Honda em5000sx Generator Testing Automatic Voltage Regulator AVR No Power Output 

shango066
Подписаться 80 тыс.
Просмотров 71 тыс.
50% 1

Diagnosing Honda EM 5000 SX Generator with no voltage output. The rotor is bad in this generator, it took some time to figure that out. The Fix for this generator was: apply 12 volts to the rotor to start the loop, slowly load the generator down with more and more equipment starting with one 100 watt light bulb until the generator would self support the load. Once the generator was able to support 1000 Watts it worked as it should Basically the generator required a HARD CORE flashing of the field. Generators need to be started and used every quarter minimum if they are expected to work when needed.

Наука

Опубликовано:

 

10 апр 2012

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 30   
@corlissmedia2.0
@corlissmedia2.0 2 года назад
I really enjoyed watching you investigate what was going on with this angry generator.
@geraldmartin9751
@geraldmartin9751 Год назад
Thanks so much for the tip on flashing the field. that did it for me. Your you tube example helped considerably.I used the generators start battery for the field flash with the connectors to to the stator windings disconnected(did not hold flash) connected the stator windings and the flash held and the voltage came up to spec. Gerald Martin
@glenwoofit
@glenwoofit 9 лет назад
When I used to repair these generators we'd look at the AVR then test the diodes on the rotor shaft (7 out of 10 times it was the diodes) then check winding insulation resistance and continuity. And either rewind the stator replace the diodes or repair the AVR.
@RODALCO2007
@RODALCO2007 12 лет назад
Disconnect one winding. so you have two ends floating, connect a 1.5 or 6 volts battery briefly across it. but also a NE 2 neon globe with 100k resistor to protect the neon. Disconnect the battery, leave neon connected. The kick back from the winding will make the neon glow briefly. then winding is ok. if neon doesn't glow there are shorted turns. Test it with an good transformer to see if your simple circuit works.
@RODALCO2007
@RODALCO2007 12 лет назад
That generator is worth while fixing I think. At least do an autopsi on it and check continuity of the windings and insulation tests in case there is a short to the steel shaft. The stator windings don't look burnt. normally dark brown colour is visible in case of shorted turns. Do the Neon lamp flash test on the windings.
@bodybuildingking
@bodybuildingking 11 лет назад
My bad! I was accidentally looking at ohms for the 3500 rotor on the wrong page. Yours does ask for the higher reading of 55-65ohms. Lots of sitting generators do require backfeeding to re-energize the field from sitting. Good informative video btw.
@cbsolo5628
@cbsolo5628 Год назад
Rotor connects go the motor shaft via a tapered coupling. Been there did it.
@jamesbarratt593
@jamesbarratt593 8 лет назад
The rotor is held there by the centre bolt, on the engine side it is probably tapered or fits on to a parallel shaft. My Loncin I change the rotor and stator which was recommended as doing together. You are saying its the rotor but unless you binned the machine or lost interest because you mentioned stripping it looked like a big job, what happened. Did you ever fix it and what was the answer? I am dubious about the rotor being at fault but very keen to find out what it was. Please tell me you fixed it.
@joecantu5776
@joecantu5776 5 лет назад
V, luv
@norvanl.johnson9331
@norvanl.johnson9331 10 лет назад
Where did you get a copy of the schematic? Would it be possible to get a copy? I have a Honda generator with a sawfuji B50 generator with a bad Stator. It has a plug on the bottom that must adjust for frequency or something. Replacement generators do not have this set of wires. So I am wondering what they do.
@DougKalmer
@DougKalmer 8 лет назад
My friend burned a stator in his EM5000SX Honda generator and gave it to me, tried getting it rewound, didn't work, long story, so I bought a new stator for $736 but have a wiring problem in that the four wires coming from the new stator are green, red, black and yellow, while the four from the harness they are supposed to connect to are gray, red, blue and white. Can anyone tell me how to connect them or how to figure it out? Thanks, Doug
@alborgdenmark26
@alborgdenmark26 4 года назад
What are the ratings/values on the Variac that you are using?
@gbean
@gbean 5 лет назад
I wonder whatever happened with this? I've dealt with many of these Honda 5000W units for fun on the side (I'm a professional generator tech on large commercial and industrial systems.) If the rotor were open or shorted you'd likely never have any output no matter what you tried. I'd think either the AVR is the exciter winding or wiring have an issue.
@gbean
@gbean 5 лет назад
After watching you try to put a load on it, I'd bet a new regulator would get this going.
@isettech
@isettech 8 лет назад
Need to improve your test proceedure. Unplug the exciter from the regulator and connect a meter. Connect a variac to the regulator. With varia at zero start the generator. Measure the exciter voltage. Adjust the variac to match the exciter. Did the exciter voltage increase? If not the machine won't build. This can find bad diodes, or other regulator problems. AC in to AC out should be a fixed ratio up to core (iron) saturation or the regulator operation. Graph it. Problem is either shorted turns on the rotor (field, exciter, or main), or bad diodes or cap in the regulator. Chart a good machine and compare volts in vs volts out to verify rotor, or exciter problems, vs regulator problems.
@rizwanpc
@rizwanpc 10 лет назад
Does it worked after replacing the rotor? i have exactly the same problem with my generator....
@rizwanpc
@rizwanpc 10 лет назад
It didn't worked.
@rizwanpc
@rizwanpc 10 лет назад
Thank u for your reply but I have recently replaced the stator windings and afterwards it is working alright
@MrBugsier5
@MrBugsier5 10 лет назад
Actually its dc on the brushes!,,, i think there is a loose solder connection on the sliprings, or defect brushes.if the avr is good , en you apply dc on the brushes and then it should work, iff nor rotor failor just loose wire somwhere.
@bodybuildingking
@bodybuildingking 11 лет назад
Where did 60 ohms on the rotor brushes come from? Specs I have say it should be 45-55ohms. Any higher and the rotor needs replacing.
@gbean
@gbean 5 лет назад
Through the brushes a 5-10 ohm variance is acceptable.
@thebandfromhull
@thebandfromhull 12 лет назад
you need to test the output voltage across the brushes, it should be anywhere up to 10 volts ac then between the field coils R1 & R2 L1 & L2 it should be around 5 volts ac on each coil test with avr removed if all three tests are good then the avr is breaking down
@grantconeys9551
@grantconeys9551 11 лет назад
Has any one had a problem with high voltage? 142 volts not 120 and 280 not 240?the meter also shows 60Hz?
@chaonachatepa9802
@chaonachatepa9802 12 лет назад
You see, I have a similar problem with my generator, model no.E P 5500. It is up and running but there is no voltage output. Again the stator windings don`t look bun`t. Everything seem quiet OK. So, could you please come in and help me as well.
@HDXFH
@HDXFH 9 лет назад
may need a permanent battery hook up to excite it, annoying!!, weird why it doesn't retain magnetism though!!
@robertomezaperez2828
@robertomezaperez2828 5 лет назад
Se observa que no sabe nada de inducción. Que pena.
@4u2cJoeD
@4u2cJoeD 7 лет назад
Diode. poor rpm, htz thats failuer
@CPUTests
@CPUTests 11 лет назад
My friend, don't put DC current on the brushes. They ment to work on AC. That way you'll fu@# the regulator.
@gbean
@gbean 5 лет назад
This is incorrect. The field power voltage (through the brushes) is DC. There is no rectifier on the rotor or anywhere part the regulator on Honda generators.
@actorzone856
@actorzone856 8 лет назад
If it does not work take it apart and test everything,
Далее
Generator Voltage Regulator Explanation
6:20
Просмотров 6 тыс.
Honda EB 3000c Generator Won't Run?
22:23
Просмотров 7 тыс.
Portable Generator End Testing (AVR & Brush)
15:23
Просмотров 215 тыс.
4x Quieter generator in 10 seconds
10:35
Просмотров 4,4 млн
No Power Output - Will Flashing the Field Restore Power?
1:39:52
Troubleshooting Generator No Power Output and Fix
21:14
Generator Repair - Troubleshooting - Runs But No Power
13:34
iPhone socket cleaning #Fixit
0:30
Просмотров 18 млн
Самая редкая видеокарта NVIDIA
1:00