In this video I visit a lady that had a huge electric bill, and quickly narrowed it down! #hvacguy #hvaclife #hvac #airconditioning #electrician #heatingandcooling #hvactrainingvideos #hvactroubleshooting #hvaccompany #electrical #hvactechnician #skilledtrades #bluecollar #bluecollarpride #heatpump #heatstrips #airconditioner #furnace #minisplit #aireacondicionado
Merch Store : hvac-guy-2.cre...
Here are links to the tools I use, And it costs you nothing extra to buy from this list:
Makita Wet/Dry Vac: amzn.to/3VVHpsz
Veto OT-LC: amzn.to/3wSK1Nj
Appion AV760: amzn.to/3OkrwHC
Fielpiece SC680 Clamp Meter: amzn.to/33rhxvE
Fieldpiece SC480 Clamp Meter: amzn.to/33kfgCB
Fieldpiece SMAN 480 Digital Manifold: amzn.to/3twfVvA
Fieldpiece DR58 Leak Detector: amzn.to/3nt1TXw
Fieldpiece JL3KM2 Bluetooth Manometer set: amzn.to/3blMrJR
Fieldpiece Bluetooth Scale: amzn.to/3Gzveab
Fieldpiece SDMN6 Manometer: amzn.to/3qwk9RP
Yellow Jacket Tubing Expander: amzn.to/3sjuK3a
Milwaukee M12 Impact Driver: amzn.to/37xXkqk
DIY Vacuum Attachment for drains: amzn.to/3tDpfNU
Fieldpiece Smart Probe Kit : amzn.to/34NG3HL
Klein Heavy Duty Wire Strippers : amzn.to/3I8YNzT
Klein Needle Nose Crimpers/Stippers: amzn.to/3fuwXlw
Klein Knee Pad: amzn.to/3cy6FB0
Klein 7in1 Flip Socket: amzn.to/3bpabwG
Klein Journeyman Pliers: amzn.to/3tvB60w
Milwaukee Slim Packout On My Torch: amzn.to/3KeLm3j
Aluminum Packout Wall Mount on torches : amzn.to/3Kf9hQg
Milwaukee Tool Box: amzn.to/322iyK9
Veto Pro Pac Tech MCT: amzn.to/3nwwQdA
Milwaukee Hook Blade Knife: amzn.to/33F3m5T
Testo 300 flue gas analyzer: amzn.to/3IcS3Bd
Western Nitrogen Regulator: amzn.to/3rmdKrx
Klein Canvas Bucket: amzn.to/3FyzKVf
Flag Velcro Patch Kit: amzn.to/3K8Eswx
Supco Magnetic Door Switch Holder: amzn.to/34IcXcL
Milwaukee Magnetic Light: amzn.to/3FulCfF
Milwaukee Rechargeable Headlamp: amzn.to/3nuXsvf
SS2 Float Switch: amzn.to/3K7LJMW
3-Amp Breaker: amzn.to/3nxaSXJ
Appion Valve Core Removal Tool: amzn.to/33CFArw
Appion G5 Twin Recovery Machine: amzn.to/33Dvd6C
Yellow Jacket Large Tubing Bender: amzn.to/3qwJv1U
Similar Small Tubing Bender: amzn.to/3fJsziJ
Fluke Twist Guard Test Leads: amzn.to/3216R6j
Honeywell T-4, 2-Heat, 1-Cool Programmable Thermostat: amzn.to/3qtIuaX
Kidde Carbon Monoxide Alarm: amzn.to/3qtIIyP
SolderWeld Flame Resistant Magnetic Blanket: amzn.to/3qtJ4Wb
Malco 1/4 - 5/16 flip bit : amzn.to/3nr67yU
Quick Check Acid Test: amzn.to/3GA2XAy
Wiha Torqe Screwdriver : amzn.to/3u1swH6
Wiha Torqe Screwdriver 1/4” adapter: amzn.to/3IH22Pw
Compressor Tote: amzn.to/3H8xHst
Inspection Mirror: amzn.to/3r9PERV
Wiha TorqueVario-S 10-50 in/lb Torque Screwdriver : amzn.to/3GbKAku
1/4” adapter for Wiha Torque Screwdriver : amzn.to/3u8g0pq

Опубликовано:

 

28 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 264   
@gilbertjaramillo8735
@gilbertjaramillo8735 Месяц назад
Wow, experience at its best.
@mikepapienuk1040
@mikepapienuk1040 2 месяца назад
He is a smart guy who knows what he is doing. Love watching a pro at work.
@buffalobobbayoushow6040
@buffalobobbayoushow6040 3 месяца назад
Thank goodness!! I hear you brother!!
@rubberman2006
@rubberman2006 3 месяца назад
Couldn’t imagine what their electric bill is with running 3 ac units.
@HVACGUY
@HVACGUY 3 месяца назад
And a pool
@james6794
@james6794 3 месяца назад
well it was $2000 with the heat strips stuck on so its less than $2000
@josefmerritt1849
@josefmerritt1849 3 месяца назад
"That one that looks white that's actually grey is my green" I love that quote. ❤
@BattlestarCanada
@BattlestarCanada 3 месяца назад
That visqueen looked like barrels of fun to navigate😂
@robertlamey7612
@robertlamey7612 Месяц назад
Better than nasty mud usually crawl through
@emoneyblue
@emoneyblue 3 месяца назад
Great job! plus you have the system up and running for your customers and no parts store runs and no down time WIN WIN! WIN
@joebass5163
@joebass5163 Месяц назад
I use the Emporia Vue energy monitor. I can see when loads are high in real time before it's too late and get an electric bill that is sky high.
@bills6946
@bills6946 3 месяца назад
Always install the screw first. Remove it and screw the relay on. He is lucky he didn’t need stitches when that relay spun….twice!
@robertlamey7612
@robertlamey7612 Месяц назад
Some people aren’t sissies and run for stitches. Electrical tape and get back to work
@Mike-xe4fk
@Mike-xe4fk 3 месяца назад
Air Handler/Electric Furnace Diagnosis, Bravo. Break it down to the 'elements' (lol) . I once had a no-colling call, found a Normally Open Heat Relay that was closed with no 24 V command, during AC cycle. Replaced it, problem solved. Same deal here, pretty much
@sadsamr-un8rl
@sadsamr-un8rl 3 месяца назад
A wonderful achievement. Thank you for your effort. I have a question. Please, can I replace a reciprocating compressor instead of a Koblin rotary compressor and convert it to a Suncle Phase?
@HVACGUY
@HVACGUY 3 месяца назад
Lot of questions
@joehrlein847
@joehrlein847 2 месяца назад
Nice job Curtis. Have a great 4th!
@joecummings1260
@joecummings1260 Месяц назад
I never have this problem. When I light my coal fired boilers, I shut off the breakers for the AC lol. When summer comes, I shut the coal feed off, the fire goes out, and I turn on the AC breakers. Old school is the best
@larryehrlich57
@larryehrlich57 3 месяца назад
My 19 year old son and I keep our house at 80° in Florida...in the summertime. We are both active out doors and we are climatetized and comfortable at 80°. When we go to other people's homes...we always bring something warm to wear...otherwise we freeze!!!
@victorgalagan1151
@victorgalagan1151 3 месяца назад
Genius.
@rafaelandreano
@rafaelandreano Месяц назад
This maybe a dumb question but how does the relay know when to bring it on/off the electric heats? I need to go back to the drawing board. And also what’s the blue wire that he set it on the N/C for?
@Jcicaroni82
@Jcicaroni82 2 месяца назад
The good old fire board, they're lucky. Usually that takes out a bunch of wires and everything.
@scoobtoober2975
@scoobtoober2975 3 месяца назад
A friend mentioned their ac runs all the time. They mean non-stop. Please don't ignore it. I try to encourage everyone to take a small part in their car and home. To give it a once over. That bill would kill me.
@bobbycammon6694
@bobbycammon6694 Месяц назад
My unit blows cool air all day and won't shut off. I go the mode on auto and fan on auto. Do I need to change my filter and it will shut off once the room gets cool?
@bobboscarato1313
@bobboscarato1313 3 месяца назад
You should detect a stuck strip due to bad relay or sequencer by the smell of dust on the element.-
@jaysonbowe2747
@jaysonbowe2747 2 месяца назад
Do you have the wiring diagram.... Those under home air handlers are so hard to work on good job and better explanation..... I would have been swearing a few times.
@andreakeeling9217
@andreakeeling9217 Месяц назад
3 AC units on a single family home?😮
@ramonpardo9550
@ramonpardo9550 3 месяца назад
yep,we all breathe like that down there.
@UQRXD
@UQRXD 2 месяца назад
That thing looks nasty with mold.
@Cragified
@Cragified 2 месяца назад
infuriates me every time to see duct tape used to secure vapor barrier... because it does what duct tape always does eventually ages gets brittle and lets go like you can see when he first enters the crawlspace. Leaving a gap for water vapor to enter the crawlspace.
@Jon-hx7pe
@Jon-hx7pe 3 месяца назад
it's crazy how a homeowner wouldn't notice this problem until electric bill comes - system running far longer and air at vents not cool. should be so obvious - shut it down and call for service!
@jenko701
@jenko701 3 месяца назад
As bad as hate masks ,I have to make myself use them under houses .
@dfirth224
@dfirth224 3 месяца назад
And in attics
@jamierushing
@jamierushing 3 месяца назад
Hi bro
@HVACGUY
@HVACGUY 3 месяца назад
What's up?
@jamierushing
@jamierushing 3 месяца назад
@@HVACGUY it is so hot
@ThomasPerez-l1p
@ThomasPerez-l1p 25 дней назад
Brown Kevin Martin Timothy Rodriguez Angela
@user-sp1mi6dt7i
@user-sp1mi6dt7i 22 дня назад
Walker Jose Johnson Shirley Williams Cynthia
@WayneBonham-t9b
@WayneBonham-t9b 20 дней назад
White John Harris Steven Allen Kimberly
@CurtisDahl
@CurtisDahl Месяц назад
Jones Jessica Miller Deborah Allen Michael
@SX939
@SX939 3 месяца назад
Who the hall approved the system modification. It is now bastardized from factory design.
@amiatroll6347
@amiatroll6347 3 месяца назад
Lotta good that factory design did
@markbeiser
@markbeiser 3 месяца назад
Nobody cares!🤷‍♂
@darrolreeder235
@darrolreeder235 3 месяца назад
You are a true HVAC TECHNICIAN, not a salesman in technicians uniform. Keep doing what you're doing.
@TheVaga9
@TheVaga9 3 месяца назад
How the hell can he remember all those wires and so many different systems??? This guy could be a brain surgeon, Blessings!!! He just reengineered a system on the fly!!!
@str8chevys913
@str8chevys913 3 месяца назад
He is one smart dude. Heck I couldn't do what he does, I walk to a room to go get something and soon as I get there, I say to myself what did I come in for.
@whosyourdady909
@whosyourdady909 3 месяца назад
My neighbor was a home alarm installer and I had him hook up my alarm keypad. There’s about 10 different colored wires. He asked me what color one of the wires were he was colorblind
@andylaw2503
@andylaw2503 3 месяца назад
@@whosyourdady909 Thank you for making me laugh on a Friday night~LOL
@whochecksthis
@whochecksthis 3 месяца назад
Hvac wiring isn’t terribly difficult. What will REALLY get you is the communicating systems with condenser wiring controlling the air handler… man the York heat pumps are the worst! 10 colors, hat have to be wired one way at the stat, one way at the condenser, then a completely different way at the air handler… multistage, multi speed system… with outdoor thermostats as well… One unit has like 30 different connections…
@whochecksthis
@whochecksthis 3 месяца назад
@@str8chevys913yeah, wiring in a strip kit with blower control when it was controlled by the board is fun. Man, remember working on the old ge cubes with timer controlling tpdt high voltage relay… so much fun…
@hinspect
@hinspect 3 месяца назад
I like getting rid of PCB that handles high current. Great job!😊
@HVACGUY
@HVACGUY 3 месяца назад
Thanks
@kg4muc
@kg4muc 3 месяца назад
A $ 200 power bill would be about normal here😮 Definitely wouldn’t take long to run it up with a stuck on heat strip. Good fix as usual! Stay cool and have a good weekend. Looks to be a hot one
@maxwellmelon69
@maxwellmelon69 3 месяца назад
Well assuming just a low end 5kw heater…thats 96kwh a day…30 days that 2880kwh a month…..and thats not including the fact the other units are fighting this unit heating the air….a normal home only uses 1000-1500 a month.
@dregenius
@dregenius 2 месяца назад
​@@maxwellmelon69This is why "heat strips" should not be a part of modern civilization... we have *SO MANY* much better methods of heating a space than just a "build it cheap and let the tenant pay" boomer-tech resistive heating...
@floydestelle6242
@floydestelle6242 Месяц назад
2,000 dollars
@TheTardis157
@TheTardis157 Месяц назад
@@dregenius Heat pumps are the future! It's just an AC unit with a reversing valve and a stronger evaporator. Really not much more expensive to make. But the companies want you to believe they are!
@Gio-X-Man
@Gio-X-Man Месяц назад
$2000 Bill
@kellymeade4587
@kellymeade4587 3 месяца назад
The very same thing happened to a unit at my home Last month. We Had an $880 insane power bill… I couldn’t believe it. I’ve worked on control systems for the aerospace defense industry, in R&D development… for over 23 years. I also found the melted relay, causing My heat strip to be stuck on…pulling Current, while the AC was running. I bypassed the control board just like you did. Great video!
@Rico-oy3dc
@Rico-oy3dc 2 месяца назад
Sequence switches seem more fragile than others...
@gregorysuarez7978
@gregorysuarez7978 3 месяца назад
Should have used a contactor for the strip heater. Relays are typically rated >15amps. Replacing the board would require an additional trip since that would not be a typical truck inventory part.
@robertlamey7612
@robertlamey7612 Месяц назад
Always best to use the factory parts
@OnusBones
@OnusBones 3 месяца назад
Silly question: why use the board in the first place, if the relay handles the job? Looks like more over-engineering so someone can make parts money down the road.
@pstiegman
@pstiegman 3 месяца назад
The board was a fan speed sequencer in addition to controlling the heat strips
@dfirth224
@dfirth224 3 месяца назад
BINGO!! The manufacturer wants you to think you are getting a lot for your money. Also the boards are cheaper to install at the factory.
@pstiegman
@pstiegman 3 месяца назад
Fan sequencing has good and valid applications. Low for dehumidification. High for an extra boost of heat in Winter.
@rickdiego5
@rickdiego5 3 месяца назад
Just thought I'd let you know that I watch a lot of videos and all of yours and you do a great job videoing your content so that we can see what we want to see and need to see. Your effort is appreciated.
@HVACGUY
@HVACGUY 3 месяца назад
Thanks
@dislodgegarage9849
@dislodgegarage9849 Месяц назад
The next guy is gonna be like "WTF?"
@BlueMonte-v8k
@BlueMonte-v8k 2 месяца назад
He handled the call with extreme precision. His diagnosing skills are grade A. Your a certified boss out here. Job well done bro. Love the videos keep going!!! I'm learning a ton thank you so much..
@LVCMS
@LVCMS Месяц назад
Agreed excellent job
@grandinosour
@grandinosour 3 месяца назад
I never could understand why a PCB is used in a simple air handler like that when just relays and contactors will work just the same....Just remember to wire a bypass link to provide fan power from the first contactor or sequencer in case the fan relay fails. This forces the fan forces the fan to run when the heat strips are powered on.
@joemartinez-673
@joemartinez-673 3 месяца назад
Would you send me wiring diagram of what you just said ? Thanks
@williamjones4483
@williamjones4483 3 месяца назад
Printed circuit board is less expensive than hand wiring point to point. Same with very old school electronics. Hand wired and soldered point to point was time consuming, then circuit boards came along.
@markbeiser
@markbeiser 3 месяца назад
The fan on and off delays get an extra very small bump in SEER rating for the system. Of course whatever energy savings there is over the life of the system is lost x1000 when the board fails!🤣 In those air handlers, the first heat relay already has a provision for powering the fan on, so no need to add one.
@dfirth224
@dfirth224 3 месяца назад
@@williamjones4483 But more reliable. All that matters now is $$$. Who cares if they don't last as long, they are throw away.
@1022hard
@1022hard 3 месяца назад
My suggestion is to wear PPE and talk more about what you see is wrong and how you’re fixing the problem. I could see what you were up to because of my years as a service technician doing what you’re doing. Likely the newbies are not getting the whole picture at times. I am impressed with the way you take on these tough repairs! 👍
@dfirth224
@dfirth224 3 месяца назад
Also wear a mask in attics.
@tomn4838
@tomn4838 3 месяца назад
Gloves do wonders keeping your hands from scrapes, tears and cuts. They do take awhile to get used to and making it a habit to wear.
@jasonsouliere703
@jasonsouliere703 2 месяца назад
PPE - that’d be great to listen to a muffled host explain what he’s doing.
@1022hard
@1022hard 2 месяца назад
@@jasonsouliere703 Ha Ha 🤣
@davidchsw
@davidchsw 2 месяца назад
19 amps looks like too much for that relay.
@renenunez1254
@renenunez1254 3 месяца назад
Curtis...you are the MAN. Really enjoy your videos.
@pilotboba
@pilotboba 3 месяца назад
Their electric bills would be lower if they didn't set the temp to 69deg. That's just crazy talk.
@eddiereichel9354
@eddiereichel9354 3 месяца назад
I bet your the life of the party!
@shannonchambers8860
@shannonchambers8860 3 месяца назад
I keep mine on 68
@Dingleberry1856
@Dingleberry1856 3 месяца назад
The lowest mine will go is 65. I’m looking for an old mercury thermostat that go down to 55.
@derek10w
@derek10w 3 месяца назад
When you have one system to control the master bedroom alone, you live a different life than everyone else 😂
@juliomoreno5370
@juliomoreno5370 3 месяца назад
Is it not higher if it keeps turning on and off ? Serious question
@rjrussell63
@rjrussell63 3 месяца назад
Please wear a mask for gods sake!!!!!!!!!!!!!!!!!!!!!!!!!
@scottchapman9931
@scottchapman9931 3 месяца назад
Mind your own business, for God's sake
@rjrussell63
@rjrussell63 3 месяца назад
@@scottchapman9931 Really!
@Parabellum-X
@Parabellum-X 3 месяца назад
2:57 Curtis, how were you able to clamp your clamp meter around two wires and get an actual reading? 🤔
@HVACGUY
@HVACGUY 3 месяца назад
Those two wires are tied to one leg of power, other side has two black wires tied to it. So, it was like I was clamping onto the main power wire coming in.
@jackkreighbaum783
@jackkreighbaum783 3 месяца назад
In our circs 1958 house, with minimal insulation in the walls, I'm lucky to get the summer (Phoenix, AZ) temps down to 77.
@delltawnnorthri7459
@delltawnnorthri7459 3 месяца назад
Fix that
@harrylumsdon6773
@harrylumsdon6773 3 месяца назад
I got a pallet of insulation 36 bags from home depot, free blower rental. Free delivery, $250.
@shermanmaddoxrcpc774
@shermanmaddoxrcpc774 3 месяца назад
Loved the board elimination. I agree with others why use a board when relays could normally be used for the same function.
@scottchapman9931
@scottchapman9931 3 месяца назад
Because the board is less reliable, which means that the HVAC guy gets returned business.
@shermanmaddoxrcpc774
@shermanmaddoxrcpc774 3 месяца назад
He completely removed the board because what he’d done with the relay eliminated the board. I see no need to return to the unit he worked on unless the relay gives up or some other problem pops up
@mrsmith5114
@mrsmith5114 3 месяца назад
Could that of started a fire? I mean maybe wouldnt spread because in box, but still looked hella dangerous.
@andrewclarke3622
@andrewclarke3622 3 месяца назад
If a heat strip is stuck on, would it remain on regardless if the thermostat being saticfied?
@HVACGUY
@HVACGUY 3 месяца назад
In this case yes
@DubYaJsWorld
@DubYaJsWorld 3 месяца назад
Had this happen twice in the last week! Heat strips running while the ac is on.
@MRosati5000
@MRosati5000 3 месяца назад
Yike's
@bobboscarato1313
@bobboscarato1313 3 месяца назад
It's a pretty common occurence!
@rupe53
@rupe53 3 месяца назад
well, at least the air will be dry, right? (although the expensive way to do it)
@jthonn
@jthonn 3 месяца назад
Keep on trucking. $$$ Three units will make for a high electric bill. Must be a big house.
@GreyRockOne
@GreyRockOne 3 месяца назад
convince me that control board was not needed.. I'm skeptical.
@amiatroll6347
@amiatroll6347 3 месяца назад
Convince me I need to put jet engines on a prop plane for it to fly
@markbeiser
@markbeiser 3 месяца назад
The board only existed to delay the blower on and off to gain a very small bump in the efficiency ratings. The energy savings is so small that it would take a decade or more to cover the difference in cost between replacing the control board and ditching it for a relay. The control board failure already wasted many times more energy than it would have saved in the conceivable life of the equipment. The cooling and heating capacity of the system is unaffected. Whatever dehumidification benefit of delaying the blower on that was lost is more than regained in not delaying the blower off when the system shuts off. The only real drawback is that in heat pump heating mode, the air coming out of the vents will take a little longer to warm up.
@rayofsunshine107h
@rayofsunshine107h 3 месяца назад
Thank you for doing this ...xould help other hvac guys assume its something bigger going on
@fishrman29
@fishrman29 3 месяца назад
Not being a dick here. Why not just replace the board? It is cool though to see you do this though! Awesome job
@pilotboba
@pilotboba 3 месяца назад
Heat strip stuck on. One of my units had that issue.
@jimweinheimer
@jimweinheimer 3 месяца назад
Great service diagnosis. Too bad the A/C system does not have a way to lock out if the heat and A/C runs at the same time
@zekehanscom5869
@zekehanscom5869 Месяц назад
A better question is why do they keep their house so cold, but hey, if they want to pay for the electricity
@robalexander7348
@robalexander7348 3 месяца назад
Well done Curtis, these people must get a Huge electricity bill with this 3 system unit 😮 Au
@pstiegman
@pstiegman 3 месяца назад
Great work Sparky. You make it look easy.
@HVACGUY
@HVACGUY 3 месяца назад
Thanks
@alglen9208
@alglen9208 3 месяца назад
​@@HVACGUYHi Curtis. Your so squared away with your tools. I was just wondering if your a veteran? Love to watch you work and trouble shoot! Have a great weekend and 4th of July!
@steveg8337
@steveg8337 3 месяца назад
How big is their master bedroom 😂
@Fluorescentlighting123
@Fluorescentlighting123 3 месяца назад
Love your videos!! Keep up the good work!!
@HVACGUY
@HVACGUY 3 месяца назад
Thank you! Will do!
@clintonwalker2413
@clintonwalker2413 3 месяца назад
Although Curtis blamed his sneezing/coughing on insulation it could very well have been “harmless” black mold. It’s everywhere on that air handler. Scattered across the panel he removed and on the wiring diagram on the blower housing. I’ve seen it on other HVAC videos as well so Curtis is not alone dealing with it.
@craigbraswell4269
@craigbraswell4269 Месяц назад
I live in W Ga, like Curtis. Let me tell you THAT EVERY air handler unit has a RAINBOW of mold/mildew coloring inside within a hear or 2. Can't stop it, can't fix it, just live with it.
@grudd61
@grudd61 3 месяца назад
Very Impressive skills Curtis! Thanx for sharing.
@carlmccoy662
@carlmccoy662 3 месяца назад
I like the old electric meter bases. I would diagnose that just by looking at it spinning. Try getting a headlamp flashlight for attic and crawl work. They are cheap and work good.
@PosterityOf1776
@PosterityOf1776 3 месяца назад
9340 relay
@craigbraswell4269
@craigbraswell4269 Месяц назад
That's carrier fan timer design ALWAYS melts the relay! What a turd! I've changed HUNDREDS of those and I'm not even a carrier dealer.
@scorpionvice12
@scorpionvice12 28 дней назад
5KCP39CGT447S ANYbody know of a compatible fan motor
@mtbbiker6401
@mtbbiker6401 3 месяца назад
Can anyone recommend wire connectors for compressor wiring instead of using wire nuts?
@hinspect
@hinspect 3 месяца назад
I've seen people use WAGO, but I've never used them. I despise Wire Nuts, too! 😉
@mtbbiker6401
@mtbbiker6401 3 месяца назад
@@hinspect I wonder if I can use a standard bullet style connector or possibly just solder the wires. Would this be better conductor than wire nuts and provide less resistance?
@markbeiser
@markbeiser 3 месяца назад
@@hinspect WAGOs are easier, but properly done wire nut connections can carry more current.
@hinspect
@hinspect 3 месяца назад
​@@markbeiserKerney Clamps are what I always used for high Current, but they look like shit after being taped up with black tape
@dfirth224
@dfirth224 3 месяца назад
@@hinspect I love WAGO. Much better than wire nuts. They were invented in Germany and have been used in Europe for 20+ years with no problems. They are clear so you can visually see the wires inside. Test ports for probe so you don't have to remove any wires.
@RachelJoanna-i6c
@RachelJoanna-i6c Месяц назад
Young Richard Taylor Jennifer Robinson Timothy
@stevencossaboon3237
@stevencossaboon3237 3 месяца назад
Nice job Curtis.
@HVACGUY
@HVACGUY 3 месяца назад
Thanks!
@ranger178
@ranger178 25 дней назад
probably great dehumidifying LOL cool the air then heat it back up again what a plan.
@jonhughes3468
@jonhughes3468 22 дня назад
How do you get a air conditioner under a houses crawl space...never seen this before...
@chrisduhaime5689
@chrisduhaime5689 2 месяца назад
We call it Rheem ing it out
@harrylumsdon6773
@harrylumsdon6773 3 месяца назад
Most smart thermostats would alert you.
@ehsnils
@ehsnils Месяц назад
At 7:33 it did seem like the connector did slide on a bit too easily, but maybe it's good enough.
@h2oman983
@h2oman983 3 месяца назад
I follow you because you bleed knowledge and you are definitely schooling my interest and I see the point on earlier comments regarding saving time and parts costs. But this is the first video where I've seen a (still quality) repair, but wonder out loud if the amount of working backwards & the adapting you did to get the relay you installed to work is better than a replacement OEM board. The next guy (if its not you) may struggle to follow a manufacture schematic on the inside of the panel now that components and wiring aren't the same?
@NEW_INSITE
@NEW_INSITE 2 месяца назад
If a different maintenance technician in the future comes in to work on that and can't figure out what was done then he does not need to be in the business
@h2oman983
@h2oman983 2 месяца назад
@@NEW_INSITEThat's a cold & ignorant response. You ignored the heart of the comment and just showed with your attitude why the trades are so badly looked upon and how the numbers of trades people are in decline.
@derekjackson3990
@derekjackson3990 Месяц назад
If you were going to kill power to the airhandler anyway why not do it before you pulled the wire off that caught fire?
@RustyDodd
@RustyDodd 3 месяца назад
would you rather be under the house or in the attic?
@rayofsunshine107h
@rayofsunshine107h 3 месяца назад
Hummmm i want to know thos answer to...but also how often is it in attic.
@redman1225
@redman1225 3 месяца назад
I’d rather be in an attic, crawlspaces can be low, wet and critters crawling around, in attics just have to worry about the heat and not stepping through the ceiling 😊
@RustyDodd
@RustyDodd 3 месяца назад
Where I’m at, most seem to be in the attic
@rayofsunshine107h
@rayofsunshine107h 3 месяца назад
@@RustyDodd Wow...Im trying to get used to that but its hard. My new home has it in the attic...Im just trying to stay ahead of being it proactive...thanks for sharing.
@dfirth224
@dfirth224 3 месяца назад
130 degrees in the attic. What do you think??
@andreakeeling9217
@andreakeeling9217 Месяц назад
You sound like you have asthma.😢 10:30
@michaelbuxton9368
@michaelbuxton9368 3 месяца назад
Wow😮 why not replace the board?
@markbeiser
@markbeiser 3 месяца назад
Board not stocked on truck. Board costs several times what the relay costs. Board just delays the blower turning on and off to give an extremely small boost in SEER ratings. Difference in cost between installing new board over ditching it in favor of a relay would take a decade or more to get back in whatever energy saving there may be. Board failing already wasted more energy and the customers money than there was ever any potential for saving over the life of the equipment.
@dfirth224
@dfirth224 3 месяца назад
@@markbeiser Anyone can replace a board, but you have to be smart to figure out a better way.
@joeds3775
@joeds3775 Месяц назад
Board is 400 and relay is 10. Relay in back of van, board in China.
@BlueMonte-v8k
@BlueMonte-v8k 2 месяца назад
He handled the call with extreme precision. His diagnosing skills are grade A. Your a certified boss out here. Job well done bro. Love the videos keep going!!!
@JohnSmith-ug5ci
@JohnSmith-ug5ci 3 месяца назад
Good job.
@HVACGUY
@HVACGUY 3 месяца назад
Thanks!
@MelvinWilson-k8v
@MelvinWilson-k8v Месяц назад
White Paul Davis Nancy Lee Gary
@timbrown9305
@timbrown9305 Месяц назад
Always $75 extra for crawlspace.
@lynncomstock1255
@lynncomstock1255 3 месяца назад
After installing a new high efficiency AC, the very next month the customer was outraged to receive a bill about one thousand dollars greater than ever before. It turned out that the energy provider misread the meter. Rare. It occurred only once in my career.
@d.c.3220
@d.c.3220 2 месяца назад
That is rare considering many more meters these days relay data electronically. Nearly 80% of the meters in the US are smart meters. Meter readers are going extinct fast.
@ksavage681
@ksavage681 2 месяца назад
How is 2000 dollar bill even possible?????
@qball6520
@qball6520 14 дней назад
Dude, you seem to be clueless with tools.
@steakhouse45
@steakhouse45 Месяц назад
What kind of bit do you have on the end of the gun 6:04
@ursulasmith6402
@ursulasmith6402 3 месяца назад
Iam moving way north, enough of the heat.
@joehrlein847
@joehrlein847 2 месяца назад
Supposedly Duluth MN is the place to move to because of climate change. Duluth has cooler summers, in the seventies, but winter is cold. If you're into winter activities, snowmobiling, ice fishing, ice skating, cross country skiing, etc. Duluth is on Lake Superior and close to Canada. It's a nice small city with a craft beer scene. The nearest big city is Minneapolis about 160 miles south.
@JoseFernandez-ly7qs
@JoseFernandez-ly7qs 3 месяца назад
Replace that thing its old and inefficient
@MargaritaSimpson-c1p
@MargaritaSimpson-c1p Месяц назад
Hall Mary Moore Michael Harris Linda
@DirtyPlumbus
@DirtyPlumbus 3 месяца назад
Central air is stupid anyway. The majority of your money is just lost through the duct work. You're better off having an AC in every room. It will be vastly more efficient and cheaper.
@RayleighCriterion
@RayleighCriterion Месяц назад
My AC is blowing non cool air, I know I'll leave it on for a month and rack up a 20 amp load 24 hours a day for 30 days. Come on people, unless you live in Death Valley, your AC should never be running 24 hours a day non stop.
@terryh8421
@terryh8421 3 месяца назад
Good video.
@HVACGUY
@HVACGUY 3 месяца назад
Thanks!
@SoddenVelvet
@SoddenVelvet 3 месяца назад
You literally just saved this house from burning down 😳
@kuhrd
@kuhrd 3 месяца назад
That is the reason electrical wiring and controls in metal boxes and enclosures are the safest option. The odds of that relay failure causing a fire are pretty low because it is enclosed in metal. If it started burning the wires eventually it would short out to the chassis or break the circuit and by that point you would smell the electrical fire inside the house and could safely get out of the house and eventually investigate the issue.
@bobboscarato1313
@bobboscarato1313 3 месяца назад
@@kuhrd Don't forget to turn the breakers to OFF.-
@SoddenVelvet
@SoddenVelvet 3 месяца назад
@@kuhrd at the same token electricity doesn't play I've seen some freaky shi behind electrical failures etc.
Далее
An Unusual No Cooling Call
22:56
Просмотров 163 тыс.
Odd Complaints Lead to Scary Find! #hvacguy #hvaclife
29:11
ОБЗОР НА ШТАНЫ от БЕЗДNA
00:59
Просмотров 242 тыс.
11 ming dollarlik uzum
00:43
Просмотров 625 тыс.
You're wasting money on heating! Use your A/C!
17:11
Просмотров 537 тыс.
The Mini Split - REINVENTED.
31:23
Просмотров 328 тыс.
Using A Multimeter With HVAC Schematics
31:30
Просмотров 16 тыс.