Generator Cord Wiring | How To Make Up A Cord | L14-30R 

Conquerall Electrical
Подписаться 6 тыс.
Просмотров 59 тыс.
50% 1

In this video we demonstrate how we make up a generator cord for our customers. We have put some links below or come over to
conqelectric.com
Link:
USA
amzn.to/3oKUeEJ
Canada
amzn.to/365cPol
This channel has a membership to Amazon Associates, an affiliate program structured to provide earned commissions by advertising or linking to Amazon.com. As well as other advertisers.
These videos are created as educational and entertainment videos on this channel. In no case are we suggesting that you do your own electrical work without a proper license to do so. Please consult your local licensed tradesperson. Conquerall Electrical Ltd is liable for incorrect information, assumes no liability for damage or injury. Check with the inspection authority and building codes in your local area. Conquerall Electrical Ltd will not be held liable for any accidental damage, negligent or injury resulting from equipment, information, electrical, tools, fire, recommended products or any items contained in this video. The information provided is based of CEC knowledge and not NEC. We are a Canadian based company.

Наука

Опубликовано:

 

22 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 37   
@al7385
@al7385 3 месяца назад
Absolutely excellent presentation and also shows the value of paying attention to detail, which is critical where safety must be a concern.
@__-hb2kt
@__-hb2kt 2 года назад
You made this really easy to understand thank you so much and the extra information about amps and watts, it made so many other things come clear for me. I really appreciate it.
@joshm3342
@joshm3342 21 день назад
Missed one test at the end @19:25: Check ohms ACROSS all combinations of male terminals, just to be CERTAIN that there are NO SHORT CIRCUITS. The end-to-end tests and the short-circuit tests should be performed on ANY cable that you buy, have built, or otherwise obtain. You don't want to find out there's a problem with live power energizing your cable!
@bryanphillips8542
@bryanphillips8542 Год назад
Simple explanation. In a 4 pin 220 volt male generator plug, the locking terminal (the bent one) is the ground. Opposite that is neutral and the other 2, similar in appearance to each other, are lines 1 & 2. (Power) If you need to run an extension cord to power up a trailer normally fed by 220 volts but not running 220 volt appliances, you can 'cheat' a bit by connecting two wires together. (2.5 mm 3 core flex minimum, 2 core flex may be used but would require bridging out pins 1&2 inside the 220 plug housing) Using the smaller pin on a 2 pin 110 volt male plug, connect two wires. (With a 3 pin 110 plug, the round pin is not used) Then connect those two wires to each of the power pins (lines 1&2) in the locking 220 volt male plug. Next, connect another wire to the remaining large pin in the 110 volt plug and connect that to the neutral pin in the 220 volt male plug. This will safely feed all the 110 volt circuits. Be careful not to overload the system. Remember this is a 'cheat' system so a degree of caution is required. More importantly, be sure to plug in the 220 volt male plug to the 220 volt female receptacle on the trailer *before* plugging in the 110 volt power supply as the prongs on the male plug will be live. I've used this system with great success on a number of trailers and small areas for 'temporary power' when 220 volt power is unavailable.
@user-qq8xe9oz1y
@user-qq8xe9oz1y 4 месяца назад
Appreciate the video and your down to earth explanation! Thanks again
@flopipr
@flopipr Год назад
Thank you for your video I have been searching for Videos and watching Videos for about an hour and a half and none of them could help me since they did not explain well or omitted steps to follow yours helped me a lot thanks
@marthawilson1318
@marthawilson1318 Месяц назад
this was extremely helpful & useful but i really wish i could see how you determined what wire goes into what hole. other than that this was pretty much what i needed
@Driller4664
@Driller4664 Год назад
Great video. I’m dealing with 6kw and 20kw generators with 30 amp 250 volt 3 prong receptacles and need to power 30amp 125 volt RV’s. Have one custom built adapter, but need to build 2 more.
@brucecaplin
@brucecaplin Месяц назад
thank you
@joshm3342
@joshm3342 21 день назад
NEMA (National Electrical Manufacturers Association) does not MAKE cables, but some of their members do.
@davidgeske7898
@davidgeske7898 11 месяцев назад
very helpful thank you
@unseen_stranger
@unseen_stranger Месяц назад
I have a four prong 220V generator & a 3-wire 220V condenser. Does this summary make sense? G = ground = green X = L1 = black Y = L2 = red W = neutral = white (unused in this case, as the condenser is single phase)
@master6435
@master6435 9 месяцев назад
What happens when someone makes two cords but one cord the red cord in on X and the other cord the red is on Y?
@joshm3342
@joshm3342 21 день назад
See @3:35 in the video: "doesn't matter".
@rickybaby69
@rickybaby69 Год назад
Excellent video
@BKsn00py
@BKsn00py Год назад
What a good tutorial thanks!!
@troyd.521
@troyd.521 Год назад
My generator has a 30a 4 prong female receptacle . I bought a 50 amp inlet plug box by mistake. I plan on using a 30 amp breaker but would like to still use the 50 amp inlet in case I get a larger generator down the road I can swap the 30 amp breaker for a 50 amp. (I’ll use 6 gauge wire when installing the inlet plug). So, how do I wire it up with 30 amp male plug and 50 amp female? What do I do with the extra wire?
@mojodrum3215
@mojodrum3215 2 года назад
Thank you for this very well explained video. I just purchased a champion 10000 watt startup and 8500 watt running generator and also purchased a 30 amp Generlink. My question is can l run my 2 ton ac with this setup along with a freezer, fridge, microwave and some lights. I see some comments explaining that the 30 amp cord could catch fire and that you should use a 50 amp setup.
@PoisonShot20
@PoisonShot20 Год назад
Sure you can, I have the same set up as you, but my cord is only 30 feet. My AC is 3T, and I have , 3/4hp well pump, 100' deep + lights fridge. My generator is a Troybult 7000 running watts and 10500 starting watts. Ran one time for 3 days.
@bencoverley5748
@bencoverley5748 9 месяцев назад
Hi It’s very Interesting I am a U.K. electrician and I want to understand the USA plugs but the ones I am stuck on are the non-nema California standard wiring what terminals are beurtral ground and the hot wire ? Thnaks
@nkel6111
@nkel6111 Год назад
nothing personal but you did not really identify what screw ends were hot and what was the neutral conductor. I see X, Y, and a W. Under normal circumstances I would assume G is ground and W is neutral and x and y are hot legs...but the male plug end I just bought has 3,(three) screws, are all brass colored. All brass !!!. My point is ...I expected a silverish one for neutral ......and it's not... I see a W but with leviton's miscolored screw mistake. leviton is suspect. thanks if you answer. its storm of the century tonight.
@EastCoastWingNuts
@EastCoastWingNuts 6 месяцев назад
How many feet away can you have the Gen. from the inlet box ? how long can the wires be ? 10 gauge . looking to have the wires 100 ft. long to get the Gen. where I want it
@stephengraham981
@stephengraham981 2 года назад
What do you do when the outlet on your Generator is 3 wire 120-230-30 in other words you have a 4 wire female plug at the house and 3 wire male at the generator can I simply not hook up the neutral since a3 wire cord would not have a neutral
@conquerallelectrical
@conquerallelectrical 2 года назад
Sorry my friend you will need a 4 wire generator to supply to outlet. Do not hook it up without a neutral connection. You will cause all 120 volt loads to get 240 volt and blow them up. Hope this helps
@gps2119
@gps2119 Год назад
Hello fellow maritimer. I'm in Halifax. I built a generator shed and insulated it. I have 2 30amp 240 volt cables made ,each at 45 ft. My shed is 90 ft away from the house. I have a Firman 7500 cold start. W My question is, does this cause a problem using 2 cables. They are both 10-4 SOO cables. Cheers
@belindac4422
@belindac4422 Год назад
I took mine apart cuz I thought I needed a diff end for my new coffee truck and now I want to put back together but my wires are red black white yellow. I have a W , X , Y, and G Which goes where? Help!
@VworksArt
@VworksArt Год назад
Can you make a cable by shielding THNN cable?
@rickiaratyson6425
@rickiaratyson6425 4 месяца назад
My food truck has a l14-30p that I need to connect to my generator that has a l14-20r could a cord made with these two ends work?
@ericklein5097
@ericklein5097 3 месяца назад
Technically no, your food truck has a 30A receptacle for a reason. Unless you know for a fact that you are only using 20A at 240V then you are asking for trouble. The fact that your generator only has a 20A receptacle leads me to believe it can’t handle the 7.2kw you could pull from a 30A (but circuits are typically derated by 20%…I would assume generators do that too?) I would change out what’s on your food trailer to a 20A after confirming 20A is enough for everything in there. OR Buy a bigger generator that has a 30A receptacle
@user-zk5wn2jb8s
@user-zk5wn2jb8s Год назад
It seem that you don't want us to see wich wire go on wich pin.
@taz10029
@taz10029 Год назад
What if the cable only has 3 cables on the inside? Green, white, and black.
@conquerallelectrical
@conquerallelectrical Год назад
This will not work for that proper set up unfortunately.
@Digidoc316
@Digidoc316 Год назад
Slight disagreement about the big box 10-3. Typically, they will give you Romex in which the ground line is NOT included in the description. A piece of 10-3 Romex contains the black, the white, and the red which are all insulated; it also includes the ground which is uninsulated. However, due to the "flat pack" style of Romex, it is not well suited for a generator cable. In a SOW cable, ALL the conductors are insulated.
@conquerallelectrical
@conquerallelectrical Год назад
We are not permitted to use Romex in Canada, so I'm sure that is where we differ...
@Digidoc316
@Digidoc316 Год назад
Made by NEMA? I thought NEMA was the National Electrical Manufacuters Association. You said "NMD or Romex you would buy for house wiring" so then you are permitted to use Romex but presumidly not for a generator application which just makes sense.
@bluefallon6374
@bluefallon6374 Год назад
I just bought a bandsaw and it has 3 prongs, which means 3 wires and it is 240 , and so my generator has a l 14 - 30 30 Amp 4 wire receptacle , I’m off the grid so my choices are limited , got any suggestions?
@freddyg9026
@freddyg9026 Год назад
probably like using a welder, just dont use the neutral
Далее
What is a Suicide Cord and Why It Could Kill You
16:28
4 Generator Hacks by an Electrician
6:45
Просмотров 300 тыс.
Make A 30 Amp Generator Cord
14:26
Просмотров 107 тыс.
BEST Generator Cord is the One you Can Make Yourself
6:29
Adapters for Home Backup & Generators
26:30
Просмотров 13 тыс.
How NOT to Make a Generator Cord
2:51
Просмотров 83 тыс.
Extension Cords On A Generator? No, Yes, Mbe...
6:45
Просмотров 142 тыс.
Samsung Galaxy S24 Ultra Vs Iphone 15 Pro Max
0:56
Atajos de Teclado en Excel para Eficiencia
1:31
Просмотров 64 тыс.
ноутбуки от 7.900 в тг laptopshoptop
0:14