Тёмный

FNIRSI 1014D Oscilloscope REVIEW 

Astro's Electronics Lab
Подписаться 3,2 тыс.
Просмотров 6 тыс.
50% 1

Опубликовано:

 

16 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 22   
@Amplified208
@Amplified208 9 месяцев назад
Congratulations on the new scope, it will make the projects more enjoyable.
@AstrosElectronicsLab
@AstrosElectronicsLab 9 месяцев назад
Thanks! Indeed, it will.
@paulharrow7897
@paulharrow7897 6 месяцев назад
A genuine unboxing with no preparation, lol. Enjoyed watching you figure out how to adjust the function generator frequency after having the same experience myself when I first got it.
@AstrosElectronicsLab
@AstrosElectronicsLab 6 месяцев назад
Yeah. I didn't look at any reviews, just fumbled my way through it. Learnt a few more things later. That's the fun of it!
@axw40azou39
@axw40azou39 8 месяцев назад
good channel , i want buy one for my physic experiments
@AstrosElectronicsLab
@AstrosElectronicsLab 8 месяцев назад
As I said in the video, this is a basic, cheap, entry-level 'scope. It does the job, but it's by no means "professional".
@graxav
@graxav 3 месяца назад
I use a passive high quality attenuator ballanced XLR with short cables for the sig gen with no noticeable deterioration. Can pull it down to 50 mv RMS no probs.
@AstrosElectronicsLab
@AstrosElectronicsLab Месяц назад
Interesting. Can you perhaps share a schematic?
@bobisyouruncle1
@bobisyouruncle1 6 месяцев назад
Hi Sir - are you content with the fnirsi 1014d? Have you encountered any shortcomings whilst testing or repairing projects?
@AstrosElectronicsLab
@AstrosElectronicsLab Месяц назад
I'm happy with it. No, no real shortcomings. The only issue is when trying to measure frequencies down in to the low Hz, the refresh rate (drawing rate) of the screen slows down considerably.
@atlanko1
@atlanko1 8 месяцев назад
30Mhz, it had a sample memory of only 3000bytes, it does not display a signal below 35mV on the 100mV range. Sensitivity 100mV, overall bad software. Did I forget something?
@paulharrow7897
@paulharrow7897 6 месяцев назад
The terrible quality of the rotary encoders? Each time you turn it off and then on again, it decreases the time base by one step...actually that's kind of a cute quirk. :-) I'm enjoying mine, but it really is a toy more than a tool.
@AstrosElectronicsLab
@AstrosElectronicsLab Месяц назад
Mine doesn't do that.
@beachdancer
@beachdancer 7 месяцев назад
Only having one channel trigger. Doesn't that mean that if you compare the input signal and the output signal of a circuit, only one of those traces will be stable? The other one will be rolling across the screen or bouncing around?
@AstrosElectronicsLab
@AstrosElectronicsLab 7 месяцев назад
No, I actually found this to be fine. Both display fine. It's only if you monitor 2 different sources/types (eg one sine other square) that it doesn't trigger right.
@bobisyouruncle1
@bobisyouruncle1 6 месяцев назад
Hi - Provided both input and output signal you measure have the same frequency, regardless of amplitude, you may set the trigger on any of the channels and the signals will be stable. As i said, the frequency of both signals must be the same, otherwise the signal which is not triggered, will bounce around
@soapboxearth2
@soapboxearth2 2 месяца назад
Would this be adequate for testing tube amps?
@AstrosElectronicsLab
@AstrosElectronicsLab 2 месяца назад
With the right probes, yes. As this is isolated from the mains earth, it should be fine. Just be aware of the high voltages, use an isolation transformer and common sense.
@soapboxearth2
@soapboxearth2 2 месяца назад
@AstrosElectronicsLab thanks for the reply. I ordered one . I was wondering how high of a dc v can these handle
@AstrosElectronicsLab
@AstrosElectronicsLab 2 месяца назад
@@soapboxearth2 40v at x1, 400v overload protected in x1 according to manual
@steveone
@steveone 9 месяцев назад
You can get away with bending the parallel prongs to the Aussie angle if youre in a bind . Ive done it a few times with phone chargers .
@AstrosElectronicsLab
@AstrosElectronicsLab 9 месяцев назад
So have I. I just don't like doing it, as sometimes it doesn't fit in the socket correctly. This can lead to accidentally contacting the prongs with your fingers when removing it, as these do not have "safety" insulation at the end of them.
Далее
Another cheap scope: $18, shipped! (FNIRSI DSO152)
51:30
@HolyBaam ультанул в конце 🧨
00:34
Просмотров 347 тыс.
FNIRSI 1014D - How to use the signal generator
16:31
Просмотров 20 тыс.
Philips PM3055 Short review and test.
9:02
FNIRSI DSO-TC3 Teardown
13:20
Просмотров 19 тыс.
The FNIRSI-1013D Tablet Oscilloscope - A Review    #052
21:41
Hantek DSO2C10 Oscilloscope Review and Tear Down
22:17