Тёмный

How To Calcium Test In Laboratory? o-CPC Method 

Просмотров 69 тыс.
% 862

This video describes the procedure for performing the CALCIUM CPC Reagent Test from Serum sample by Anamol Laboratories Private Limited, India.
Watch how to program CALCIUM -ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-S_W_0ZswcKk.html
🔴Introduction🔴
Calcium plays an active physiological role in bone mineralisation, neuromuscular excitability, muscle contraction, and blood coagulation. Hypocalcemia can result from chronic renal failure with hypoproteinemia and hyperphosphatemia, or hypoparathyroidism, or vitamin D deficiency (osteomalacia, rickets). The most common cases of hypercalcemia are associated with hyperparathyroidism, tumours and bone metastases, hyperthyroidism or vitamin D overdose. Calciuria has little practical value in the various diagnoses except for the renal tubulopathies. Calcium can be estimated in serum / plasma using o-Cresolphthalein Complexone method.
🔴Features:🔴
• O-Cresolphthlein Complexone Specific To Calcium
• Fe And Mg Intereference Eliminated
• Liquid Stable Reagents With Long Shelf Life
• Fast Result
• High Linearity
• Suitable For Fully Automated Chemistry Analyzer
🔴Specification🔴
• Methodology - o-CPC
• No. Of Reagents - Two Liquids Ready-To-Use
• Shelf Life - 24 Months
• Sample Volume Required - 20 µL
• Test Time Required - 5 Minutes
• Linearity - 15 mg/dL
• Automation - Enabled
More such interesting content, visit the following:
👉Website: anamollabs.com/
👉RU-vid: ru-vid.com/show-UCeoyLahX8RxyBIY6419K_8A
👉Facebook Page: anamollabs
👉LinkedIn Page: www.linkedin.com/company/anamollabs
👉Twitter Handle: anamollabs
Anamol Laboratories Private Limited is focused to share knowledge as it is one of the Core Values on which the company operates. As a part of this value, our channel is focused to provide in-depth knowledge about the products and industry that we deal with.
👇👇👇👇👇👇👇👇👇👇👇👇👇👇👇👇👇👇
Kindly go through the important links and get the information. Incase you want detailed information related to the product, you can just go to each product and there you will get all the details like Product Photo, Video, Specifications and Packaging Information. Once you are satisfied with the product then please contact me with specific details about the product. Hope the information will be very transparent and useful
👉🔴Our Facility: anamollabs.com/ourfacility.html
👉🔴How we build Quality: anamollabs.com/buildingquality.html
👉🔴Our Certificates: anamollabs.com/certificates.html
👉🔴Why us? : anamollabs.com/whyus.html
👉🔴Clinical Chemistry Products: anamollabs.com/clinicalchemistry.html
👉🔴Serology Products Products: anamollabs.com/serology.html
👉🔴Rapid Test Kits Products: anamollabs.com/rapidtestkits.html
👉🔴Laboratory Stains Products: anamollabs.com/laboratorystains.html
👉🔴Immunoturbidimetry Products: anamollabs.com/immunoturbidimetry.html
👉🔴Urine Strips Products: anamollabs.com/urinestrips.html
👉🔴Distributor Form: anamollabs.com/distributorform.html
👉🔴Product List: anamollabs.com/wp-content/uploads/Product-List-Brochur.pdf

Опубликовано:

 

18 дек 2019

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 45   
@FN-nw2wn
@FN-nw2wn 3 года назад
This video is perfectly filmed. Thankyou sir!
@anamollaboratories
@anamollaboratories 3 года назад
Thank you very much sir. Please do subscribe to our channel and share this video with your friends and colleagues!
@learnhowto6811
@learnhowto6811 Год назад
Excellent sir.......
@zilobuzz8833
@zilobuzz8833 Год назад
Thanks you
@mustafeyrab2561
@mustafeyrab2561 5 месяцев назад
Thanks sir
@abdulsaleh6706
@abdulsaleh6706 3 года назад
My calcium cerium test is 10.5 and the lab ref range is 10.30. Is mine high?
@lukeramsingh8961
@lukeramsingh8961 3 года назад
mahoday aapaka bahut bahut dhanyavaad
@anamollaboratories
@anamollaboratories 2 года назад
Thank you. Pls like and share this video and subscribe to our channel.
@alicomando1195
@alicomando1195 8 месяцев назад
Was 11.7 mg /dl little higher?
@sadamgull3689
@sadamgull3689 3 года назад
Thanks sir it help me lot
@anamollaboratories
@anamollaboratories 3 года назад
Thank you very much sir. Please do subscribe to our channel and share this video with your friends and colleagues!
@godsend992
@godsend992 11 месяцев назад
Can we use urine as a sample instead of serum with this kit?
@ramkumarkhadka9366
@ramkumarkhadka9366 2 года назад
should i aspirat standard and blank in every simple or only first if i had 12 sample .? should i wash before every simple by D.water ? please answer me.
@anamollaboratories
@anamollaboratories 2 года назад
Dear Sir, standard and blank need to be run only first time before running the samples. It is best practice to rinse with D.W. between samples also.
@user-dm1uj9wc5g
@user-dm1uj9wc5g 2 года назад
Thanks for this video
@anamollaboratories
@anamollaboratories Год назад
Thank you. Pls share this video with your friends and colleagues and subscribe to our channel.
@murshinamv9411
@murshinamv9411 3 года назад
Why glass tubes are not used for calcium assay?
@anamollaboratories
@anamollaboratories 3 года назад
Generally improper washing of the glass leads to error in result. You can refer to our separate video on this topic - How to clean laboratory glasswares to learn more about it. However, we will make a separate video on this topic for better explain the error!
@lab_technician_fatma
@lab_technician_fatma 3 года назад
Well explain sir☺
@anamollaboratories
@anamollaboratories 3 года назад
Thank you for watching video.
@princihazarika1846
@princihazarika1846 3 года назад
Blank n standard sirf firts bar hi karne se hota hai kiya? Bar bar calcium test karne ke liye blank n standard karna sahiye kiya
@anamollaboratories
@anamollaboratories 3 года назад
Dear Madam, Calcium ka working solution jab hum banate hai to around 1 week tak hum usse store kar sakte hai at 2-8 degree celcius. Lekin jab hum usse room temperature pe use karte hai to uski stability compromise ho jati hai. Isliye hume daily ek baar Blank aur Standard run karna chaihye agar hamare paas daily samples aa rahe hai to.
@anhareludni786
@anhareludni786 2 года назад
Mei tov ye kahun ga ki ager aap ki lab ki ye cheezein constant hai tov 2 weeks kay baad aap ko standard lagana chahiyay. 1. If temperature of lab is constant. 2.if pipetting is constant,i mean 0 pippeting error. 3. If u use always new test tubes free from dust and contamination. 4.if ur analyser is precise and accurate. If incubation time is constant. 6.if tips are contamination free. Then u can use standard after 1 month. But listen if above mentioned are not constant in ur lab then use standard in each batch. Ofcourse u can use blank after one weak.no need to use blank in every batch of tests.
@jyotibharti4331
@jyotibharti4331 4 года назад
Sir factor se kaise pta chlega volume ka kitna serum lenge
@anamollaboratories
@anamollaboratories 4 года назад
Madam, is video me humne explain kiya hai 1:44 seconds pe ki 1 ml working solution me 20 microlitre sample add karna hai. Apko ye information company ke Instructions for Use (Pack Insert ya Literature ya Kit Insert) me mil jaygi.
@jyotibharti4331
@jyotibharti4331 4 года назад
@@anamollaboratories thx
@tgdada9113
@tgdada9113 3 года назад
Sir.... Yaha hame yeah pata Lagta hain ki Hamare body me calcium kite percent hain tell me
@anamollaboratories
@anamollaboratories 3 года назад
Yes Sir.
@vallarasukiramani1143
@vallarasukiramani1143 2 года назад
May I use this procedure for taking sample as bacteria. To find the amount of calcium in it.
@anamollaboratories
@anamollaboratories 2 года назад
Sir, this kit is intended to be used on human samples. However, you can try at your level using bacterial samples.
@saivineeth8308
@saivineeth8308 3 года назад
who many rupes teast
@shraddhakartikey6269
@shraddhakartikey6269 2 года назад
CPC ka full form kya he?
@aftabkhan2433
@aftabkhan2433 3 года назад
Incubate time pls
@jacquesgenesis1824
@jacquesgenesis1824 3 года назад
Piste kang tawhana ka di ka masabtan
@mrmonu7831
@mrmonu7831 2 года назад
Sir video daliye na sir
@benishamagar4810
@benishamagar4810 4 года назад
Nice brother
@anamollaboratories
@anamollaboratories 4 года назад
Thank you for watching video.
@2002an2
@2002an2 4 месяца назад
What is the name of the machine?
@ayushresearchstudy
@ayushresearchstudy 4 месяца назад
Biochemistry
@micro2232
@micro2232 4 года назад
Sir calcium result came high
@anamollaboratories
@anamollaboratories 3 года назад
Yes sir, it was a high sample.
@KaranJatt1st
@KaranJatt1st 3 года назад
Result was Wrong... U need to Wash it with water b/w Blank,std. And test (specially for Cal.) For accurate result
@anamollaboratories
@anamollaboratories 3 года назад
Sir, it was a high sample.
@hema123lini
@hema123lini 3 года назад
mahoday aapaka bahut bahut dhanyavaad
@anamollaboratories
@anamollaboratories 3 года назад
Thank you very much sir. Please do subscribe to our channel and share this video with your friends and colleagues!