года назад
My father and grandfather are electrical engineers and I can relate to the hierarchy, literally every problem is fixed by them
@zierlyn
@zierlyn Год назад
@dejuren Yes. But it might hurt.
@JolzFarm
@JolzFarm Год назад
​@@dejuren1367you'd be shocked
@yoitsrob
@yoitsrob 2 года назад
HVAC tech working on EE degree here, love the videos. This one brought me back to early days of my apprenticeship where I had to figure out the same issues. Having the nest controller makes things so much nicer
@kerimgueney
@kerimgueney Год назад
That sounds like such a cool career/educational path. How old are you, if I may ask?
@zierlyn
@zierlyn Год назад
@@kerimgueney Since you haven't gotten a reply, here's the way I got into HVAC which is one of many possible paths. I was an electrical apprentice for a while, then got a job with an HVAC controls company installing control equipment. I've known plumbers that got into HVAC the same way. From there, experience and interest can move you into the refrigeration side or the controls side. I went the controls route, but it would have been just as easy to go in any direction, and most trades companies will cooperate with schools to complete your training at the same time. Basically start at the bottom and work your way up, following your interests.
@kerimgueney
@kerimgueney Год назад
@@zierlyn thank you. I appreciate the detailed response.
@Yupppi
@Yupppi 2 года назад
"Higher voltage is potentially more dangerous" this is the highly scientific and educational content that I've watched years of electroboom for. I wish they taught wisdom like this in schools.
@Jmoneysmoothboy
@Jmoneysmoothboy 2 года назад
They haven't found a way yet considering how many dudes turn into mist on a yearly basis wrangling the damn stuff.
@U014B
@U014B 2 года назад
Hehe, _potential_ ly.
@wlockuz4467
@wlockuz4467 2 года назад
I love how plumbing jumped to rocket science instantly 😂
@SneeuwPoesjes
@SneeuwPoesjes 2 года назад
Wait till you realize that the majority of rocket science is just fancy plumbing.
@vaibhavbv3409
@vaibhavbv3409 2 года назад
Yeah. The fact that hot water and cold water pipes are just shorted seems like wizardry and rocket science.
@Project_VideoGame
@Project_VideoGame 2 года назад
@@SneeuwPoesjes get 2 liquids to the bottom of a tube uh huh, "Fancy" plumbing
@Priapos93
@Priapos93 2 года назад
Two words: Colin Furze
@orange_cat
@orange_cat 2 года назад
I have some electrical engineering degrees and don't know jack about plumbing. I just call the plumbing guys and pay them, and all is well.
@mittensfastpaw
@mittensfastpaw 2 года назад
I love how he always injures himself or other devices for our entertainment safely. A good man.
@FateBoost
@FateBoost 2 года назад
I read that comment just as he gets to the explosion scene lol
@garyangelstad5212
@garyangelstad5212 Год назад
A word from the wise (and experienced). Honeywell zone valves are quite troublesome. I've had the gear on the motor strip out because it's made of soft material, the motors themselves get weak and wont go far enough to set the end switch. I use caleffi now and haven't had any more issues or callbacks. The actuator units have a lever that releases them from the body without opening the system. Honeywell has two small screws deep inside that make it tougher to change. Caleffi has a higher cv( flow ) rate
@merlin5476
@merlin5476 Год назад
Honeywell & M.K. electrical goods have become fairly unreliable over the last few yrs, but the M.K. prices have remained rather high. ( M.K. & Honeywell are the same same company)
@lookupverazhou8599
@lookupverazhou8599 Год назад
Planned obsolescence.
@callmex5406
@callmex5406 Год назад
Sure thing buddy I could say the same about caleffi, it does have a higher flow rate, but the inverse flow of ac to dc conversion with lower string coils per cubic metre has led to a lot of companies opting for honeywell systems. Not to mention the 8 year old who got electrocuted at 45 meters distance from a caleffi motor last spring which caused a black out in arkansas?
@garyangelstad5212
@garyangelstad5212 Год назад
@@callmex5406 can you provide me with the data on this incident.
@callmex5406
@callmex5406 Год назад
@@garyangelstad5212 obviously the news was taken off the internet after the company issued a media blackout. The courts were in on it.
@lennytheface9601
@lennytheface9601 2 года назад
I love these kinds of videos, where he fixes stuff
@CNoteZzz
@CNoteZzz 2 года назад
That's why I liked this one more than others
@gustavolrcoelho
@gustavolrcoelho 2 года назад
That's weird, most of us like when he blows stuff.
@kettujabamiesukkeliukko
@kettujabamiesukkeliukko 2 года назад
Yeah, these are nice videos along when he builds (and blows up) something
@ClonkAndre
@ClonkAndre 2 года назад
Me too!
@rekis7819
@rekis7819 2 года назад
He fixes stuff?
@AdamHill42
@AdamHill42 2 года назад
8:57 "what are you burning?!?" -Medhi's family every day
@AarishRaja-kj8ic
@AarishRaja-kj8ic 4 месяца назад
Mehdi : What are you burning ?!?! The wire : idk man .
@StefBelgium
@StefBelgium Год назад
This is so interesting my friend. How your investigation drove you to the reason why your AC motors failed at the first place. That s terrific!
@fallingstar7347
@fallingstar7347 2 года назад
Dear Mehdi, thank you for making these videos. I've learned so much in electrical engineering from your videos, while having a laugh from your content. Your content unironically makes my job in engineering easier.
@vampire4312
@vampire4312 2 года назад
As a mechanical designer, I have to admit: Electrical engineering is often basically some kind of sorcery to me. I mean... I get how a lightbulb works... but that's basically it.
@CyberlightFG
@CyberlightFG 2 года назад
Lightbulbs are not that easy any longer.
@mgancarzjr
@mgancarzjr 2 года назад
I had the pleasure of being taught physics by a FermiLab scientist. She was smart enough, and I mean no disrespect she was very smart, to know when I needed conceptual vs practical answers to questions I had about capacitors, inductors, etc. Different people need different approaches to electrical engineering.
@muzallisam5068
@muzallisam5068 2 года назад
mechanical stuff we can actually see things in motion. 1 action cause another. electricity and electronic is like wizardry to me.
@mgancarzjr
@mgancarzjr 2 года назад
@@muzallisam5068 oscilloscopes are the prized possessions of electrical engineers. They make the invisible world of electricity visible.
@LeonardGreenpaw
@LeonardGreenpaw 2 года назад
Hey I work with an electrical engineer and he doesnt even have a simple understanding of how uneven pressing forces would create uneven pressures
@jdatlas4668
@jdatlas4668 2 года назад
Isn't it fun when something like this breaks down? You get all the fun of debugging an issue with an at this point pretty complicated device, all while dealing with the frustration of your heating or whatever other important thing not working...
@goku445
@goku445 2 года назад
Unless it's in winter and you have no heater left.
@jdatlas4668
@jdatlas4668 2 года назад
@@goku445 honestly that comment was like, at least 75% sarcasm. I'm not actually a fan of having to do this sort of thing :P
@goku445
@goku445 2 года назад
@@jdatlas4668 Right. I read too fast your comment. I actually enjoy fixing stuff, that's why my comment.
@NoflectioN
@NoflectioN Год назад
Very cool. I'm an hvac tech ...ive never tore apart a zone valve that far. I fix these things all the time but still learned something today. Cool.
@Zaharon
@Zaharon Год назад
The only time I've taken one apart instead of just replacing the head was when I was a trainee and was instructed to "change the head on that valve". Still remember my bosses confusion 15 years later as to why was the old one in pieces in the box when at first he thought I was wasting time on pissing about. Difference between theoretical knowledge and practical knowledge.
@tim-thetoolman-taylor
@tim-thetoolman-taylor 2 года назад
Every single mechanical engineer who watched his video is mad now. We are mad.
@James66344
@James66344 2 года назад
Whenever I see a big boiler, I always wonder how compact you could get it without taking away functionality. Then I realise that keeping it big and spread out is pretty key to keeping it easily repairable.
@Jmoneysmoothboy
@Jmoneysmoothboy 2 года назад
As long as a child can fit inside we can keep the trai... boiler running forever
@QualityDoggo
@QualityDoggo 2 года назад
Basically the exact opposite of smartphone design!
@kaikart123
@kaikart123 2 года назад
That is why things with "industrial" grade tend to be big for seemingly no reason
@TuxraGamer
@TuxraGamer 2 года назад
@@QualityDoggo yet most people want them thinner and more complex lol.
@machintelligence
@machintelligence 2 года назад
Larger heat exchangers are generally more efficient as well.
@Vesterian
@Vesterian 2 года назад
"WHAT ARE YOU BURNING?" Actually made my day, keep up the great work, iheMd!
@eduardopereira1915
@eduardopereira1915 2 года назад
Mehdi*
@Vesterian
@Vesterian 2 года назад
@@eduardopereira1915 that was the joke yes.
@eduardopereira1915
@eduardopereira1915 2 года назад
@@Vesterian Ok.
@adthya9209
@adthya9209 2 года назад
But what was burning actually?
@merumio
@merumio 2 года назад
ru-vid.com6lrPUb5echQ
@TheTaxxor
@TheTaxxor 2 года назад
Even with the voltage dropping when all motors are running, these motors would also work fine at 22VAC you could still drop the voltage from 31V to 27V, then a single motor would at least only get ~25-26V instead of 29-30
@bluerilius4362
@bluerilius4362 2 года назад
Makes me wonder if they're using an older transformer made for 110 v hence why the higher output on 120 v... or maybe the plumbers that did this are dumb and got the wrong transformer?
@mernok2001
@mernok2001 Год назад
@@bluerilius4362 Could also be a chinese transformer because they mostly rate stuff for 110 or 220 V, not for 115, 120, 230 or 240.
@bluerilius4362
@bluerilius4362 Год назад
@@mernok2001 perhaps that may be
@GartenFallneX
@GartenFallneX 2 года назад
This was one of the best videos ive seen from you. Honestly really awesome to learn about every day powerpixies, that you normally wouldnt know about.
@marsgizmo
@marsgizmo 2 года назад
Fully agree, electrical engineers are on the top! ..we have unlimited access to black magic... 👀
@sn0wchyld
@sn0wchyld 2 года назад
untill we let the magic smoke come out, then we have none :P
@anthonyspadafora1384
@anthonyspadafora1384 2 года назад
I have been installing complexed hydronic systems for 40 years. I would never let an electrician much less an electrical engineer wire any of my systems. lol
@bobvines00
@bobvines00 2 года назад
As a Mechanical Engineer, I'm tempted to ask "a friend" that I know to turn Medhi into a frog! ;) LOL! Of course I wouldn't really do that, but if my friend _did_ turn him into a frog, then he could redo some of Galvani's experiments with electricity & frogs. Seriously though, his troubleshooting was interesting and the repairs appear to have worked, at least until the too-high voltage kills more motors. I half expected him to replace the power supply with a regulated 24VAC PSU.
@sn0wchyld
@sn0wchyld 2 года назад
@@anthonyspadafora1384 What, because we'd be able to point out all the things you've been doing wrong for those last 40 years? :P ;) Sorry couldn't help myself
@muhammadjalal2335
@muhammadjalal2335 2 года назад
Hi
@nazeradom
@nazeradom 2 года назад
This was actually fascinating, I'm finding your home electrical DIY videos to be excellent.
@simpsobriety8326
@simpsobriety8326 2 года назад
6:50 When he wet his skin to see if he would feel anything then he screamed in a British accent😂😭
@pellemus100
@pellemus100 Год назад
I Love you mehdi! I designed particle accelerator electronics for 4 years, and me and my colleagues would watch your videos for inspiration. For example your Jakobs ladder was used as a 1000V power supply for a mock up injection kicker for ISIS Neutron and Muon Source in Rutherford. Keep up the good work, you might be helping more than you know.
@vidhyas4791
@vidhyas4791 Год назад
Cool
@coincoinpower
@coincoinpower 2 года назад
glad to see the mech engineer trolling goes across the Atlantic ocean :')
@ignispurgatorius5297
@ignispurgatorius5297 2 года назад
My thoughts exactly, I felt right at home. ;)
@nikkiofthevalley
@nikkiofthevalley 2 года назад
Same as "yellow chemistry bad" I'd imagine.
@lululombard
@lululombard 2 года назад
I have the same kind of setup in my house except it's from the 80s and with only two zones, I had to replace the transformer and I pretty much ditched all the old electronics to make my own, now each zone is on a relay controlled by Home Assistant and I made my own thermostats powered by an ESP32. All the issues I had before were electrical too!
@ExperimentoLOGY.
@ExperimentoLOGY. 2 года назад
ru-vid.comH3hL08Ka-_4?feature=share
@stormology9230
@stormology9230 2 года назад
ru-vid.comH3hL08Ka-_4?feature=share
@limegreentechnologies8803
@limegreentechnologies8803 2 года назад
Nice
@Gabu_
@Gabu_ 2 года назад
Microcontrollers are the best thing since sliced bread.
@epilepticwizard4800
@epilepticwizard4800 2 года назад
@The Game Shorts 🅥 you've posted this link on every video I've seen last week. It's an ice cream recipe... You're spamming comment sections for an ice cream recipe..
@spud1300
@spud1300 4 месяца назад
These videos are more entertaining than i’d ever have expected! Came here for a patio heater comparison and now I think i’ll stay a while.
@Tonto69
@Tonto69 2 года назад
The casual "What are you burning?" killed me lmfao
@aHUNT3r77
@aHUNT3r77 2 года назад
“Interesting how this plumbing problem turned out to be electrical” Sounds like whatever discipline of engineering that normally does HVAC did their job right, I wonder which types of engineers those are 🤔
@forivall
@forivall 2 года назад
Perhaps it has something to do with machines?
@jrisner6535
@jrisner6535 2 года назад
Mechanical and electrical 😊
@rengar322
@rengar322 2 года назад
@@jrisner6535 drain lines and furnace venting makes them plumbers too
@truthsRsung
@truthsRsung 2 года назад
Cryptographer you are, huh? 😉 Vulcan engineers? German? Japanese? Don't give me any Static, I am trying my best. How about any engineer that knows when to use a normally open circuit over closed, and vise versa?
@HopperNation
@HopperNation 2 года назад
They aren't engineers, they are architects!!!!
@jost3n414
@jost3n414 2 года назад
As a plumber myself, Mehdi actually got most of the stuff right, just wandering who the hell did those pipes, they look so unorganized to me.
@inurokuwarz
@inurokuwarz 2 года назад
Every time I've hired a plumber they'll see something the last plumber did and go "Yeah that's garbage, did you get an idiot to fix it?"
@jost3n414
@jost3n414 2 года назад
@@inurokuwarz exactly
@tarakivu8861
@tarakivu8861 2 года назад
@@inurokuwarz Sounds like programmers too
@willis32
@willis32 2 года назад
@@inurokuwarz You wouldn't get it, its a plumber thing. Just believe us, we mean it.
@bhaktibhandari7379
@bhaktibhandari7379 2 года назад
@@inurokuwarz And then you tell him, that it was he who was called last time 🤣
@samuelatienzo4627
@samuelatienzo4627 2 года назад
2:37 Mehdi is so Canadian 🇨🇦 🍁- “… and nothin’ aye?” 😂😂😂
@AT_Videography
@AT_Videography 2 года назад
9:00 Was the most genuine reaction I have seen from you yet, Mr. Explosion! Priceless!
@Agent24Electronics
@Agent24Electronics 2 года назад
I'd love to know what was burning haha
@AT_Videography
@AT_Videography 2 года назад
@@Agent24Electronics agreed!!
@codecthelios
@codecthelios 2 года назад
That is an impressive heating system. I feel like a cave man with my propane furnace
@Mike__P
@Mike__P 2 года назад
But I bet yours works.
@MyNotSoHumbleOpinion
@MyNotSoHumbleOpinion 2 года назад
This heating system is barely the minimum requirement in Europe!
@g3th_
@g3th_ 2 года назад
@@MyNotSoHumbleOpinion Yeah, not at all
@Apollo-Computers
@Apollo-Computers 2 года назад
I have a kerosene furnace....
@MyNotSoHumbleOpinion
@MyNotSoHumbleOpinion 2 года назад
@@g3th_ then let's say in civilized Europe. in Italy every replacement of the heating system must be done in this way with at least a condensing or biomass boiler! Each new construction must instead have at least one hybrid system with a water heat pump, solar panels and photovoltaic panels!
@ShadowCammando24
@ShadowCammando24 2 года назад
I love how entertaining he makes these videos. Truly one of a kind channel. Mehdi makes learning fun. ❤️
@petesshed8422
@petesshed8422 Год назад
Hi Medi, I’m a commercial engineer and I do a lot of pipework design - Re the pipework: The installer has tried to create a basic low loss header but (for many reasons) the primary pipework appears to be undersized and the connections for flow and return are too close together. Also there should be a by-pass between the circulator and the zone valves. I could write an essay on the correct way to do it… but if it’s working, please don’t start re-plumbing it! 😂😂😂
@kolyngay-message6710
@kolyngay-message6710 2 года назад
at 10:29 I'm like, "that is a stupid design". A few seconds later I was glad to hear you thought so too
@_John_P
@_John_P 2 года назад
As an offended Mechanical Engineer, I'm pleased to see that the problem was electrical as usual.
@bowesterlund3719
@bowesterlund3719 2 года назад
Hahahaha made my day (mechanical engineer)
@MichaelSteeves
@MichaelSteeves 2 года назад
As an electrical engineer -- I feel validated ;)
@davidh.4649
@davidh.4649 2 года назад
Michael Steeves, same here. And I'm certain Mehdi's heirarchy opinion is completely unbiased. 😅
@sldwnr98
@sldwnr98 2 года назад
As an astrophysicist I do not.
@reversedon8698
@reversedon8698 2 года назад
As mechanical engineer student i feel insulted. i did take extra electrical classes tho.
@reversedon8698
@reversedon8698 2 года назад
@@benjamin4321 and structural engineers are below janitors lmao
@mikkelbreiler8916
@mikkelbreiler8916 2 года назад
As an IT engineer I felt like I ducked in time.
@microwave221
@microwave221 2 года назад
I start getting anxiety as soon as the cover comes off and the more dangerous parts start getting yanked around. I know it's intentional, but it still gets me
@travelbugse2829
@travelbugse2829 2 года назад
You should, with your moniker, look at Big Clive's video on wood-burning art using high-voltage transformers. It would, er, relax you...
@kingiam9271
@kingiam9271 Год назад
Lol i remember when I used to be like that
@theaviator1152
@theaviator1152 2 года назад
Mehdi: Electrical engineers are at the top of the hierarchy, plumbers are at the bottom Mehdi two seconds later: *Points to plumbing* “I don’t know what this magical device is” 💀
@hugofontes5708
@hugofontes5708 2 года назад
Turns out it was a water freewheel diode
@LazuliteLol
@LazuliteLol Год назад
@@hugofontes5708 can you make a full bridge rectifier out of that?
@Mr.Sparks.173
@Mr.Sparks.173 Год назад
​@LazuliteLol maybe. But most water lines are already direct current systems. So there's nothing to rectify.
@jefffan9379
@jefffan9379 2 года назад
It would be awesome to watch Mehdi fix the underlying issues that caused this problems. Run a dedicated 15 Amp line in the walls replace the transformer with a power regulator, or alternatively completely over engineer a system from the thermometers to the valves changing the signal to digital or at least DC
@Pentium100MHz
@Pentium100MHz 2 года назад
You can also probably get the motors rated for mains voltage and use the 28V to control a relay. Or just unwind a few turns from the transformer (or wind a few turns backward) so the voltage at full load is lower than 24V (use an autotransformer to find out the minimal voltage at which the valves still work and just use slightly higher voltage.
@cptrelentless80085
@cptrelentless80085 2 года назад
My radiators just have a mechanical thermostat on each one.
@machintelligence
@machintelligence 2 года назад
I worked on an old 5 zone system that had 5 circulating pumps. Expensive, but it has super redundancy. One of the zones had a high velocity pump. Then someone replaced it with a standard circulating pump. The zone for the bedrooms (which were at the far end of a sprawling house) was not keeping that end of the house warm in really cold weather.
@masterdirk101
@masterdirk101 2 года назад
yeah, and then when they move the new owners need an electrical engineer to fix everything that he over engineered because your average plumber/hvac guy isn't going to want to touch it.
@goku445
@goku445 2 года назад
That was honnestly disappointing when he said : "Done!" And we saw nothing. wtf
@Lampe2020
@Lampe2020 2 года назад
8:54 I had to laugh internally when I saw it smoking and Mehdi didn't notice ;) The angry (not scared at all) response to the smoke: "What are you burning?!?" (with a "Why do you allow yourself to burn?!?" between the lines)
@Lampe2020
@Lampe2020 2 года назад
ru-vid.comUgkxDSHMD50O3HOqk5imXehDZN3caF4WiqtT
@baibhavpalit1085
@baibhavpalit1085 2 года назад
At 5:58 get ready for some good Electroboom style jumpscare...!!
@lonely_7891
@lonely_7891 2 года назад
6:00
@steersfamily9736
@steersfamily9736 Год назад
Reminds me of that one time he pulled the auto transformer and says it “””REDUCES””” the voltage
@crisenpuer
@crisenpuer 9 месяцев назад
7:54 "and they say high voltage is bad" got me laugh soo hard
@Alejandro_BoniIIa
@Alejandro_BoniIIa 2 года назад
You know, I took an electrical engineering final yesterday, and it was nowhere near as fun as this channel
@tubanbodyslammer9125
@tubanbodyslammer9125 2 года назад
I love slowing down unexepected events to see if people were expecting them. 5:50 was completely genuine
@ConorV
@ConorV 2 года назад
I had this exact problem at my parents house a while back. The motors ran really really hot when they were on and a couple wouldn't work at all... Now I know why. Thanks for sharing your findings (also as an EE myself I died with the MechE joke...uh I mean fact)
@SLlM4
@SLlM4 2 года назад
Electrical engineers are basically plumbers... gotta make sure everything is flowing, no leaks, and if something breaks there's going to be a lot of damage to your house.
@brunobarks6544
@brunobarks6544 2 года назад
I never knew watching someone's frustrations could be so rewarding. Lol. Thanks for that , and the belly laughs too. Much love. God bless 🙏
@ChucklesTheBeard
@ChucklesTheBeard 2 года назад
10:58 This system resets itself to a known state; all valves automatically close completely upon loss of power, it's not possible to end up half-open. Using D/C motors and limit switches in the "closed" position could do the same, but then you need more I/O pins on the controller ($$), more switches ($), a decent power supply instead of just a cheap transformer ($$), more code to handle the "closed" switches (which means more potential bugs & more programming $$$$$)... It's the cheapest system that gets the job done and mostly doesn't fail before the warranty expires. Looks like a good engineering job to me! :D
@iffracem
@iffracem 2 года назад
But the circulation pump would shut down in a power outage, who cares if the valve is open in a closed loop system? A simple check valve will stop any water reversing flow. These days (alleged chip shortage aside) micro-controllers are dirt cheap, most commercially available (heck, even hobbyist versions) have enough IO pins that can be multiplexed to work very cheaply. The coding cost is debatable as well, and entirely dependent on the number of units sold/installed. Here in Australia such water based heating systems are rare, so yeah, all components inc programming would be expensive, but I believe pretty common in the northern hemisphere so less of an issue. And your assumption of a decent power supply being more expensive than the potential "life of product" power drain of this cheap alternative could be argued. "mostly doesn't fail before the warranty expires" is cold comfort (pun intended) and a poor metric... good for the seller/manufacturer I guess, but this planned obsolescence is bad for the planet, as it needs yet more replacement parts to be made and consumed over the actual life of the entire installation.
@Mkananoja
@Mkananoja 2 года назад
so add bit of code or even circuit logic that upon restart, drive all valves to close/open for few second and then normally control them.
@jdkap201
@jdkap201 2 года назад
imo you really don't need much I/O Pins, just rs-flip-flops, a shift register and a timer. Heck, you could even use an fpga for all that. Implement a proprietary or public open source serial protocol and all you'd need are like two I/O pins at minimum, better yet four as twisted pairs for RX and TX.
@primus711
@primus711 2 года назад
Why not relays?
@gorman2001
@gorman2001 2 года назад
It wouldn't even need any electronics, just a single "horseshoe" rocker double pole switch would work
@crabofchaos7881
@crabofchaos7881 2 года назад
Every video on this channel makes me remember that day when I was putting fire safety pallets into sockets in a school and got shocked doing this in front of a whole class. Electroboom is the same idea, but the scale is way up.
@hammondjones9484
@hammondjones9484 Год назад
Absolutely one of the best teachers I’ve ever had
@henriquelopes5080
@henriquelopes5080 2 года назад
I mean, rocket science is basically plumbing explosions, so I think having plumbing and rocket science on the same level seems fair...
@inurokuwarz
@inurokuwarz 2 года назад
I like that doctors stayed on the same teir XD
@raffaele94full
@raffaele94full 2 года назад
i mean, also electrical engineering is basically plumbing for electrons XD
@Greenteabook
@Greenteabook 2 года назад
Watching your near misses helps calm me while I do simple electrical tasks around the house. As long as I verify the circuit is dead and be mindful of the potential of injury I feel much more confident I won't burn the house down.
@Narcaleptix
@Narcaleptix 2 года назад
Crazy to me how far your production value has come, been watching for years, super impressive. Best of luck to you!
@gefginn3699
@gefginn3699 2 года назад
You are one of my most favorite RU-vidrs. You showcase a brilliant combination of humor/ comedy with how-to knowledge. ⭐😇
@EVguru
@EVguru 2 года назад
Fail safe valves, what a concept! This design always uses the full travel of the valve and is very reliable on the 'wet' side. The proportional valves tend to be much less reliable, especially if the control system does not have routines that use the full travel regularly. As a former electronics engineer, who used (amoungst other things) to maintain the control system in a glasshouse comples with over 120 indiviual climate controlled compartments, I know a fair amount about these valves and their failure modes. Most of my callouts were to find that the control system was fine, but there was a mechanical problem, or that the control gear (the electricians responsibilty) was at fault. One proportional valve design that I liked, but was let down by a poor control board design, used a solenoid to pull the valve open, with the coil being phase angle controlled. The response was very non linear, but we had flow and return temperature sensors, so the non linearity would be taken out by the PID loop.
@Loran425
@Loran425 2 года назад
Was hopping down to look for exactly this comment, simpler mechanical design by leaving the motors live and if the system ever failed electrically the valves should close. Makes me wonder if there is an elegant way to reduce/eliminate the power use without losing the failsafe.
@sootikins
@sootikins 2 года назад
@@Loran425 Oh, there is a way: pneumatic actuators with spring return to closed. The obvious problem is the need for compressed air to operate the actuators.
@metanevets91
@metanevets91 2 года назад
@@Loran425 a small latch on the spring actuated by a small electrical current? Basically, add something that can be controlled with the smallest possible electrical circuit to reduce the power needed. Or, some failsafe that is sensitive to a state change in the electrical system. I don't know enough to imagine what that would be, probably some digital doohickey.
@mrlazda
@mrlazda 2 года назад
@@Loran425 internally piloted solenoid valve have much less power consumption and have exactly same behaviour as this.
@frederf3227
@frederf3227 2 года назад
@@Loran425 My old dishwasher door actuator uses a wax motor so you get it hot and it opens by thermal expansion. Without power the wax cools and contracts. It's not critical these valves open lightning fast so why not. All they are is a heater, wax that expands under heat, and a spring. On the plus side the valves would close suuuuper slow so as to never slam shut.
@paranoia0like0hell
@paranoia0like0hell 2 года назад
Maybe they just want the valves to close by themselves when you have a power outage, kinda like a fire door that is normally held open by an electro magnet ?
@ML_314
@ML_314 2 года назад
I was just about to write the same :)
@luispereira3
@luispereira3 2 года назад
Correct. They also need to keep it simple with as few parts as possible as must be reliable for hundreds of operations.
@a51mj12
@a51mj12 2 года назад
Thats exactly why such design is used, im stunned this EE guy can't realize such simple concept...
@Satyaprakash81102
@Satyaprakash81102 2 года назад
Why does a valve needs to be closed during power outage? The water supply/circulation has stopped as the circulation pump has stopped too.
@wecsam
@wecsam 2 года назад
Why would the valves need to close by themselves during a power outage?
@user-ls7hy7gu4t
@user-ls7hy7gu4t 9 дней назад
I love the timing ! Motor : .... [ just smoking for no available reasons... ] Medhi : WHAT ARE YOU BURNING !
@curtissmith711
@curtissmith711 5 месяцев назад
I salute to this guy because he puts himself through pain and more pain and might get shocked multiple times just for us to learn things I salute to this guy
@owwerlord6921
@owwerlord6921 2 года назад
1:12 as a mechanical engineer my cold steel heart feels hurt
@tl1882
@tl1882 2 месяца назад
better than architects, they didn't even make it on the list
@vidhoard
@vidhoard 2 года назад
I really loved this video. Troubleshooting, fixing, explaining... felt like a mystery puzzle and I loved it.
@-ColorMehJewish-
@-ColorMehJewish- 2 месяца назад
I absolutely give plumbers a lot of credit. That is not easy work, and not fun either. I have a lot of respect for what they do (some, not all)
@Deathknight1700
@Deathknight1700 Год назад
I like how they put the electrical box underneath the pipes too. Hopefully one of the pipes don't bust or start leaking right over it!
@iestyn129
@iestyn129 2 года назад
I think a follow up fixing/upgrading the power supply to run a constant 24v would be pretty cool
@ortholux2343
@ortholux2343 2 года назад
Seems like a no brainer
@PHamster
@PHamster 2 года назад
GreatScott is yelling at the screen at 11:54 for using those nuts instead of Wago blocks
@SinnerDeveloper
@SinnerDeveloper 2 года назад
The power cord cut in half killed me😂😂😂
@michaelgroob3760
@michaelgroob3760 2 года назад
The added complexity of something that used to be simple just furthers my need to live in a cave.
@yuvalkaroly4362
@yuvalkaroly4362 2 года назад
I work at a motor company. I've heard a bit of an urban legend that once, many years ago, there was a tiny strand of copper causing a short that stopped a motor from functioning. The fix? Shock the sh*t out it and burn out the short. Maybe that's what happened to you? Who knows
@ScottsSynthStuff
@ScottsSynthStuff 2 года назад
*looks in horror at wire plugged into 110VAC socket with bare wire nuts dangling in the air*
@ExperimentoLOGY.
@ExperimentoLOGY. 2 года назад
ru-vid.comH3hL08Ka-_4?feature=share
@Novashadow115
@Novashadow115 2 года назад
You can feel the sketchyness ooze through the screen
@AndyFletcherX31
@AndyFletcherX31 2 года назад
I didn't see any earthing either
@marcogenovesi8570
@marcogenovesi8570 2 года назад
that's why you don't let plumbers do electric work
@zebo-the-fat
@zebo-the-fat 2 года назад
No problem, it's ony Americam wimpy 110 volts, try getting away wiyj that on 240volts!
@DUSKINMODS
@DUSKINMODS Год назад
I could watch this man burn sh*t all day. The best (and funniest) education.
@TheHire99
@TheHire99 2 года назад
The "short-circuit" is the correct way to plumb that boiler. It is called primary-secondary pumping\piping. There are two circulator pumps. The primary pump circulates water through the boiler's heat exchanger. The secondary pump circulates the water through each of your zones for heating. This primary pump is actually located on the inside of your combi boiler. What I did notice is that the zone valves are not on the correct end of the zone piping. Zone valves should be installed on the return side of the piping so as to not to cause water hammer when the zones shut. Because the pump is creating head pressure and pumping into the zone valves, there will be a spike of pressure when the valves shut from the head pressure of the pump. This can result in a knocking noise whenever any of your zones shut. I would recommend moving the zone valves to the return side of the zones if possible. The voltage you are getting from the power supply should not really hurt those motors too much. Its pretty much a nominal voltage difference from what the motors are rated for. Most zone valve panels like the one you have output 27-26VAC to the valves. All the end switches on each zone valve are usually wired in parallel to the T-T (AKA thermostat) terminals on the boiler signaling the boiler to run. Each thermostat makes and breaks the 24V power going to each of the corresponding zone valve motors by disconnecting one leg coming from the secondary side of the transformer. If you continue to burn out that same motor I would recommend replacing the valve body and not just the motor. Usually what happens is mechanical resistance occurs at the valve stem over time from scale/buildup inside the valve. This scale/buildup will cause the motor to prematurely wear out over time. This advice is coming from a professional mechanical contractor/HVAC tech with 12yrs experience with hydronic/steam heating. Hope this helps you out.
@Shubham.Kochhar
@Shubham.Kochhar 2 года назад
dam, this is one of few videos that despite being 14mins long, finished in seconds.
@hebl47
@hebl47 2 года назад
2:00 Seems fair. Rocket science does involve a lot of extreme plumbing after all.
@commanderguy-rw7tj
@commanderguy-rw7tj 2 года назад
damn the overlay at 9:21 tricked me real well, you can for sure leave it like that !
@KitsuneAlex
@KitsuneAlex 2 года назад
2:00 This setup is a passive mixer; it reduces/balances temparature by joining the forerun and backrun of the loop at some point. Most of the time, there's also a reduction inside the plumbing where the two pipes join to reduce flow rate.
@fouadayoub1285
@fouadayoub1285 5 месяцев назад
if medhi was an aerospace engineer he would know that!! (taught in thermo 1)
@PojdmeMluvit
@PojdmeMluvit 2 года назад
I love this rivality between mechanical and electrical engeneers !
@AndrewNicholsSeattle
@AndrewNicholsSeattle 2 года назад
Loved this Mehdi, really happy with all of these home DIY repair videos that just extend the EE knowledge to other areas. Great stuff. Thanks for encouraging me to repair things and to understand complex systems.
@weedchild5871
@weedchild5871 2 года назад
As an electrical engineering student, I absolutely agree with that dominance hierarchy.
@jkelley012
@jkelley012 Год назад
Never forget, rocket science is just plumbing with extra physics involved
@m1ke88
@m1ke88 2 года назад
The pipework arrangement is based off what's called a Low Loss Header. I'm always amazed how folk in North America are so amazed by combi boilers. Viessmann and such have been around for many years in the UK. I've been to Viessmann's HQ in Germany for training courses too.
@AB-ld1rp
@AB-ld1rp 2 года назад
the electrical box at the end was the cherry on the pie. Can I say that I loved to see the horror?
@jonathanlitz2018
@jonathanlitz2018 2 года назад
11:09 24VDC 60HZ *laughs*
@windowsxpmemesandstufflol
@windowsxpmemesandstufflol Год назад
Seems legit
@danek_hren
@danek_hren 11 месяцев назад
How-
@ATTIQOP
@ATTIQOP 14 дней назад
Wait what I have also i9 14th pic on my pfp in discord
@boonhobo
@boonhobo 2 года назад
Fixed my landlord's A/C unit, a wire came loose that carried 30 VAC. Thanks to this video, I took a chance with my multimeter to mess around with 30 VAC and re-established the connection. Otherwise I'd would not have taken that opportunity and they'd be down $$150-400 calling a repair guy. Thanks Medhi. Not an electrical engineer. Studied chemical with a specialty in in biochemistry and some background in voltaics due the nature of my current work.
@werdwerdus
@werdwerdus 2 года назад
please release a short or a 2nd channel video fixing the plumber wiring!
@murderer2022
@murderer2022 2 года назад
@Don't Read My Profile Photo i wont lol.
@insolencePL
@insolencePL 2 года назад
The "shorted" hot water pipe is a bypass. It mixes super hot water from furnace with cold water. This way your radiators are safe to touch. You can think about this like voltage divider. Ofter there is a valve working like potentiometer so you can dial up output temperature.
@ferrumignis
@ferrumignis 2 года назад
Normally there will be a thermostat in the boiler to regulate the output temperature. Pretty sure that loop is there to enable continuous flow even if all the heating circuit valves are closed.
@kentahirono
@kentahirono 2 года назад
It also make the return water a bit warmer when goes into the hot boiler parts and reduce temperature shock.
@ThomasBomb45
@ThomasBomb45 2 года назад
Lol what
@toddcoonradt6174
@toddcoonradt6174 2 года назад
It is a bypass, but not for the reason you mentioned. The closely spaced tees provide what we call ‘hydraulic separation’. By doing this, the water flow through the boiler remains constant, regardless of how many zones are turned on.
@polandball9937
@polandball9937 2 года назад
I doubt that its used to lower the temperature since its a gas boiler that can just turn on/off or modulate when necessary. Such a precaution is only required if you have a wood furnace or have a heater that heats up a seperate tank with the water inside. This would be one of the reasons why you would require a bypass here
@miknord5493
@miknord5493 Год назад
THE MOTORS ARE AMAZING! 12:00
@mfx1
@mfx1 2 года назад
The switch in the valve is a "call for heat" signal to the boiler when the valve is open, so as long as the valve and it's corresponding thermostat/timer are both "calling for heat" then the boiler will fire up.
@akhtarkh
@akhtarkh 2 года назад
The bypass/short circuit path has a pressure relief valve in it. In case the water gets very hot and the syatem pressure increases, the bypass valve opens to inlet.
@masterdirk101
@masterdirk101 2 года назад
The supervent closest to the bypass actually just removes air from the system, the pressure relief right next to it dumps water into a drain.
@marco23p
@marco23p 2 года назад
Why would it connect to the inlet? I think it should vent to atmosphere / drain instead. The pressure in the system can still rise otherwise.
@masterdirk101
@masterdirk101 2 года назад
@@marco23p it doesn’t. The big thing with Honeywell on the side just vents air that gets trapped in the system the pressure relief to the right of that just dumps water down the drain, which isn’t great as you’ll never know when it’s hitting pressure
@kaponekherkowitsch6317
@kaponekherkowitsch6317 2 года назад
I suppose the motor fight against the spring and button all the time to have a fail-safe setup. If the power is lost or a motor dies, all valves close.
@ferrumignis
@ferrumignis 2 года назад
Neither valve position is "safer" than that other tbh. It's is a legacy system that was designed for least possible complexity; voltage applied valve opens, voltage not applied valve shut. These would traditionally have been controlled by a simple bi-metallic strip style thermostat.
@bluerider0988
@bluerider0988 2 года назад
@@underdweller If the thermostat fails why would the boiler continue to run?
@danieljensen2626
@danieljensen2626 2 года назад
@@underdweller The heater needs electricity to turn on. If the motors don't have power the heater won't have it either.
@AsifAlZubayerSwapnil
@AsifAlZubayerSwapnil 2 года назад
@@danieljensen2626 The motors can lose power independent of the heater, or fail themselves just like what happened here.
@kennybiel9688
@kennybiel9688 2 года назад
Close but it's precisely because there is no power when the thermostat is *not* calling for service.
@florinmoldoveanu6116
@florinmoldoveanu6116 2 года назад
Letting an electrical engineer unsupervised will either result in fire or black magics, there is no other option
@anthonyspadafora1384
@anthonyspadafora1384 2 года назад
The "short circuit" Is what is called primary secondary piping. This piping arrangement decouples the flow rates from the boiler pump and the zone pump. You can override the zone valves with the little levers protruding from the side of the zone valves. Your zones have no flow valves and you do not have a variable speed pump to maintain pressure. In other words if all the zone valves are open the water will take the path of least resistance. add flow valves to each zone return...set the variable speed pump for 8 psi...open one zone at a time and adjust flow valve to obtain a 20 degree delta T. None of the trades you mentioned do this type of work properly. What you need is an HVAC hydronic tech. We are very few in the US but very plentiful in Europe.
@im1random263
@im1random263 2 года назад
So is it a really short single pipe heat exchanger?
@anthonyspadafora1384
@anthonyspadafora1384 2 года назад
@@im1random263 www.caleffi.com/sites/default/files/coll_attach_file/idronics_15_na.pdf This is a really well done article on this. Enjoy
@anthonyspadafora1384
@anthonyspadafora1384 2 года назад
@@im1random263 p.27
@im1random263
@im1random263 2 года назад
@@anthonyspadafora1384 🤔
@sbeb8414
@sbeb8414 2 года назад
when Mehdi does anything sudden I always flinch, not because I'm scared *of* him, but because I'm scared he's going to get an electric shock.
@ortholux2343
@ortholux2343 2 года назад
That's his signature. I'm pretty confident he's smart enough to stay away from lethal zaps.
@chaoswraith
@chaoswraith 2 года назад
Its all for show
@rasmus1600
@rasmus1600 2 года назад
9:09, we're currently calculating this stuff in class. I feel so clever being able to understand that.
@matthewbertrand4139
@matthewbertrand4139 Год назад
as a student studying chemical engineering i was going to complain that it didn't make it into the hierarchy, but then i remembered that chemical engineering is just extreme plumbing. so we did make it into the list, above mechanical engineers. score
@AxolotlAndy
@AxolotlAndy Год назад
Plumbing is just the base of it all apparently. Aren’t electrical engineers and electricians just electron plumbers?
@onemoreguyonline7878
@onemoreguyonline7878 8 месяцев назад
6:50 "and it will heeurt" hahaha the hidden puns in your videos are great
Далее
Making HIGH VOLTAGE SUPPLY, there was an attempt…
15:45
OBLADAET - BARMAN
03:06
Просмотров 140 тыс.
Making 5 Things from a Broken Hair Dryer
12:04
Просмотров 2,3 млн
Repairing Faulty Ground Fault Failure
16:17
Просмотров 851 тыс.
Installing an Outlet… For a Toilet Seat?!
14:45
Просмотров 1,2 млн
So Many MISERABLY FAILED LED Lights
12:07
Просмотров 1,8 млн
ELECTRIC VEHICLES & My Tesla Model 3 Review
19:04
Просмотров 1,6 млн
Making Cooler/Generator with Thermoelectric Device
14:37
Making Wooden Gates for My House
24:18
Просмотров 1,4 млн
How Safe Is the SHOWER HEAD OF DOOM?!
10:55
Просмотров 6 млн