Consistency test, initial setting test and final setting test of cement,,,, How to do consistency test of cement || cement ki consistency test kaise karein
Mold ko properly fill krna h, aap without temping rod ke bhi kr sakte ho bs yhi h ki cement past mold me achhe se fill hona chahiye, temping rod ka size 16mm dia, 600 mm length
@@ShravankumarGupta-ol9ns lekin ek baat samajh nahi aaya apne pahle se hi kaise decide kar liya 31% water consistency hai. vo toh nikalna padta hai random percentage of water dalke and jis water content me 10mm needle 5-7mm penetrate karega wohi uss cement ka consistency value hoga
Alag alag cement weight ke hisab se water 25-35% tk rkha jata but standard as per IS code agar aap 300 g cement le rhe ho toh aapko eska 31% water rkhna hoga
Is code me asa kanhi pe likha ni hai 25-35% rakhna hai, humko check krna hota h alag alag % me water lekar check kia jata hai..... jis water % me 5 se 7 mm ke bich aa rha hai vo cement ka consistency hota hai