Тёмный

How to Change a Circulator Pump - Hot Water Heating Hydronic 

Andrew W
Подписаться 140 тыс.
Просмотров 65 тыс.
50% 1

In this video I change out a circulator pump in my hot water heating system. It started working intermittently so I had to trouble shoot it and then change it out with a new one.
More videos related to hot water heating boilers:
How a Hot Water Boiler Works
• How a Hotwater Natural...
How to Bleed a Boiler or Heating System
• How to Bleed a Hot Wat...
How a Zone Valve Works
• How a Zone Valve Works...
How to Change a Zone Valve
• How to Change a Zone V...
Instagram:
/ therealandreww
---------------------------------------------------------------------------------------------------------
Amazon affiliate links - these help me build the channel, I get a small percentage of the sale but it costs you nothing though!
Camera Gear I Use to Make Videos:
Canon 80D - amzn.to/2CHTOaT
Sony RX100V - amzn.to/2D5Z3SH
GoPro Hero5 Session - amzn.to/2D8xl85
Canon M6 - amzn.to/2CFHbx8
Rode VideoMic Pro+ - amzn.to/2D7UcQS
Rode VideoMic Micro - amzn.to/2CH7AdT
Lens:
Canon EF-S 10-18mm - amzn.to/2D4sKUt
Canon EF-S 55-250mm - amzn.to/2CH70gd
Canon EF-S 22mm - amzn.to/2yAlj3t

Хобби

Опубликовано:

 

6 дек 2017

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 22   
@61bdelaney
@61bdelaney 6 лет назад
make sure you read TACO installation instructions, Circulator Pump is sold with the electric component on the 9, 12 and 3 o'clock position. They specifically state do not install with electrical component at the 6 o'clock position. This makes sense since if there is a leak from the motor it would leak directly on the 6 o'clock position. Hope Andrew's pump doesn't leak. Otherwise this was a good video and my installation went smoothly.
@EmmDeeVee
@EmmDeeVee 3 года назад
Thanks for putting this out there, Andrew. I have a different brand - Grundfos - where the pump is sweat soldered in place. It still worked, but there was a high pitched grindy noise that started a few days ago. It turns out that there is a replacement cartridge unit with the impeller on it (sits inside the motor magnets) available for my unit that leaves the motor and housing in place (no soldering needed). The cartridge was pump type specific - my pump was a UP 15-18 85 type, whatever that means, which was good, as my pump was no longer made. It was 4 bolts and a bit of persuasion to get the old cartridge out and the new one fit perfectly. It just hums quietly now with the new cartridge. Your video helped save me many hours of cursing/soldering/bloody knuckles. THANK YOU !!! Folks troubleshooting their pump should look at this option if the pump is working, but noisy.
@mintone2008
@mintone2008 3 года назад
Thanks for the video! It helped me save hundreds in paying someone else to fix my problem. Keep up the good work!
@user-kj6ff2xd3k
@user-kj6ff2xd3k 3 года назад
Neat and systematic presentation of the job.
@LuciusKimbleJr
@LuciusKimbleJr 3 года назад
Thanks was just quoted $1385 to replace this
@aprendamosconreneamaya725
@aprendamosconreneamaya725 8 месяцев назад
Thanks 🙏
@NathanThePrezPretlow
@NathanThePrezPretlow 5 лет назад
@t question is this will the newer rubber old ring work with the old flange thats on my boiler or do I need to install a regular flange gasket? Question 2# Whats the prefer nipple to connect to the flange to the boiler brass or galvanize pipe?
@tsfurlan
@tsfurlan 5 лет назад
When these start to go bad does it send out a very loud vibration noise ?
@honeycat535
@honeycat535 4 года назад
im betting your older pu,p just had a loose wire connection, esp if it worked when you slightly moved the unit.
@grandebigy
@grandebigy 5 лет назад
If im repairing my system where should the pump be in relation to the heater ? Its run for years off the hot side of the water heater but that seems wrong.
@LTVoyager
@LTVoyager 5 лет назад
Where is the follow-up video on how to correctly install a Taco circulator. Hint: you NEVER install the electrical box at the bottom side (6 o-clock position) where any water leak can cause a short. The installation instructions make this very clear as does simple common sense.
@MrxDealerz
@MrxDealerz 5 лет назад
@andrew W. I've got the exact same pumps as you, only 2 in the system. The one clearly is spinning and can place your hand on it without burning your hand. The other is clearly not running and the second you place your hand on it to feel for vibration, you've to let go immediately because it's so hot lol.
@MrxDealerz
@MrxDealerz 5 лет назад
The faulty pump is on the return line so explain's why the room doesnt feel like it warming up properly
@jeffrey7636
@jeffrey7636 2 года назад
I really need you help.I’m not sure mine still work or not. It has some noise inside the motor. Also first I trying to bleed water when the heat not working. But unfortunately no water bleed out at all. I have no idea with that. It’s pump stop working cause no water bleed out too?
@estorey1465
@estorey1465 6 лет назад
Where can you buy replacement pumps?
@CitizenPerkins
@CitizenPerkins 3 года назад
At your favorite hardware/lumber store! Just look at their website first.
@TheTarnadog
@TheTarnadog 5 лет назад
how do you make them quiet?
@pasqualeparente9776
@pasqualeparente9776 3 года назад
In my experience, I find that the Grundfos are very quiet and very reliable.
@SirJeep
@SirJeep 2 года назад
Never put the power to the pump at the 6 o'clock position 😤
@larrytate1657
@larrytate1657 5 лет назад
I tackle a lot myself but I think I’m gonna take a pass on this one and call the guy. Good on you though.
@gerardberube1321
@gerardberube1321 3 года назад
His name is Mr Peat , Re Peat
@onemanarmy6073
@onemanarmy6073 3 года назад
Why doesn’t he pronounce the TH sound?
Далее
HOW TO CHANGE A CENTRAL HEATING PUMP - Plumbing Tips
15:46
Remove Air from your Boiler and Heating System | How To
16:25
Symmetrical face⁉️🤔 #beauty
00:15
Просмотров 2,3 млн
Top 10 Circulator Pump Problems Found on Boilers!
20:11
Hydronics System Components
12:31
Просмотров 371 тыс.
How To Change A Water Circulation Pump
20:39
Просмотров 8 тыс.
Replacing a Recirculation Pump
13:48
Просмотров 136 тыс.
How to install a pump in a central heating system
21:25
How To Install a New Boiler Pump
24:00
Просмотров 38 тыс.
How a Zone Valve Works - Hot Water Heating
11:03
Просмотров 348 тыс.
5 most common Boiler Problems 🔥🛠️
9:44
Просмотров 8 тыс.
Forming of goal foam || A2Z SKLLS
1:00
Просмотров 41 млн