-Honeywell Sense point XCD O2 Fixed Gas Detector range provides comprehensive monitoring of flammable, toxic, and Oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors. Outputs are automatically inhibited during adjustment, thereby reducing the risk of false alarm at the control panel during maintenance.
Applications: hazardous area locations.
Features of Honeywell Sense point XCD O2 Fixed Gas Detector:
-Honeywell Detector is user friendly and intuitive tri-color backlit display with digits, bar graphs, and icons.
-Different types of versions available such as Flammable, toxic, and oxygen.
-It has a stainless steel or aluminum explosion-proof housing options.
-IP66 as standard.
-Surecell TM electrochemical sensors.
-It has long life sensors.
-Optional remote sensor mounting available.
-MODBUS communications for remote diagnostics/configuration
-It is Fully configurable via magnetic switches
For Direct Purchase: www.instrukart...
#honeywell #gasdetector #detector #flameproof #flameproofgasdetector
#honeywellsensepointXCD
Connect With Us:
Website: www.instrukart...
Facebook: / instrukartho. .
Call Us: +91-7331110506

Опубликовано:

 

16 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 8   
@Tathagat993
@Tathagat993 3 месяца назад
Great 👍 sir
@InstrukartHoldings
@InstrukartHoldings 3 месяца назад
Thank you sir.
@Tathagat993
@Tathagat993 3 месяца назад
Can you suggest calibration process
@InstrukartHoldings
@InstrukartHoldings 3 месяца назад
Hello, Thank you for showing interest in our product ranges, Can you share your email ID. So our Technical person will reach you soon.
@vishwanathalvishwa1823
@vishwanathalvishwa1823 8 дней назад
It will auto stop when gas is below the set point
@InstrukartHoldings
@InstrukartHoldings 7 дней назад
Please Elaborate your Query Clearly as we can help you with the answer
@prasanthvijimol
@prasanthvijimol День назад
My oxygen sensor giving W 01 alarm..when going SET CAL menu…the reading shows o2 2.0% volume…then Span fail message…please help me to solve this
@InstrukartHoldings
@InstrukartHoldings 22 часа назад
Calibration required with Span gas. However the Sensor may be failed. If so required replacement.
Далее
Russian soldiers get chased by Ukraine drone
00:28
Просмотров 66 тыс.
Какой звук фальшивый?
00:32
Просмотров 335 тыс.
Honeywell XCD - Setting Up Loop Verification
4:26
Просмотров 1,4 тыс.
Honeywell XCD - Setting Alarms and Relays
7:29
Просмотров 3,2 тыс.
How to use the Pressure Calibrator
3:25
Просмотров 2,4 тыс.
What is a Vibration Sensor?
8:17
Просмотров 277 тыс.
Fixed Gas Sampling System on tanker.
19:43
Просмотров 9 тыс.
Sensepoint XCD O2 검지기 교정 방법
1:53
Russian soldiers get chased by Ukraine drone
00:28
Просмотров 66 тыс.