Тёмный

GX Works 2 : ADD,SUB,MUL,DIV instruction mitsubishi PLC FX series connected with HMI simulator 

Automationliker
Подписаться 2,8 тыс.
Просмотров 9 тыс.
50% 1

Arithmatic instruction mitsubishi PLC.
ADD (+) SUB (-) MUL (*) DIV (/)
simulation with HMI GT designer 3, training become easy to understand
#plc #ladderdiagram #mitsubishi #automation #gxworks2 #plcprogramming

Опубликовано:

 

8 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 15   
@bobbym6964
@bobbym6964 2 месяца назад
Learned how to program the HMI and the choice of music was WONDERFULL !!
@automationliker
@automationliker 2 месяца назад
Thanks For Watching this Video...
@Kannvanlan
@Kannvanlan 3 месяца назад
Why when you push on X2 D0= 10 Value can explain please.
@automationliker
@automationliker 3 месяца назад
Because ADD instruction. program >>> [ADD D0 K10 D0] means Data D0 add by 10 and store to D0 every 1 Trigger..
@Kannvanlan
@Kannvanlan 3 месяца назад
@@automationliker it should D0 =0 Value + K10 =10 ?
@automationliker
@automationliker 3 месяца назад
@@Kannvanlan yes like that
@Kannvanlan
@Kannvanlan 3 месяца назад
@@automationliker Thank you next video can you make Analog input and analog out put videos for Q Series cpu Thank for shared knowledge.
@alchris2978
@alchris2978 12 дней назад
The ADD instruction is not working. The one on the third rung.
@automationliker
@automationliker 12 дней назад
Check again your Switch address must same with Switch HMI address.. Also Check ADD Instruction. If you Follow this video, i think its Works
@automationliker
@automationliker 12 дней назад
@@alchris2978 and you must make sure that Mitsubishi PLC Type is FXCPU, ADD instruction only works on FXCPU
@alchris2978
@alchris2978 11 дней назад
​@@automationlikerThank you. I was using a Q series
@carlosmatta.p1723
@carlosmatta.p1723 Год назад
¿Ws necesario tener el plc conectado? para simularlo ya que le doy en SIMILAR,pero me manda un error 0180840b correspondiente con un tema de conexión con plc. No sé, si es necesario tener conectado veo plc para poder silumarlo.
@automationliker
@automationliker Год назад
This simulation for GT Designer3 and GX Works2 No need PLC Connected
@automationliker
@automationliker Год назад
If error appear, maybe you want to write program but Communication error (Maybe from cable, COM setting, etc)
@carlosmatta.p1723
@carlosmatta.p1723 Год назад
@@automationliker pero el tema del cable, la configuración COM - son para el tema del conexión con el plc ¿Existe algún error, que se presente en el momento que uno intenta iniciar al configuración?