A selection of some of the connectors we use on jobs like The Royal Edinburgh Military Tattoo to distribute power and data around the site.
The popular Socapex connector is one that just fitted the bill at some point in the past and became a standard within the industry, but it's what I would refer to as a grandfathered connector. One that might not be chosen these days because it has a few shortcomings that are tolerated. The main one is the lack of anti-tracking barriers that means they are very susceptible to internal tracking and arcing when they get wet. Something that happens a lot on exposed outdoor events. They also have an ungrounded metal shell with phase conductors in its vicinity, which means care has to be taken handling them if any water gets involved.
They also have an aluminium threaded locking system that tends to get scuffed up over time and it's important to make sure they have all been screwed together completely before powering the rig, as some casual stage crew don't fully understand the importance of a full solid connection. (The pins can arc and burn damaging both connectors.)
Ceeform connectors are one of my favourite outdoor connectors for general power distribution. They're cheap, rugged and have a very high tolerance to water ingress due to the use of pillars, barriers and stand-offs that reduce the risk of a carbon tracking path forming when water enters and then dries out again slowly.
They do a good job of sealing against most water ingress and grip the cable firmly. Some versions have a simple spring/wedge contact system and latch for both halves of the connector that allow very fast termination. They're available in single phase and three phase 16A, 32A, 63A, 125A and higher versions, although the higher current ones require a lot of force to mate and separate. there's also a colour code and keying system for different voltage versions.
The powercon are a nice connector but have to be used with a full understanding of their limitations like any other connector. They offer an easy way to distribute power between low current equipment in a compact form.
If you enjoy these videos you can help support the channel with a dollar for coffee, cookies and random gadgets for disassembly at:-
www.bigclive.com/coffee.htm
This also keeps the channel independent of RU-vid's advertising algorithms allowing it to be a bit more dangerous and naughty.

Наука

Опубликовано:

 

23 авг 2018

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 529   
@SpecialEDy
@SpecialEDy 5 лет назад
I see impressive connectors like this at work every day. I'm at Mouser Electronics.
@IncertusetNescio
@IncertusetNescio 5 лет назад
2 min. 45 sec. to coworker shenanigans. That's a new record!
@tncorgi92
@tncorgi92 5 лет назад
I wonder how many times he's had to restart his videos because of coworker shenanigans!
@MatthewCobalt
@MatthewCobalt 5 лет назад
Actually it's 2"40'. But close enough.
@Chickey
@Chickey 5 лет назад
2"36' if you’re being a pedant...
@nickkirton9579
@nickkirton9579 5 лет назад
You're
@Chickey
@Chickey 5 лет назад
Nick Kirton another pedant. 2”45’ was as good a time frame as any was my point. Corrected just for you though ;-)
@h0dgep0dge
@h0dgep0dge 5 лет назад
This is so lovely. I live in the US, but I worked the Fringe for Gilded Ballon many years ago. Seeing 16a Ceeform sitting on a flight case while hearing a Scottish voice and pipes just warms my heart!
@StrathpefferJunction
@StrathpefferJunction 5 лет назад
*Scottish voice
@krashd
@krashd 5 лет назад
Did this fella just refer to our people as a drink? :D hehe
@sheriholder273
@sheriholder273 5 лет назад
Big Clive. I was able to"fix" a water distiller that burned out the on/off switch because of you. I used your logic found the problem and fixed it. Thanks big guy. I wish I was as trained and adept at electronic issues as you.
@robertsmiczsmiczamplificat593
@robertsmiczsmiczamplificat593 5 лет назад
S Holder . You made a great start. It just takes time brother. Get in the trenches and you will learn more then you can imagine. Like you did. Don't be afraid to try. Just be careful. Cheers.
@sheriholder273
@sheriholder273 5 лет назад
@@robertsmiczsmiczamplificat593 I am careful. I fear and respect electricity. I did a small circuit in our barn. A breaker box and 3 receptacles on 110V. I think I read the chapter in the book 4 times to make sure I didn't screw up. But FYI, I am of the womanly persuasion so it's sister, not brother.
@sheriholder273
@sheriholder273 5 лет назад
@@mistaowickkuh6249 I never work on anything"live". And after repair I am at a safe distance.
@Kineth1
@Kineth1 5 лет назад
S Holder another good idea that sounds like showing off, but is actually for safety: Work with one hand behind your back. Not necessarily behind your back, but only one hand in the electrical stuff at a time. If you do make a mistake, and get a shock, you've only got one hand in circuit, and you're much less likely to jump through your heart.
@HighestRank
@HighestRank 5 лет назад
Sooner or later, somebody's going to immerse their finger in that water or touch its spigot. "staying back after a repair" only works for a short while, unless you'd only be waiting for a guineapig.
@nathanemke
@nathanemke 5 лет назад
Really love these industry videos, Clive. Starting off as a theatre technician working in lots of small scale theatre. Really informative of what’s out there in the big scale.
@mattikaki
@mattikaki 5 лет назад
I was working in MTV Finland 1975-2001 and we had RCA TK-45 color cameras which had very thick camera cable having hundreds of pins. Quite often I had to repair those. Naturally the fault usually was in the center pins and I had to remove huge amount of pins before I could fix the problem.
@alexdavies7112
@alexdavies7112 5 лет назад
That sounds like a challenge
@aleksandersuur9475
@aleksandersuur9475 5 лет назад
Harting is a lego, you order housing, internals, contacts, accessories separately. You basically compile your own custom connector. You can have whatever in there, signal, power, data, fiber optics, pneumatics, coaxial, pretty much whatever you can think of. The trick is to keep track of what series connector parts you use, in what order they go together and what the actual part numbers are. Although, it must be noted, putting pneumatics in a same connector with electricity is generally a bad idea, it sometimes happens that instead of air you get oil or water from somewhere upstream. www.harting.com/sites/default/files/2017-11/Han-Pneumatik-Modul_Hint_0.jpg
@krashd
@krashd 5 лет назад
Harting looks amazing!
@DUIofPhysics
@DUIofPhysics 5 лет назад
Air? let's put water cooling through the same cable :>
@aleksandersuur9475
@aleksandersuur9475 5 лет назад
Tube is a tube, you can put strawberry syrup through it for all it cares. It's just that in the unlikely event of a leak, an electrical connector is one of the worst places it could happen at.
@DUIofPhysics
@DUIofPhysics 5 лет назад
Never thought to test the heat transfer values of strawberry syrup... I wonder if it's better then water for cooling... good idea!
@KillerSpud
@KillerSpud 5 лет назад
I do like speakon and powercon connectors, they are quite satisfying to plug and unplug.
@Anvilshock
@Anvilshock 5 лет назад
It's the grown-man's fidget spinner!
@thavinator
@thavinator 5 лет назад
The new PowerCON TRUE1 connectors are even better! They have a nice Snap! when the terminals disconnect as part of the break-under-load capability.
@dadjake
@dadjake 5 лет назад
They also don't unplug when you don't want them to :3
@dalekrone4335
@dalekrone4335 4 года назад
@@thavinator as a video tech I can agree lol i love the audible click and feel
@qwertos
@qwertos 5 лет назад
Back when I was doing tech in school, the high school theatre used NEMA L5-20 and the middle school used stage pin *shudders*. When ever equipment moved from one space to the other (somewhat often), we'd either end up lugging a stack of adapters everywhere or spend a couple hours re-terminating everything.
@bellphreak4370
@bellphreak4370 5 лет назад
CEE connectors are commonly used in datacenters to distribute 16/32A single phase and 16/32/65A three phase. And all construction work is done with the same CEE connectors (distribution boxes and cables). This makes CEE the most widely used standard in this part of Europe for almost anything (events, congresses, construction, datacenter, telco, etc). I haven't seen the old (pre CEE) connector in a while, guess it's phased out completely. I'd love Neutrik' PowerCon due it's size and locking. Compared to IEC C13/C14 (servers/networking), which lacks that (as official standard, there are some clips on some hardware). In datacenters Cat5(e) is used for RS485 and Ethernet (IP) to communicate with PDU's (power readout and on/off). Harting is used in the entertainment industry, but shifts to (ethernet or DMX over) Cat5(e). Since controllers are cheaper then (a lot of) copper cable used with Harting. Looks like more and more industries use the same standards (where possible).
@JamEngulfer
@JamEngulfer 5 лет назад
Yeah, I recognise it from server cabinet power cables
@justjoe7313
@justjoe7313 5 лет назад
Very interesting look into one more job and it's tools! Thank you, Big Clive, you are a treasure!
@kevanshaw6778
@kevanshaw6778 5 лет назад
Hey I was the lighting tech who took the first ever Socapex cabled rig out on the road! Peter Straker's only tour as a "pop star" paid for by his then partner Freddie Mercury in November / December 1978! This was a Showlites innovation and that first rig ran 8 circuits per connector with 3 common earths and 10' ( 3M ) IWBs ! The first rig had 6 par64 and 2 Patt 764 profiles on each bar. These were really unwieldy and not a realistic one man lift! we learned on that tour that we should go with 6 lamp 8' bars which became standard thereafter and we re-wired the socapex distributions accordingly! Please contact me directly if you want more history from those days
@eideticex
@eideticex 5 лет назад
These are connectors I have been considering setting up for my tools. My woodshop class in HS had similar connectors which were compatible with a wall jack if you flipped the retainer lock back out of the way. Each stationary tool and table had a 6-way bolted onto it somewhere to plug loose tools like palm sanders in. And my favorite feature regardless of cable tech, individual breaker switches on each port with status lights: flashing green in use, green for safe to use, yellow for fault and red for non-functional. Majority of the time faults were idiots tripping breakers and moving to a new port instead of just resetting the breaker.
@Anvilshock
@Anvilshock 5 лет назад
It's worth keeping an ion! Also, the 4-pin Hartings run under "Han 3A" and are in Harting's active portfolio. Cheers!
@brandonmartin-moore5302
@brandonmartin-moore5302 5 лет назад
Ooh, that pun.
@Chriva
@Chriva 5 лет назад
Bagpiiiiiiipes!
@tentringer4065
@tentringer4065 5 лет назад
Even better, distant bagpipes.
@olthdorimirth6055
@olthdorimirth6055 5 лет назад
Omf... I'm not the only one who heard 'em.
@elitearbor
@elitearbor 5 лет назад
I though perhaps Clive was gassy.
@jaytee8188
@jaytee8188 5 лет назад
Whenever I watch any of Clive’s videos I hear bagpipes in the background.
@scwfan08
@scwfan08 5 лет назад
Dudelsack
@timjennings4314
@timjennings4314 5 лет назад
Holy this is amazing. I didn't know you were a lighting tech. I would love to see you rip in to some HMI ballasts and take apart some head cables.
@KireTheCat
@KireTheCat 5 лет назад
in theatres in the US, we tend to use Stage Pin for lights like parcans, and then dmx+powercon for any type of intelligent light
@xanataph
@xanataph 5 лет назад
Nostalgia! Very reminiscent of the stuff I used to work with when I did time on a sound & light crew in my old hometown. A part of my life that is rapidly slipping into the past. We used the Socapex connectors for both sound systems & lighting. Have spent many an hour soldering both multicore cables into those and taking out tails to either NL4 speakon or to mains plugs / sockets. We also had breakout boxes similar to yours but we didn't use the 16amp Ceeform, just the standard NZ "crowsfoot" 10amp outlet for connecting to individual lights. There was some Ceeform stuff, but the main 32 amp three phase connectors were the New Zealand made PDL-56 series, which are very waterproof, as they have a screw ring and gasket. And they needed to be at some of the shows & raves we did. When the three-phase got up to the next level of distro, 63 amp Ceeform connectors were common. Any more current than this and it was usually individual cables with Cam-Lock connectors.
@doctorcraptonicus7941
@doctorcraptonicus7941 5 лет назад
"Entertainment industry connectors" or "agents" as we call them.
@Snolferd
@Snolferd 5 лет назад
Dude I love these kind of job videos explaining specific things.
@superscatboy
@superscatboy 5 лет назад
Never thought I'd ever feel nostalgic about lighting rigs. Trust the big guy to prove me wrong.
@avejst
@avejst 5 лет назад
Thanks for showing the equipment, nice to hear the history as well 👍 Thanks for sharing 😀👍
@braeburnhilliard8340
@braeburnhilliard8340 5 лет назад
Those are some pretty interesting connectors. The most we work with is the four prong turn and lock connectors for spider boxes and temporary power.
@davidclark3603
@davidclark3603 5 лет назад
Superb video Clive! Please, please, please some more! Thank you!
@julianreverse
@julianreverse 5 лет назад
Single phase CEE is not used in German entertainment industry. Socapex is rarely used, we use Harting Han 16
@julianreverse
@julianreverse 5 лет назад
That's why it's widely called caravan plug :-P
@Anvilshock
@Anvilshock 5 лет назад
Yes, regarding CEE, I've seen it before, but it's rather rare. Socapex comes up not too rarely as multicore connector for as many as 48 pins. Harting tends to be preferred for power applications, rather than signal.
@mrbobbybtv
@mrbobbybtv 5 лет назад
Same in the Netherlands altough some theaters use only CEE
@Gigator
@Gigator 5 лет назад
Some appliances in the big kitchen of the local hostel use the CEE thing or at least something very similar looking.
@JasperJanssen
@JasperJanssen 5 лет назад
DA666 possibly red ones? CEEform is standard in NL and DE for three phase connections, and then it’s red. The blue single-phase 230V type is basically just caravans, and the occasional industrial application, and yellow which is for single phase 110V is something I’ve never actually seen in person.
@RS250Squid
@RS250Squid 5 лет назад
We use Ceeform connectors for our network stacks too, each device has a kettle lead, but they all meet in a box, out of which comes a single ceeform plug into the wall :-).
@Synky
@Synky 5 лет назад
Never did I think I'd be so interested in power cables to the point I watch a 9min video on them... Dear lord
@SpaceMountainLarry
@SpaceMountainLarry 5 лет назад
Here in the US, I rarely see CeeForm connectors used for power, though it is still used to a degree. In the US, I mostly see Cam-Lok connectors used for big items (such as 24KW "Daylight" fresnels) and for lower current items, I see Hubbell Twist Lock used
@NeneExists
@NeneExists 5 лет назад
SpaceMountainLarry we use powerlok in the UK, because they're harder to shove fingers inside of
@alexanderbrust2989
@alexanderbrust2989 5 лет назад
I love Neutrik connectors.
@quadsofthestoneage9333
@quadsofthestoneage9333 5 лет назад
With the right amount of lube they are all good.
@CJDavies
@CJDavies 5 лет назад
STX series Neutrik speakON are a whole different level, it's insane.
@rarelycomments
@rarelycomments 5 лет назад
Agreed, the plastic ones are a bit crap but the metal STX ones are great. Quite waterproof as well.
@BRUXXUS
@BRUXXUS 5 лет назад
Never not satisfying!
@josephbarrett2425
@josephbarrett2425 5 лет назад
I work in a Grip and Electric rental house and our Neutriks fucking come back broken all the time. They still work technically but the locking slide comes off easily then the small spring is often lost.
@ColinTimmins
@ColinTimmins 5 лет назад
Love the bagpipes in the background. Thanks for the video updates while you're working. =]
@neodos
@neodos 5 лет назад
Very interesting, thanks for sharing, plus those connectors look super cool.
@mimikyoo
@mimikyoo 5 лет назад
I don't know what I love more. this guys voice or the bagpipes in the background
@soranuareane
@soranuareane 5 лет назад
I absolutely loved those bagpipes in the beginning. Need more bagpipes.
@chilledoutpaul
@chilledoutpaul 5 лет назад
very interesting Clive, i love the snippets of your work life!
@rarelycomments
@rarelycomments 5 лет назад
Thought I'd know all of this already but clicked through anyway - never seen that square four pin thing in my life! Thanks Clive!
@thavinator
@thavinator 5 лет назад
Apparently D54 was almost exclusive to the UK, but it looks somewhat similar to LMX/MPX which was mostly (AFAIK) used on small point-of-load dimmer packs, but with different voltage levels. Here in the US prior to DMX we had AMX192, which was a similar serial/analog scheme that used an interesting combo of an analog voltage level signal with an RS485 clock on a 4-pin XLR.
@jd_27
@jd_27 5 лет назад
Love the background music! You're an awesome chap.
@feelthefears
@feelthefears 5 лет назад
As a vfx supp I always wanted to know how they connect stuff on set. Thanks for this one. Also, nice to know a bit about your real work.
@soundguydon
@soundguydon 5 лет назад
Aaaah I miss my theatre days ;-) I was an audio engineer (just a sound-guy) ;-)
@soundguydon
@soundguydon 5 лет назад
Yep - back in my college days I was M.E. for a couple shows, but my passion always was (and is) audio. I haven't done theatre in years, but I love it when you're at work and talking about current industry things, as I've been out of the loop for a bit too long at this point. ;-) Love your channel Clive :-D
@johnbouttell5827
@johnbouttell5827 5 лет назад
A great insight into the world of chunky-robust
@abecoulter18
@abecoulter18 5 лет назад
I have just purchased 4 of those soccapex to 16amp cee truss distribution boxes. Brilliant. Saves on cable runs. Indoor events only
@Bottswana055
@Bottswana055 5 лет назад
Calling in from another part of the entertainment industry/live events. Hopefully will bump into you one day on site. Thanks for the entertaining videos
@AC9BXEric
@AC9BXEric 5 лет назад
Sadly here in the USofA many manufacturers of DMX gear are using 3 pin XLRs. Apparently this is supposed to be for convenience, grab any cable with XLR and it works for audio or lighting. Or perhaps because 3 pins are cheaper than 5. But of course this muddles things up for some users. It's certainly easier to identify cables depending on the connector.
@AC9BXEric
@AC9BXEric 5 лет назад
@KeeDx3 I hear you.
@Mrboomal
@Mrboomal 5 лет назад
It's not really a Chinese thing. HighEnd, Martin, Robe all used 3 pin.
@CHGOfficial512
@CHGOfficial512 7 месяцев назад
Didn't know you had videos with the topics of event (and entertainment) industry, that's great.
@nutsnproud6932
@nutsnproud6932 5 лет назад
That was really interesting Clive. Thanks.
@DiyEcoProjects
@DiyEcoProjects 5 лет назад
Dear Clive, Im enjoying the tour of yer job, interesting stuff. Hope youre keeping well, all the best kieron
@sanderhollestelle5801
@sanderhollestelle5801 5 лет назад
I like the bagpipe music, in the back ;)
@elitearbor
@elitearbor 5 лет назад
I love little control boxes like that. I have a multitude in my shop, having been made over the years for various purposes... they have a certain something that most commercial offerings lack.
@justalilbitnerdy
@justalilbitnerdy 5 лет назад
I was already familiar with XLR, that's it... thanks for teaching me :)
@cowboyfrankspersonalvideos8869
Back in the mid 1970s, I had to relocate a hard wired analogue dimmer control panel to install it into a 20 foot console we built. This was in the days before digital control circuitry. At that time, the US electrical code required we use 12 gauge wiring, even though the panel only used 24 volts. I think there were about 100 wires involved. We had to buy 6 inch greenfield flexible conduit to hold them all.
@johnfrancisdoe1563
@johnfrancisdoe1563 5 лет назад
Cowboy Frank's Personal Videos Copper gauge is determined by current, not voltage. Voltage determines the gauge of the isolation plastic/rubber.
@cowboyfrankspersonalvideos8869
I am aware of that. I should have been more specific. The only current feed component on the dimmer board were small 1000 ohm variable coil wound liner resistors. The issue was the code hadn't caught up with the technology of that time. In this case the amperage running through those 12 gauge wires was only about 200 ma which fed the electronics (tracs and control circuitry) in the dimmer panel back stage. At that time, electronic dimmers had only been around a few years. Just 7 years earlier, my high school which was brand new was still using variable transformers.
@dcaonoek
@dcaonoek 5 лет назад
It makes so much sense to find out you work for PRG. I worked for a major live audio provider in Aus. What you call a Harting in Australia is usually called a Weiland and is mostly only used for chain motors. I started an electrical apprenticeship here in Aus and asked the electricians if they had heard of CeeForm or powercon and they looked at me as if was taking jibberish. The beautiful thing about powercon is that it's good for 20A at 240v and it's the same size as a 10A IEC. I sometimes miss working on gigs but I don't miss hauling 100m of powerlock though.
@unmanaged
@unmanaged 5 лет назад
Sock connectors! I work part time as a stage hand with 3 theaters one is broadway and the other two are smaller and an old school auditorium in Nashville Tennessee nice to see you show the world these things
@zx8401ztv
@zx8401ztv 5 лет назад
I like the multipin connector on the side of the connector box, reminds me of the military connectors i used to solder wires to, in a factory :-). Locating notch and ring, really nice design, reliable.
@sniffy6999999
@sniffy6999999 5 лет назад
Up at the Edinburgh Festival again. Now that's a great job.
@GigglyWolf90
@GigglyWolf90 5 лет назад
I worked in the industry I personally love that your teaching about this. I even did an Adelle and Ozzy concert on Ozzy I was basically his personal Butler lol awesome job
@helyeah2016
@helyeah2016 5 лет назад
Wow I’ve been following your channel for so long now and never realized you worked in the same industry. Really cool stuff. Definitely a bigger fan of the True1 connector over power con especially since the connectors can now plug into each other if you need to extend further. Not sure if you’ve heard about the new connectors being used on tour that still have the 6 circuits but also carry data in the center few pins and the best part is it’s quarter turn collar lock so no more gummed up threads and wiggle-turn-wiggle-turn of Socapex
@falloutpictures
@falloutpictures 5 лет назад
I've given myself a good shock on the stage connector pins a few years ago while replacing a 2k Fresnel fixture. Not long after the lamp exploded... Why did I ever leave the TV/ Theater business?
@ScottHolland0331
@ScottHolland0331 5 лет назад
Great information. I'd be interested in more coverage of the equipment and tech behind the scenes in the entertainment industry.
@theteenageengineer
@theteenageengineer 3 года назад
😂 the socapex brings back some memories for me, it looks a lot like a stage pin multi cable, up until last year the small high school black box theater I’ve been working in had used stage pin as the main lighting power connectors, so we had 2 stage pin multi cable panels on each side of the stage, each with 8 connections, then a multi cable would run to a certain spot in the grid, and it would connect to a fanout that had 8 stage pin connectors on it to connect lights too, it’s an older ETC system, and all the dimmers were in a cabinet back stage where we had 48 dimmers each controlling 2 channels which gave us a total of 96 750watt halogen channels. Those multi cables were a pain in the butt, they were about and inch thick, and they weighed a ton. Now we’ve completely converted to LED pars and spots, that use powerCon for power and DMX for data transmission.
@ua89das7ufj
@ua89das7ufj 5 лет назад
those ceeform connectors are also often used on caravan trailers for feeding power in, at least over here
@NOWThatsRichy
@NOWThatsRichy 5 лет назад
Intresting seeing the different uses for some familiar connections, the 16 amp blue 'commando' plug is pretty standard (caravan sites) also used in industry, we used them in my last job, (plastic injection moulding factory) for connecting auxiliary equipment to moulding machines, also used the 4 pin Harting plugs and the rectangular version of the 19 pin plug for connecting hot runner heating controllers to mould tools and for data interconnections for pick & place robots. Also used the red 32amp 3 phase commando type plugs on 9Kw mould tool water heaters.
@antronk
@antronk 5 лет назад
I really enjoy these videos backstage (literally) ^^
@dave1812
@dave1812 5 лет назад
the 4 pin Harting is just called HAN4. A colleague almost got electrocuted when she picked one up from the ground, and the insulation on the cable was broken so the Metalcasing was live at 230V
@Whatsinanameanyway13
@Whatsinanameanyway13 5 лет назад
Interesting to see you working in the entertainment industry. I was recently introduced to your channel by AVE, and have watched a bunch of videos but never made the connection. I have been in the industry in the US for the last 15 or so years, although I'm more an office rat these days doing design & engineering. In the US we see Socapex quite a bit, along with Powercon being common more recently, but twist lock connectors (NEMA L5-20,L6-20,L14-30,L21-30 being common at least in our inventory) as well as 20A stage pin for dimmed circuits. For high amperage (feeder) in the US it is almost exclusively Cam-Lock 400A single conductor connectors from what I've seen.
@NINcorp
@NINcorp 5 лет назад
Had no idea you were in the entertainment industry. Shout out to a fellow tech!
@jrsc01.
@jrsc01. 5 лет назад
It would be nice for someone to film you whilst making a video so we see some behind the making off a video. And the shenanigans that go with it!
@tbelding
@tbelding 5 лет назад
My seven years in theatre was primarily indoors, but we always used three prong twist lock connectors. Fast to swap, impossible to get in the wrong direction, and you can just about swing from them before they release. Edit - I've used a lot of XLR cables as well. Mostly audio, including connecting an ANCIENT stereo microphone - one of the ones that looks like a huge hammer head from the 50's. (still have it).
@isettech
@isettech 5 лет назад
When you get into multi universe DMX, I am surprised you didn't cover DMX over Ethernet and the Cat 5 jacks and plugs inside XLR shells called ethercon connectors. Of the two most popular standards Artnet and E1.31 or streaming ACN, I prefer streaming ACN. It can use traditional network switches for low cost and high reliability distribution. Many lighting desks have either Artnet or E1.31 built in for multi universe shows. An example is the Leviton Piccolo series consoles supporting Artnet on Ethernet. With more DMX and intelligent fixtures with the transition to LED over incandescent fixtures, the scoapex connector is falling from use very rapidly. DMX over Ethernet to each truss is becoming more common as reconfigurations are very simple. Plug in power and network connection and the install is done except setting the universe and channels used by the fixtures on the bar.. Have you started using DMX over networking yet? With a small number of universes, a laptop and a wireless router makes for a great traveling show setup. Router is on stage and the laptop now only requires a power connection to run a show cue list of scenes. I typically for a small show run between 1 and 3 universes over ACN streaming E1.31 ethernet. For larger shows where wireless network connections may be an issue, and more universes need supported, a Shielded CAT 5 cable is used for the link. If you know where to look, there is some very affordable ACN and ArtNet gear available. Some software is low cost or free. For one universe of ArtNet Freestyler is dated but works well. For multi universe Streaming ACN, QlightsPlus works very well for many show applications. Both of these programs are free. There are more complex and commercial offerings such as Madrix and some by major lighting manufactures.
@TUISK0
@TUISK0 5 лет назад
In Estonia in stage industry we are using: shuco, 16A 3phase CEE, 32 3phase CEE, 63A 3phase CEE, 125A 3phase CEE, power lock for 400A and for bigger loads cable luggs and big cables :D . For multi core we are using socapex, it is also used for direct control hoists.
@steverpcb
@steverpcb 4 года назад
I remember some years ago running a multicolor 10v cable down a pipe to the desk, the shell had to be removed and then it would drop down it with no problem :) I came in one day during the install to find that for some reason the boss had cut the whole plug assembly off due to not being able to get it back up the pipe for some reason. It cost him a full plug assembly as the pins were crimped and not re usable, all he had to do was to take the shell off !
@Rhys_Official
@Rhys_Official 4 года назад
PRG Event Hire. Spoke to them a while ago, nice people. I work within the event industry so I see their flight cases quite often.
@EdFortune
@EdFortune 5 лет назад
Big Clive, well connected in the entertainment industry
@phonotical
@phonotical 5 лет назад
I love how comfortable you are recording a video with people in the room watching you, most people are like, holy shit other people! And then run away and get all shy, like how people stop talking to eachother when you walk past them
@raineylights
@raineylights 7 месяцев назад
Where I've worked with fairgrounds, I've seen the 4 pin connectors used for 2 channel lighting on certain rides
@guitarstitch
@guitarstitch 5 лет назад
Those look substantially more convenient than what I work with in the hobbyist realm. ;)
@TomStorey96
@TomStorey96 5 лет назад
The great thing about standards is there are so many to choose from!
@Dust599
@Dust599 5 лет назад
yay bagpipes in the background.... (seriously, I really miss them!)
@johnjoyce
@johnjoyce 5 лет назад
Finally a break from orange lunatics, Star Wars, and weird science..
@thomasstrickland0
@thomasstrickland0 5 лет назад
Ah yes. This is how I learned how to solder. I’ve made many speakon, trs, xlr, neutrix and every other connector you could think of way back in the day. I used to work for a company called Quality Sound and Video. Also used to setup for many large concerts.
@phils4634
@phils4634 5 лет назад
Quality Sound and Video used to be a major player in the Outside Broadcast and Location Film industry. Your bunch did the sound for a location filmed at St Bartholomew the Great church in London - and they were parked right outside the lab where I worked at that time (North East Thames Radioimmunoassay Laboratory - better known as NETRIA)! I think the vans were painted maroon (though I'm not so certain of that!)
@loberd09
@loberd09 5 лет назад
You need to get your coworkers on more. They are hilarious.
@Tularis
@Tularis 5 лет назад
This was really interesting!
@HiSmartAlarms
@HiSmartAlarms 5 лет назад
Make more videos at your work please!
@Croz89
@Croz89 5 лет назад
Some of the welding equipment I had at work used Amphenol MIL spec connectors, they looked a lot like Socapex but I think they are slightly different.
@moistmoustache420
@moistmoustache420 5 лет назад
cool prg, i had no idea you were in the industry :) big props
@remyrattner6399
@remyrattner6399 5 лет назад
In the US, we use stage pin as a means to connect lights to the mult bundles.
@phiwatec2576
@phiwatec2576 5 лет назад
I like these kinds of videos :) If possible make more.
@cue1gonow
@cue1gonow 5 лет назад
The Harting Han connectors also go by the name "washdown connector" (due to their gasketed construction) here in North America , when you're buying them from other suspects like McMaster-Carr or Automation Direct. Love seeing a fellow lampie share our world!
@Arachnoid_of_the_underverse
@Arachnoid_of_the_underverse 5 лет назад
SE Lock and Key Very interesting Clive thanks .It would be nice if possible, to see some of the lighting arrays wired up on the overhead framework
@ChloeStandingUpstairs
@ChloeStandingUpstairs 5 лет назад
we call harting connectors wieland connectors in australia, although i've never seen a 4 pin one, mostly just 16 pins and up
@Yfr28
@Yfr28 5 лет назад
I used to work at a laundry, we had the four pin philips lighting connectors on irons that had a steam table with them
@rustyshackelford9612
@rustyshackelford9612 5 лет назад
Pretty awesome you work for PRG, hope to see you in a shed stateside
@felenov
@felenov 5 лет назад
We use the three pin connectors in Russia as receptacles for high energy single phase loads. We use the powerconn in end server and networking gear
@tommihommi1
@tommihommi1 5 лет назад
that blue connector you call ceeform is used on basically all camping grounds and caravans, I had no Idea they were used by the entertainment industry too. Makes sense, though, since you don't have to deal with the annoying different plug types all over Europe that way.
@Mark1024MAK
@Mark1024MAK 5 лет назад
tommihommi1 - The yellow type is very common on worksites where 110V power is used.
@tommihommi1
@tommihommi1 5 лет назад
@@Mark1024MAK not really a thing over here, we use 230V single-phase and 400V three-phase pretty much exclusively.
@Mark1024MAK
@Mark1024MAK 5 лет назад
tommihommi1 - I was referring to the usage in the U.K. That is on construction and building sites, temporary engineering worksites and other temporary supply systems (e.g. temporary site / utility / public lighting). The 110V is supplied via 240V to 110V isolation transformers. And the secondary supplying the 110 is centre tapped to earth (ground). So the maximum voltage between earth/ground and either conductor is 55V AC. If there's a power tool available in the U.K., there will be a version rated at 110V and supplied with a yellow CEEform plug... (including radios to keep the workers happy :-) ).
@tommihommi1
@tommihommi1 5 лет назад
@@Mark1024MAK that seems like a whole lot of effort for very little gain. Everyone else in europe just uses the standard stuff everywhere. Especially since you're gonna want beefy devices with lots of powah on building sites, so the higher voltage and option for 400V three phase for the big guns kinda helps a lot.
@robinturner2300
@robinturner2300 5 лет назад
Mark 1024MAK Spot on mate...the three types are similar but not actually interchangeable. Intentionally so for safety reasons and to keep Red 3 phase, Blue 240 v and Yellow 110v from being connected. The UK safety people won't allow mains tools on a building site which aren't 110v, lots of builders like battery tools for this reason. There is no way 3 phase would be allowed in what is often a wet environment as its lethal.
@mavos1211
@mavos1211 5 лет назад
We used to use a similar plug in the refrigeration industry but it was called a martin lunel plug.
@Culturedropout
@Culturedropout 5 лет назад
The "Socapex" reminds me of some of the Amphenol connectors we use in the environmental monitoring industry. There are many, many different configurations that can be done with the same connector shell. The military is also very fond of them.
@Savagetechie
@Savagetechie 5 лет назад
They are a mil-spec connector. You can get a soca with a nato part number and it will only cost you 3 times as much.
@TheSchnabsiX
@TheSchnabsiX 5 лет назад
The Harting is a HAN 3A-STI. Very common in automotive. In automotive you have either Harting or round connectors (M8, M12, etc)
@JasperJanssen
@JasperJanssen 5 лет назад
We used to have those giant rectangular connectors instead of the round multiocnnectors, back in our school’s gym. They’d hold 8 circuits, with 2x8 pins, and we’d have fanouts with flexes going to schuko, rather than ceeform, us being a Schuko country.
@unpronouncable2442
@unpronouncable2442 5 лет назад
4:34 Haha I see what you did there. you are talking about power and said "it is worth keeping an ion"
@71dembonesTV
@71dembonesTV 5 лет назад
I'd be willing to bet Big Clive has made lots of important *connections* in the entertainment industry.
@antonykahil
@antonykahil 5 лет назад
In North America we tend to use twist lock instead of Cee form (we call it pin and sleeve) we have 15/20 amp versions for both 120v and 240v. TRue1 seems to be becoming a standard here.
@chasmosaurus3
@chasmosaurus3 5 лет назад
In data centers, we used twist lock up to 30A. After that, is was typically pin and sleeve or CS because there isn't a NEMA standard twist locked rated at 40A and 50A (last time I checked). NEC prefers you to hardwire I guess. That's not practical in a data center though.
@tbelding
@tbelding 5 лет назад
Oddly enough, the True1 seems to be a solution looking for a problem. There are NEMA configuration 50 amp twist-lock plugs. They aren't specifically NEMA, but they use the exact same configuration - and since Hubbell invented the plugs, they can darn well determine the 50 amp plug and receptacle :) (They list them as "NEMA configuration", using the L16-30 designation)
@nickwallette6201
@nickwallette6201 5 лет назад
IT style twistlock (Hubbel) plugs are so flimsy feeling. I hate those things. I'm not sure how often they develop loose connections, but it seems like it ought to be a common problem - at least if they are subjected to more than a few mating cycles. I use SpeakOn connectors when I moonlight as a sound guy - they're fantastic. I would love to see PowerCon connectors replace NEMA twist-locks.
Далее
Entertainment industry 400A powersafe connectors.
14:20
Gale Now VS Then Edit🥵 #brawlstars #shorts
00:15
Просмотров 376 тыс.
My favourite industrial connector (Ceeform).
16:14
Просмотров 227 тыс.
Clone of Wago product that Wago don't even sell???
11:07
Meet The Gaffer #52: Power Distro for a Sitcom Stage
13:24
Inside a Wago connector and a clone
11:50
Просмотров 139 тыс.
Lighting 101 Series - Part 5: Basic Rigging
4:26
Просмотров 104 тыс.
Fans; High is next to Off on purpose
17:48
Просмотров 4,2 млн
Perhaps the weakest link in the US electrical system
25:48
Lighting Cables 101! PCON, SOCA, TRUE 1??
5:18
Просмотров 10 тыс.
PRO AUDIO EP. 3 | EVENT POWER | 3 PHASE & SOCAPEX
14:25
A Quick Connection System for Power Tools
10:39
Просмотров 290 тыс.
Gizli Apple Watch Özelliği😱
0:14
Просмотров 4,1 млн
Развод с OZON - ноутбук за 2875₽
17:48