Тёмный
No video :(

How to Charge by Superheat With the Fieldpiece Joblink Probes 

TruTech Tools, LTD
Подписаться 16 тыс.
Просмотров 35 тыс.
50% 1

Bert uses the Fieldpiece JobLink probes to charge an older R22 Piston system to the proper Target Superheat quickly and easily. So whether you are wanting to know "The right way to charge an air conditioner with Freon" or you have more refined interest in how to use wet bulb temperature to calculate the target superheat, this video has you covered.

Опубликовано:

 

15 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 70   
@Cougarscream
@Cougarscream 4 года назад
Guys, come on! This video’s purpose is to teach techs how to charge a unit with job link probes... the video’s purpose is NOT to teach proper procedures when dealing with a unit low on charge.
@coldfinger459sub0
@coldfinger459sub0 5 лет назад
Excellent video we need more videos like this to inspire and show the young technicians just coming into the field how to use tools so they’re not intimidated. The only problem My son and I have the Fieldpiece sensor kit and the range sucks (“ unless it’s a simple wooden structure for the signal to go through the walls it does not matter how far sensors will connect in open free air with no obstacles in between at line of sight in the real world we don’t work with in line of sight”!.) in the past several months I use them every day or try to the buildings with brick or concrete walls or just one floor with a concrete floor below you spend more time trying to connect the signal move your phone around or move your senses around if you had to charge by the hour while fiddling with the Fieldpiece software you to go bankrupt first in the real world. But I do like them for simple close proximity jobs I give them a thumbs up in that situation just waiting for them to come out with some better range in depth to penetrate walls in commercial buildings and office buildings. Until then I would wait before purchasing the sensors until they come out with the next generation then I’ll give them a try once again. For those Techs who purchase the Fieldpiece sensors a little word of advice for some reason the Fieldpiece sensors do not always work very well with the Fieldpiece software download the Measure Quick software and that usually fixes fieldpiece sensors problem with connectivity and reliability issues.
@billybbob18
@billybbob18 5 лет назад
Those smans are surprisingly durable. I just bought the sm480v and plan to keep it for a long time. I hope they work out the kinks in the app that others reported last year. Data logging is a must. I was able to connect to the app without issue so far.
@rj.parker
@rj.parker 5 лет назад
Nice work and excellent editing
@MrScatliffe
@MrScatliffe 5 лет назад
Where's the Leak Dude? Are you a tech or an Actor
@_n8787
@_n8787 3 года назад
Read the title you idiot. What it says is exactly what you got.
@scottm3552
@scottm3552 3 года назад
@@_n8787 who are you his fking boyfriend?
@TheGhettoLobster
@TheGhettoLobster 3 года назад
You wanna pay 3 grand for an R22 leak repair or 300 bucks or some gas? lol. Not his choice but the customers dum dum
@productionoperation
@productionoperation 5 лет назад
One thing you might want to add is that You may want to find the source to why the system is low on charge to begin with before adding. Also when we need to charge using super heat with fixed device how important is our sub cool? Next video? Thanks
@michaeldower4335
@michaeldower4335 5 лет назад
Great video and demonstration.
@kevinbennett2565
@kevinbennett2565 4 года назад
@2:55 nice uv light shining through the return grill hahaha. Hope the dog doesn't lay there .
@brianmcdermott1718
@brianmcdermott1718 Год назад
Great video. Bret.👍
@JuanHernandez-vt4wt
@JuanHernandez-vt4wt 5 лет назад
Good video
@jasonreitz6049
@jasonreitz6049 3 года назад
Just a question, if I bought that kit and added a 3rd psychrometer probe to measure the outdoor dry bulb at the condenser, would the app automatically calculate the dry bulb from that probe to calculate target SH, or do you have to enter DB manually like you did? I'm just debating whether to buy the extra psycrometer probe or not... Thanks.
@hernanjoseprietoherrera4839
@hernanjoseprietoherrera4839 2 года назад
Did you get the answer? Let me know. Ty
@416RG
@416RG 2 года назад
I would love to get an answer as well. Did you get that third psychrometer?
@jasonreitz6049
@jasonreitz6049 2 года назад
To map it just go to the probe manager in the toolbox.
@davidmaldonado4849
@davidmaldonado4849 2 года назад
Great job Burt.
@pR3tzeL69
@pR3tzeL69 2 года назад
You make me wanna learn more thank you
@TruTechTools
@TruTechTools 2 года назад
Happy to hear that!
@HVACRNorth
@HVACRNorth 5 лет назад
good video
@anthonynunez164
@anthonynunez164 4 года назад
That bleeding didnt look right lol. That air went right into the system.
@scottm3552
@scottm3552 3 года назад
if the system was off how would air get in the system? looked like the system was off, he purged the hoses after he connected to the refrigerant tank.
@scottm3552
@scottm3552 3 года назад
it actually sounds like the system is running but maybe it was an editing error.
@enduringpromise
@enduringpromise 2 года назад
Thank you,I was wondering if that was correct as I am still learning.
@victorvillafane252
@victorvillafane252 5 лет назад
You’re crazy but do you make so good video thank you sir
@ivansilva4559
@ivansilva4559 3 года назад
Thank you for this video 👍🏻👏🏼👏🏼
@DB-zh3ti
@DB-zh3ti 2 года назад
OBNOXIOUS LOUD MUSIC IS NOT NEEDED. This is suppose to be a video to charge a system. At the start you said the system was low on refrigerant. Hopefully you found the leak and fixed it before charging the system.
@Truthh4040
@Truthh4040 5 лет назад
so if it was r410 a ,,, we only charge it via liqiud ?
@davidberens2189
@davidberens2189 5 лет назад
Yes. Because the r400 series are a mixture and the different components evaporate at different temps. So it needs to be used as a liquid.
@billybbob18
@billybbob18 5 лет назад
Always as a liquid for 410a. Loading as a vapor is as bad as loading the wrong refrigerant(which is technically true).
@mychoclabwinston
@mychoclabwinston 5 лет назад
Wooo Hoo, R22 gone next year,
@rossr4222
@rossr4222 4 года назад
No you find and fix the fucking leak first. Like a real tech would...
@Michael-ig8ne
@Michael-ig8ne 4 года назад
Ross R you understand this is just a video showing how to charge using superheat with this equipment and not a troubleshooting video as to why it’s low on refrigerant, right? Why don’t you chill the fuck out super tech.
@joserodriquez4270
@joserodriquez4270 2 года назад
So, with those probes you don't need gauges..
@BridgeWater94
@BridgeWater94 Год назад
Can I ask why you put your clamp on the liquid line after the dryer? I was always taught 2-3 inches away from the condenser
@kennyjohnson4411
@kennyjohnson4411 2 года назад
Nice video
@rojobandito318
@rojobandito318 3 года назад
Nice werk Bert
@anthonywoo3431
@anthonywoo3431 5 лет назад
Would you guys be able to make a video on the FP probes using My measure quick? Thanks
@HVACS
@HVACS 5 лет назад
Anthony Woo will do! It’s on the list
@greentea111
@greentea111 5 лет назад
dude you are awsome
@victorvillafane252
@victorvillafane252 5 лет назад
Good video bro
@whitesheatingairappliancer7101
Great video thank you.
@daveydave9884
@daveydave9884 3 года назад
Check out that custom flush mount disco
@Stuart68505
@Stuart68505 4 года назад
Was the unit valved off before he purged the lines? It looked like the schraeder valve core was already depressed when he purged the charging hose. If the unit’s pressure was less than the charging tank pressure from say the tank being stored in a hot truck, then the air in the charging hose would have been forced through the open schraeder valve into the unit’s system before he purged the line.
@crunkwizard
@crunkwizard 5 лет назад
Bad ass video
@frankl6684
@frankl6684 5 лет назад
Your comment about the 0 superheat at the evap coil is wrong. The evap coil in flooded at 0 super heat therefore refrigerant is NOT evaporating in the coil. Also the way you were bleeding your charge line is wrong. You should have bled at your bottle with its valve closed. Your line was hooked up to the system that already had charge in it which would have pushed air in the line to the bottle.
@Triaz357
@Triaz357 5 лет назад
The bottles have check valves. You can’t push air into them. Or refrigerant for that matter. And yes a 0 superheat evap coil would be the most efficient, but you would have no protection from the compressor slugging. Just like he said.
@jasonsherrill3518
@jasonsherrill3518 5 лет назад
@@Triaz357 you are missing his point as to why the tank valve should've been closed. Sure, it has a check valve and thus no air or refrigerant can enter the tank. His point was that the valve at the tank should be closed in order to be able to bleed the air out of the lines at the tank. Instead, you tried to bleed air at the unit from the pressure of the open tank. Sadly, this same pressure from the open tank already pushed any air in the lines into the system.
@Triaz357
@Triaz357 5 лет назад
Jason Sherrill That could very well be what he meant but it was not what he said.
@tonymckay9031
@tonymckay9031 5 лет назад
Good stuff 👍 I've recently wanted to learn the difference again between checking suction pipe temp/ superheat at compressor vs evaporator.. with the new probes, it seems more possible to check at evaporator, but why again?
@tonymckay9031
@tonymckay9031 5 лет назад
I suppose at evaporator would just be more accurate statement of what work the evaporators doing. And at the compressor would just be to make sure no liquid comes to the compressor. And then I suppose some manufacturers might specify if they want it at the evaporator or compressor
@HVACS
@HVACS 5 лет назад
Tony McKay just made that tech tip today 😀
@tonymckay9031
@tonymckay9031 5 лет назад
@@HVACS Haha, Thank-you! 👍
@dc1bamf
@dc1bamf 5 лет назад
I have had my set for several months now and love them. They make setting up a Txv a dream with r ed refrigeration equipment. I dont get near the rated distance but they are still a great tool
@donnierobertson3088
@donnierobertson3088 3 года назад
Nice
@techfive7202
@techfive7202 4 года назад
good to know if i ever need to go to outer space when checking charge. Thanks
@HVACRSurvival
@HVACRSurvival 5 лет назад
The way you bled the hose before adding freon didn't look right. Hate to be like everyone else and judge every little dumb thing when you're just trying to prove your point but some viewer's are watching with very little experience. Your valves were open on the system and at the tank when you bled your hose, so any air was already pushed into the system. Good video otherwise👍🏻👍🏻
@jacobharrison1338
@jacobharrison1338 4 года назад
HVACR Survival Maybe the service valve was front seated? With his set up that’s the only way I saw how he could have bled the hose correctly,Or if he did it before he hooked the charging T up.I doubt it since the service valve cap was on.. I’m newish so what I said was probably wrong 😁
@mrcrux213
@mrcrux213 4 года назад
Yes!! he did put noncondensables in to the system but not big deal 😬😳 shit's happened 😎
@cleansebob1
@cleansebob1 3 года назад
No, air didn't go into the system. The system is under pressure, probably at least 50 psi even when off. The air was pushed out of the hose by the refrigerant (and the system if the schrader was depressed), around the male end of the tee / service port, and into the atmosphere.
@BetterMechanical
@BetterMechanical 2 месяца назад
what's with the music?
@carlosjimenez2568
@carlosjimenez2568 3 года назад
Never seen someone charge with the bottle upright.
@rossr4222
@rossr4222 4 года назад
100% the leak is in the evap
@namskramskram6009
@namskramskram6009 Год назад
It's against EPA regulation to add refrigerant to a leaking system... lol
@BillNickerson
@BillNickerson Год назад
Im no tech...and I feel fine.....lol.....
@rossr4222
@rossr4222 4 года назад
Purge air? You completely did that wrong lol. Now you have air in the system
@rossr4222
@rossr4222 4 года назад
Point of being a technician is to find the leak and fix it. Not just add more refrigerant to the system that will leak to atmosphere. Fuck
@juliolara5572
@juliolara5572 4 года назад
Wth......
Далее
Setting a Refrigerant Charge by Subcool
22:43
Просмотров 156 тыс.
до/после Знакомо?
00:16
Просмотров 13 тыс.
NOOOO 😂😂😂
00:14
Просмотров 14 млн
Получили тысячи $$ на "старье".
20:10
HVAC 119 Charging with Wireless Probes
12:54
Просмотров 42 тыс.
Fieldpiece job link probes
11:44
Просмотров 17 тыс.
Four Steps to Flawless Wire Joints (How to Solder)
11:45
How to Use Fieldpiece Wireless Charge and Test Kit
10:48
The Good and Bad of Various HVAC Smart Probes
14:37
Просмотров 11 тыс.
What A Rookie MISTAKE!! | HVAC Life
9:35
Просмотров 207 тыс.
до/после Знакомо?
00:16
Просмотров 13 тыс.