Тёмный

How to check & find Earth fault in DC System | Substation | Power plant 

Nitesh Kumar
Подписаться 70 тыс.
Просмотров 97 тыс.
50% 1

Опубликовано:

 

20 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 230   
@hanumandasji8027
@hanumandasji8027 4 года назад
Thank you for your valuable lecture sir. We are also facing the same problem in our 220kv grid. Now I will try to rectify it.
@manoranjan4598
@manoranjan4598 3 года назад
Sir aapka video bahoot hi achha rhata hai aur banaiye video plz plz
@NiteshKumarElectrical
@NiteshKumarElectrical 3 года назад
Thanks Ji.
@subhashelect
@subhashelect 4 года назад
very Very Importance point for the High voltage Switch Gear
@tusharwilson623
@tusharwilson623 2 года назад
Very nice explanation
@surajparkash1799
@surajparkash1799 Год назад
Good explain with fine way
@vikashkumargarg9453
@vikashkumargarg9453 5 лет назад
Awsame video sir ji
@bartamo3766
@bartamo3766 3 года назад
Sir, suppose there is a damage to few 2volt cells of the battery bank of 110volt battery system of dc supply. Can i remove say six cells and add a 12volt lead acid battery available for home inverter from market and add in series as an emergency. Will it have any consequences?
@bharattiwariwireman2674
@bharattiwariwireman2674 6 лет назад
Sir, Ac supply me bhi earth folt ko isi prakar ham jan sakate hain? Kya yahi process AC me bhi hota hai?
@sharadtiwari755
@sharadtiwari755 3 года назад
Sir Mujhe multimeter purchase karna h..Substation k battery PM k kiye to kaunsa Multimeter lena hai ?
@premasekharramanathan4364
@premasekharramanathan4364 6 лет назад
Thank you very much , please post such practical videos
@umeshsarma53
@umeshsarma53 6 лет назад
Nitesh sir mene apne ghr me mcb 63 amp ka lga rkha tha Havells ka ,or aaj rccb lgaya 40 amp ka Siemens ka, kyunki ghr ka load km h . Jese ki mcb pehle lgta h or uske baad me rccb thik vese connection jb kiye to rccb ekdum trip ho ja rha h jese hi me koi fan load ya refrigerator load on krta hu ...Lekin jb mcb. (63amp. D.P.) ko rccb k baad lgaya to rccb normal work kr rha h ...ab mujhe ye btaaye ki ye connection shi ese hi rehne de ya fir rccb(40amp.) mcb (63amp. D.P) k baad lgaye. And Jo mcb single pole k lge h vo 10 amp or 16 amp k h lekin jb me wire daal k socket se short kia to mcb trip hi nhi hota blki socket burn hone lg gyi. Plz suggest me some good idea
@bilalzinda3541
@bilalzinda3541 6 лет назад
helo brother kya hal hay ye pochna tha k ht volt kitni dori say noqsan karty hay matlab kitny volt par kitni dori say ap kam kar sakty plz reply kijey GA thanx
@khan_tanzeem0521
@khan_tanzeem0521 2 года назад
So in the case above are we further going to trace the positive earth fault identified or look for loose connection at the MCB for rectification please explain? (Enjoyed watching your video)
@ameerkolambalam2670
@ameerkolambalam2670 2 года назад
Sir iam diploma apprenticeship in pgcl and wait for next video
@sumittiwari327
@sumittiwari327 4 года назад
Sir kya multimeter se DB panel ki earthing check Kar Sakte hai? Uspar ek vedio bna dijiye
@erajay2010
@erajay2010 4 года назад
Sir please btaiye kya shut down liye bina hum particular section ko one by one isolate kr ke means uska ckt disconnect kr ke (DCDB se) dc leakage test kr skte h
@NiteshKumarElectrical
@NiteshKumarElectrical 4 года назад
SOP ke anusar to shutdown lena hi chahiye. Bina shutdown ka koi bhi allow nahi karega aisa karne ke liye.
@ashoksinghbhati87
@ashoksinghbhati87 6 лет назад
Very nice concept sir. Please carry on. Thank you
@mix_videos_islamic_knowled4804
@mix_videos_islamic_knowled4804 3 года назад
Nice info
@uddipansarkar90
@uddipansarkar90 6 лет назад
Nitesh ji agar earth fault nahi hota toh +ve to gnd and -ve to gnd kitna voltage ana chahiye tha??
@shyara_parth
@shyara_parth 6 лет назад
hello.sir.agar positive and negative dono me EF nahi hoto to dono k bich me kitana voltage show karega?...
@amitkumar-im3ji
@amitkumar-im3ji 5 лет назад
Sir i am diploma trainee in pgcil....and learning a lot from ur videos..thank u so much for uploading such videos.... please keep giving new videos and more information....😊 Want ur reply also.......
@NiteshKumarElectrical
@NiteshKumarElectrical 5 лет назад
Thanks for learning from my Videos Amit !👍 That's great !! PGCIL is a one of the best Organization to Work for electrical engineer. Keep on learning and serving Country !👍 I will be replying. Thanks 👍
@amitkumar-im3ji
@amitkumar-im3ji 5 лет назад
@@NiteshKumarElectrical sir really excited to know more about master trip relay and how it works... can u make a video over it....pls....
@NiteshKumarElectrical
@NiteshKumarElectrical 5 лет назад
Ok I will make.
@soumyaranjanmohanty9431
@soumyaranjanmohanty9431 6 лет назад
DEAR SIR , Let me introduce my self as a protection engineer ,working for Schneider electric. Sir I got from your video that how I can know whether it is a +ve or -ve DC earth fault. As DCDB provide DC voltage to all required ckt(i.e C&R panels, CB ckt.) . So how can I easily trace out that particular ckt. where the earth fault occur so that I can make my system normal?
@NiteshKumarElectrical
@NiteshKumarElectrical 6 лет назад
Thanks Mr.Sumya ! I am happy that you learnt from my videos ! keep it up ! all the best for your technical enhancement ;)
@rajkishan1799
@rajkishan1799 5 лет назад
Bhai koi vacancy hai kya
@sadaqatali9166
@sadaqatali9166 2 года назад
If you have answer plz share with me
@surendrakverma555
@surendrakverma555 3 года назад
Very good
@yogeshkumar8659
@yogeshkumar8659 6 лет назад
Awesome way of practical
@punamchand4059
@punamchand4059 6 лет назад
बहुत-बहुत धन्यवाद
@sajidabbas73
@sajidabbas73 2 года назад
sir one q. what is panel waring
@zakirulislam-i3f
@zakirulislam-i3f 7 месяцев назад
what is the procedure to solve the +ground fault? if u have any video plz give me the link
@mdmanzarali9117
@mdmanzarali9117 6 лет назад
Very smart explanation
@smrutijitsatapathy7317
@smrutijitsatapathy7317 6 лет назад
Super class sirji
@darwint4065
@darwint4065 2 года назад
Good potential value positive to earth ? Negetive to earth ?
@pankajbehera8461
@pankajbehera8461 6 лет назад
Sir Us wire ground Kahan hua hai kese pata chalega I mean us mcb Ko kholenge ya kuch aur method hai
@DeadSr851
@DeadSr851 4 года назад
Well guidance thank you
@DevD1111
@DevD1111 6 лет назад
Hello sir- very informative video. Ek acchi grounding k liye neutral and ground k bich m kitna voltage hona chaiye.
@raytech6049
@raytech6049 2 года назад
We do service all these digital meters in Kolkata with best accuracy 👌 .
@harathireddyk2210
@harathireddyk2210 5 лет назад
Sir... How to check yard light system in 66/11KV sub station is properly earthed or not
@NiteshKumarElectrical
@NiteshKumarElectrical 5 лет назад
1. Light - Check all the concerned ckt. 2. Earthing :- You need to test Earth resistance of earth pit using ERT meter. If value is ok then earthling is good.
@ersachinsaini2064
@ersachinsaini2064 4 года назад
Ab earth fault ko trace kaise karoge jabki cable to sab jagah ja rhi ho underground and through chanel or congested area .....that u know what I am asking... Plss reply
@NiteshKumarElectrical
@NiteshKumarElectrical 4 года назад
Video me maine bataya hai na trace karne k liye. Alag alag circuit ko pahle identity karo ki kis me hai. Uske bad trace hoga scheme ke according.
@ShubhamYadav-mu6go
@ShubhamYadav-mu6go 6 лет назад
thank u sir. sir power factor ko lekar bahut confusion h iske baare Me detail se bataiye plz.
@shivkumarchaturvedi5619
@shivkumarchaturvedi5619 4 года назад
Please explain why 50% potential found wrt. Ground in isolated dc control supply system
@DeepakMishra-js8ed
@DeepakMishra-js8ed 6 лет назад
u r superb sir
@erajay2010
@erajay2010 4 года назад
Sir can I connect Galvanometer with the dc Circuit to check dc leakage? So that if there is any leakage, Galvanometer must deflect.
@NiteshKumarElectrical
@NiteshKumarElectrical 4 года назад
Galvanometer work on AC ...If I am not wrong. ! 😊
@alamzeb6342
@alamzeb6342 6 лет назад
Dear its been great effort you made, we really appreciate your this effort.
@vinaykushwaha2380
@vinaykushwaha2380 5 лет назад
Too much good explanation bhai
@RamaKrishnan-hx4ui
@RamaKrishnan-hx4ui 4 года назад
Sir mujhe ek bat samaj nahi aya wt r the advantage to ground the +ve , if the +ve shorted to the earth how can we getting the voltage.
@sanambuet2721
@sanambuet2721 6 лет назад
Nitesh brother, can you please provide the video on protection scheme design which you explained earlier but now i can't find them. please
@ZahidHussain-wk1zl
@ZahidHussain-wk1zl 6 лет назад
How do I test a transformer differential relay slope, high sets? Please explain..
@ketankhairnar3320
@ketankhairnar3320 6 лет назад
Nice dar
@er.pratiksingh8339
@er.pratiksingh8339 5 лет назад
Sir please reply karna Mera job laga hi Estimation engineer me join krna chaiye kya FUTURE kaisa rahega Company panel manufacturing company hi please reply
@NiteshKumarElectrical
@NiteshKumarElectrical 5 лет назад
Kaha laga hi aur job role kya hi ??
@arpengoyal3051
@arpengoyal3051 6 лет назад
Bhai..substation me jitne b equipments hote h unki selection kse krte h??? oske upper koi video bna do..plxZzz bhai
@sagartrivedi7168
@sagartrivedi7168 4 года назад
Sir ager positive or negative dono me earth fault ho to?
@khareshkumar21
@khareshkumar21 3 года назад
Thank you sir
@AmitThakur-yl9kr
@AmitThakur-yl9kr 6 лет назад
Thanks for your explanation...
@adithihomeplant3661
@adithihomeplant3661 4 года назад
We r switch one by one feeder dc supply .but it's fault in battery charger how to check fault sir.
@pratikbhatt95
@pratikbhatt95 5 лет назад
Nice bro... I saw many of your videos, u have good knowledge and also u can explain very well. Best wishes, keep making more and more videos, our youth needs confusion free knowledge as u giving...👍
@nhattru3195
@nhattru3195 5 лет назад
Thank sir, I have question, At power house, DC system display fault: Battery Earth Fault, How do check faul? Thank you!
@NiteshKumarElectrical
@NiteshKumarElectrical 5 лет назад
Watch this Video. I have uploaded today to answer your questions. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-auwNwBGX744.html This is in English language. If you want to watch in Hindi then link is given in the description box of this video. Or search in my channel. Thanks.
@dharmedradharuka9540
@dharmedradharuka9540 5 лет назад
Good thank you sir
@VIKRAMSINGH-eo1lo
@VIKRAMSINGH-eo1lo 3 года назад
If there is a minor difference between positive - Earth and negative Earth voltage then DC is leakage anywhere or not.If leakage then how we find out at which point DC Leakage and we can short it.Plz explain..
@NiteshKumarElectrical
@NiteshKumarElectrical 3 года назад
You would have got some idea by watching this video. Concept is same only. However I will explain in a separate video about your concern. Thanks.
@aamirawan7998
@aamirawan7998 3 года назад
What if there was no ground fault? What will be the voltage then between positive and ground and also negative and ground?
@ajayrai129
@ajayrai129 3 года назад
Please provide information regarding what voltage values will be obtained when there is no earth fault..
@satnam7namsingh158
@satnam7namsingh158 5 лет назад
Good video
@manojshukla3598
@manojshukla3598 6 лет назад
sir provide any source for understanding relay setting of Siemens ,abb ,and easun relay as well as motor protections
@csgupta7017
@csgupta7017 3 года назад
In some cases either positive or negative is grounded . If positive is grounded then how can we detect earth fault between negative and earth?
@BPS666
@BPS666 4 года назад
How to troubleshoot the tripping device burn out in breaker?
@iswarmahanta6905
@iswarmahanta6905 5 лет назад
Why 220 v dc supply half between ph to ground..? Please sir fundamental clear...?
@nerldcshillong2272
@nerldcshillong2272 5 лет назад
Can you please give me the value of capacitance of dc positive to Earth or negative to Earth (of your substation)
@shashanksinha2593
@shashanksinha2593 6 лет назад
It's helpful for me thks...
@erajaykumarv8755
@erajaykumarv8755 6 лет назад
Thank you for your information
@satyarout9377
@satyarout9377 5 лет назад
Sir healthy conditions main kyun voltage half show kar ta hai meter
@dipanjandas9463
@dipanjandas9463 6 лет назад
Thank you sir. After identify how to solve this earth fault. 1Q. What is float charging & Boost charging and for 10 KW dc motor what capacity of battery bank required? Please explain.
@dinabandhukhuntia9077
@dinabandhukhuntia9077 2 года назад
How we get voltage reference to earth where battery is not grounded.you only get voltage from +ve to- ve value. So you must describe the middile point earhing first.
@boloharekesaharekejaijai4003
@boloharekesaharekejaijai4003 6 лет назад
You are great Sir
@parthaproteemroy9742
@parthaproteemroy9742 6 лет назад
I want to know what about Telecom Systems where we need negative voltage where the positive is grounded in order to give negative voltage to the systems
@sadaqatali9166
@sadaqatali9166 Год назад
Kumar sb substaion mea kisey dohanday k exect kha earth ho rahae ha sir
@himanshurana2181
@himanshurana2181 6 лет назад
Than you sir for this help
@satheeshkumar3977
@satheeshkumar3977 6 лет назад
Good
@solarinstallationsbyaman7252
@solarinstallationsbyaman7252 3 года назад
good
@LifEoFaSaiLor2022
@LifEoFaSaiLor2022 5 лет назад
EARTH FAULT NI HOTA HAI TOH POSITIVE AND GND AND NEGETIVE AND GND K BICH KITNA HOTA HAI?HEALTHY CONDITION ME I MEAN
@asifkhokhar9331
@asifkhokhar9331 4 года назад
Thank you
@mohammednazeeruddin5931
@mohammednazeeruddin5931 6 лет назад
How to trace and rectify this ground fault?
@kanimran9285
@kanimran9285 6 лет назад
Good explain. ......
@sadaqatali9166
@sadaqatali9166 2 года назад
How i find DC lekeage in grid station system
@ervijay668
@ervijay668 3 года назад
Battery bank ki +ve kyu ground ki jati hai ?
@anoopverma3912
@anoopverma3912 6 лет назад
Nice sir
@sanjeevreddy4811
@sanjeevreddy4811 6 лет назад
Bihar ka Sher...
@NiteshKumarElectrical
@NiteshKumarElectrical 6 лет назад
Thank You SANJEEV. ;)
@aurobindamohapatra2768
@aurobindamohapatra2768 6 лет назад
Sir thank you, sir ekk ratings ke bare me ekk video banao
@sadaqatali9166
@sadaqatali9166 2 года назад
How we find exect location of DC grounding
@asthalalakimasti1989
@asthalalakimasti1989 6 лет назад
Dear sr Positive aur negative me 220 v dikhata hai lekin positive me earth se +110 v dikhata hai neg me -110v dikha hai aisa kyo kyo nhi +220 aur - 0 dikhata
@mdmanzarali9117
@mdmanzarali9117 6 лет назад
Pls make one video on oil filtration of transformer
@mdnadeemhussainansari6770
@mdnadeemhussainansari6770 6 лет назад
nice sir
@mohammednazeeruddin5931
@mohammednazeeruddin5931 6 лет назад
If both positive & negative are grounded then what multimeter will show ??
@rjshtk
@rjshtk 5 лет назад
That s tricky. it might even cancel out showing 0 leakage (on a milli ammeter meant for that). But still with a multimeter, you can check the voltage between + and earth and then the voltage between - and earth and see if they are in equal in magnitude. if they are, no leakage. if the values are nt half of the dc system voltage, then there is leakage (lower voltage than half of the system dc voltage)
@rajvaghadiya8814
@rajvaghadiya8814 5 лет назад
How Will you prevent it please tell
@d.kkumar4186
@d.kkumar4186 5 лет назад
Aap konse plant me ho ji
@NiteshKumarElectrical
@NiteshKumarElectrical 5 лет назад
Substation me ji.
@Devendrakumarpankaj
@Devendrakumarpankaj 2 месяца назад
Thanks
@alienvaigyanik5470
@alienvaigyanik5470 Год назад
Sunder
@yogeshkumar8659
@yogeshkumar8659 6 лет назад
How I can troubleshoot this. Dear sir, in my sub station Positive DC ground... Plz sir provide some answers
@NiteshKumarElectrical
@NiteshKumarElectrical 6 лет назад
Switch off one by one ckt and check the positive with respect to ground. If you get 110V +Ve then the problem is there in that particular ckt. For an example:- if you switch off Isolator control ckt as per drawing and then check. One by one. CB closing ckt. For each and every ckt. There will be a particular MCB.
@uuuu2843
@uuuu2843 5 лет назад
Thank you bro
@mukeshghodakiya8839
@mukeshghodakiya8839 6 лет назад
mere substation ke battery charger me earthlikage ka indications aa Gaya hai. kese find out karna padega sir?
@s.pmohanty981
@s.pmohanty981 2 года назад
Aagar BEFR nehi hoga to kese pata chalega dc earth fault he.dc earth fault honese kya problem aayaga jeseki haam pata kar sakte he ki dc fault he.
@a.kkumar8029
@a.kkumar8029 4 года назад
Scada system pe logset kese nikalnge sir
@lalitpseb
@lalitpseb 6 лет назад
Sir hamare substation me flot me dc 240-235 rehti hai.but boost ke time 190 rah jati hai. why it serious matter?
@rjshtk
@rjshtk 5 лет назад
Check your pot setting / voltage out setting for boost mode
@SimajNewsonline8626
@SimajNewsonline8626 6 лет назад
Nice
Далее
Тестирую гаджет для роллов! 🙈
00:42
FIXING 24 VOLTS LOW INSULATION | Marine Electrician
9:40
24VOLTS EARTH FAULT BURNT 2 POWER SUPPLIES
10:30
Просмотров 24 тыс.
Тестирую гаджет для роллов! 🙈
00:42