Тёмный

GAUSS SEIDEL LOAD FLOW SOLUTION(PROBLEM 3)WITH REACTIVE POWER CONSTRAINT/ KTU/ POWER SYSTEM ANALYSIS 

praveen raj
Подписаться 6 тыс.
Просмотров 50 тыс.
50% 1

Опубликовано:

 

10 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 35   
@joeempire3803
@joeempire3803 Год назад
That was one of the best lectures I have had so far... THANK YOU
@niteesh4190
@niteesh4190 3 года назад
Excellent explanation sir
@laka_bau5901
@laka_bau5901 4 месяца назад
Thank you very much! You have helped me more than you can imagine! Thank you SO MUCH!
@pollobgoswami9656
@pollobgoswami9656 2 года назад
sir, your videos are very useful and easily understandable
@praveenkumarlk8527
@praveenkumarlk8527 Год назад
thanks for explaining the step by step method, easily understandable.
@kalvakolanushreya
@kalvakolanushreya 16 дней назад
Awesome
@exploreplaces960
@exploreplaces960 2 года назад
Thank you so much Sir! Nice technique of explanation 👍
@halimasiddiqui3470
@halimasiddiqui3470 4 месяца назад
thank you so much sir for the clarity with calmness
@FARHANALI-zt5tx
@FARHANALI-zt5tx Год назад
Very good explanation sir. It's help me alot. Thanks sir
@nandanagopakumar7631
@nandanagopakumar7631 2 года назад
Sir while finding V3 why didn't you take the value of P3 &Q3 as -ve since it is a PQ bus
@saaho-m
@saaho-m 9 месяцев назад
i guess we need to take negative sign if its given as P(demanded) and Qd in question
@dilipverma9234
@dilipverma9234 Год назад
Sir , what about the values of P1 and Q1 , Slack bus power We don't need to find P1 and Q1 values , and if we need to find them then P1 and Q1 will be positive or negative?
@anjalikrishna6058
@anjalikrishna6058 2 года назад
sir one doubt please .it is a pq bus .so the value of p and q while calculating voltages should be negative?
@alanjaison5041
@alanjaison5041 3 месяца назад
Yes
@sengsomakarin
@sengsomakarin 3 месяца назад
Thanks you sir.
@k.v9853
@k.v9853 3 года назад
thank u so much professorji
@sathiyalokeswaranlingeswar5062
such a clear explanation
@madhu8859
@madhu8859 2 года назад
very nice explanation sir..thx u so much
@chifonlesley3011
@chifonlesley3011 Год назад
wow thanks very much sir 🙏🙏
@tanviralgalib1909
@tanviralgalib1909 Год назад
Very good . Thanks
@surendrakverma555
@surendrakverma555 2 года назад
Excellent. Thanks 🙏🙏🙏🙏🙏🙏
@muneeramn1872
@muneeramn1872 11 месяцев назад
what if, calculated q is in in between range.then how to proceed...please can you say sir..
@pvsnarayana
@pvsnarayana 2 года назад
Sir if possible kindly explain about NR Load flow sir
@niteshkhanna690
@niteshkhanna690 6 месяцев назад
🤧🤧🤧🤢🤢🤢🤢🤢🤢🤮🤮🤮🤮🤮🤮💯💯💯💯
@ShwethaDravidSIEE
@ShwethaDravidSIEE Год назад
Thankyou so much sir...❤️👍🏻
@siriaggarapu4679
@siriaggarapu4679 2 года назад
sir if in question they gave the Q value but they did not given the p value then how to find out P valu esir
@anjalikrishna6058
@anjalikrishna6058 2 года назад
they ll give
@simoniqbal69
@simoniqbal69 9 месяцев назад
hello sir you have calculation error at 32nd minute of the video while you were doing the first iteration of v2
@champakdaas
@champakdaas 10 месяцев назад
Great sir
@narechowdaiah3911
@narechowdaiah3911 Год назад
Sir please do videos on nr method and fast decoupled
@pvsnarayana
@pvsnarayana 2 года назад
Sir excellent
@anushakaroshi_0954
@anushakaroshi_0954 3 месяца назад
29:12
@sunnyahmed5935
@sunnyahmed5935 2 года назад
thank u so much sir
@ivininasuchungath8012
@ivininasuchungath8012 Год назад
Why you didn't consider acceleration factor?
@saaho-m
@saaho-m 9 месяцев назад
i guess we need to take it if its mentioned
Далее
Newton Raphson Load Flow Solution - 3 Bus - Part 1 of 3
24:34
Newton Raphson Iterative Technique (NR Method)
55:29
Просмотров 35 тыс.
Can Jewel Bearings Be Pressed In The Home Shop?
17:37
Symmetrical Components
39:09
Просмотров 31 тыс.
Power System Stability | Part 1 (Basics)
35:04
Просмотров 103 тыс.
Power Flow Equations Part 1
7:15
Просмотров 88 тыс.