Welcome to this comprehensive guide on how to configure OPC UA server in Siemens PLC. Specially designed for engineers and automation experts, this tutorial will take you through all the necessary steps needed to set up OPC UA server in Siemens PLC.
OPC UA, which stands for Open Platform Communications Unified Architecture, is an industry-standard communication protocol that helps devices from different manufacturers communicate seamlessly with one another. OPC UA servers enable the exchange of data between devices and applications, simplifying automation workflows.
The first step to setting up OPC UA server on your Siemens PLC is to ensure that you have the necessary hardware and software. You will need a Siemens Controller, Simatic STEP 7, and OPC UA Server License.
Next, open the project that you want to configure. Navigate to the "Device Configuration" menu and select the S7-1500 CPU. Click on the "Properties" button and choose "OPC UA Server" from the "Communication" tab.
Now, select the "OPC UA Server Parameters" menu and enter relevant information, such as the server name, application URI, and security settings. It is crucial to identify the correct port for the OPC UA server to prevent communication breakdowns and security breaches.
After setting up the OPC UA server parameters, it’s time to configure the security settings. Assign security permissions to the OPC UA server using the "User Management" function, which is accessible through the "OPC UA Server Parameters."
Then, activate the OPC UA server on your Siemens PLC by clicking on the "Enable OPC UA Server" button. This step ensures that the server is properly configured and can exchange data with other OPC UA servers.
Finally, test the functionality of the OPC UA server by using an OPC UA client, such as the UA Expert software. Connect the OPC UA client to the OPC UA server using the IP address and port number of the Siemens PLC. If the connection is successful, you should be able to read and write variables and signals on your Siemens PLC.
In conclusion, setting up OPC UA server in Siemens PLC is a straightforward process that requires a knowledge of the right steps and procedures. Following this guide will help you streamline automation workflows and improve communication between devices and applications. Do well to leave a comment telling us how this guide has helped with your application.
My Website : tarkguru.com/
My Linked In : / automationbysaumilpatel
My App : Automation By Saumil Patel : lnkd.in/dDWNQrc3
For IPhone users: lnkd.in/d8dxakiA
and enter the code: acibj
#industrialautomation #automation #plctraining #siemens #tiaportal #siemensplctraining #opcua #s71500 #s71200 #iiot

Опубликовано:

 

30 апр 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии    
Далее
Советы на всё лето 4 @postworkllc
00:23
ELA NÃO ESPERAVA POR ISSO 🥶 ATTITUDE #shorts
00:20
How does Modbus Communication Protocol Work?
11:53
Просмотров 520 тыс.
What is OPC UA |How it works ? Tutorial for Beginners
10:02
OPC UA Lesson 1- What is OPC UA?
12:52
Просмотров 131 тыс.
eBPF: Unlocking the Kernel [OFFICIAL DOCUMENTARY]
30:00
OPC UA with Visual Studio and C#
50:10
Просмотров 45 тыс.