Тёмный

How to conduct forced degradation study? 

Pharma Growth Hub
Подписаться 29 тыс.
Просмотров 20 тыс.
50% 1

ICH guidelines emphasize the importance of conducting forced degradation studies, but provided only very general and limited information on the experimental stress conditions. This video will help you to understand forced degradation to much deeper level.

Опубликовано:

 

22 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 34   
@hanumantgare1891
@hanumantgare1891 2 года назад
Very nice presentation and explain in very easy language. Thanku so much sir for your efforts.
@rohinikumar7065
@rohinikumar7065 3 года назад
Nice presentation sir and make video on what are facts effecting mass balance failure and solutions
@prashantpandit7806
@prashantpandit7806 2 года назад
Superbly Explained...👍🏻
@manishkharkwal6106
@manishkharkwal6106 2 года назад
Ur presentation was good. Please check as for evaluating purity / spectra in FD, PDA detectors required not UV. But overall content was good. Thanks for sharing
@mrinmoysarkar4133
@mrinmoysarkar4133 2 года назад
Thanks a lot sir...it's really informative ♥️♥️🙏🙏
@mitalipereira446
@mitalipereira446 3 года назад
Sir, Please make video on finding LOD and LOQ of method
@rajeshpudi8795
@rajeshpudi8795 2 года назад
Linearity and sample concentration chapter available
@modernmogli5155
@modernmogli5155 3 года назад
Sir what software is this you are using , its very nice way to explain
@rahulgunjal663
@rahulgunjal663 3 года назад
Sir kindly make video on mass balance calculation in fd
@krish_krish354
@krish_krish354 3 года назад
If the compound melting point or boiling point near 45 degree can we conduct acid or base hydrolysis at 80 c
@PG12333
@PG12333 3 года назад
What is mass balance in FD study and how it is calculate
@LearnValue
@LearnValue Год назад
Plus or minus 5% is acceptable
@kishordangat684
@kishordangat684 2 года назад
Good presentation
@sameer_shindeshinde3674
@sameer_shindeshinde3674 2 года назад
Ur content is good so don't show advertising in between video, it disturb during learning.....
@krish_krish354
@krish_krish354 2 года назад
For themal degradation dry method sample alone heated. For wet method with sampl wt will be added
@jnaniashok
@jnaniashok Год назад
Excellent..
@pankajshah1084
@pankajshah1084 3 года назад
Nice video sir, very useful
@ankushthakur213
@ankushthakur213 Месяц назад
Stability indicating method meaning?
@madhavikatta2150
@madhavikatta2150 2 года назад
Well explained sir thank you 😊
@rahulchadha6795
@rahulchadha6795 Год назад
Is it possible to do FD on UV methods?
@mohdazeemuddin8353
@mohdazeemuddin8353 Год назад
Hi sir This is Azeem My Question is We have controlled Nitrite content in water NMT 0.03ppm Secondary amine is there Nitrosamine is possible pls suggest Provide the guideline
@rohitkhade4060
@rohitkhade4060 3 года назад
How to perform normal phase force degradation study
@krish_krish354
@krish_krish354 3 года назад
While conducting acid hydrolysis sample with hcl added. With this diluent added and kept in oven for degradation. Diluent added means how much should add before keeping in oven for hydrolysis. Can anyone reply please
@pharmagrowthhub3083
@pharmagrowthhub3083 3 года назад
The volume of diluent should be sufficient to solubalize your analyte before you proceed degradation
@krish_krish354
@krish_krish354 3 года назад
@@pharmagrowthhub3083 if suppose sample and HCl only added no other diluent added before keeping in oven. after taken out from oven neutralize with NaOH and make up with diluent. This way of doing foreced degradation right or wrong.
@verans7152
@verans7152 Год назад
Thanks sir
@sanketdalvi2942
@sanketdalvi2942 2 года назад
Thanks sir....,❤️
@krish_krish354
@krish_krish354 3 года назад
Degradation 5_20 or 5_30 in other video of yours I saw 5_30 which is correct
@pharmagrowthhub3083
@pharmagrowthhub3083 3 года назад
5-20% is more relevant and accurate, though there is no as such regulatory reference available.
@krish_krish354
@krish_krish354 3 года назад
@@pharmagrowthhub3083 thank you
@krish_krish354
@krish_krish354 3 года назад
@@pharmagrowthhub3083 what are regulatory guidelines using for a method validation. Not only ICHQ2R1 and R2. Other than
@PG12333
@PG12333 3 года назад
Sir please make videos on process validation
@supriyabhamare06
@supriyabhamare06 Год назад
How to select drugs for FDS study
@ShikshanAcademy
@ShikshanAcademy Год назад
Pls put pdf
Далее
3 common interview questions on Forced Degradation
21:14
How to establish MACO Value during cleaning validation
26:19
Paint Projects
00:17
Просмотров 4,5 млн
Causes of peak splitting in HPLC and ways to fix it
16:24
Basic terms in stability study
25:47
Просмотров 9 тыс.
why conduct forced degradation?
16:12
Просмотров 4,8 тыс.