Тёмный

How to Install 3” PVC Megalug joint restraints 

Faustino Gonzalez
Подписаться 71
Просмотров 19 тыс.
50% 1

Опубликовано:

 

20 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 21   
@fredgonzales9313
@fredgonzales9313 2 года назад
This is bad ass bro I didn’t realize you posted it
@faustinogonzalez9856
@faustinogonzalez9856 2 года назад
Appreciate it! Somebody had to lol jp
@kiljoysvnzr0
@kiljoysvnzr0 Год назад
Wouldn't hurt to cut off the bevel on that end but other than that, that is how you do it.
@alphawhisky1683
@alphawhisky1683 Год назад
Cool seeing how different places are. Here we could use blue with dr28 type pipe. Either all blue or DI. An no up a down in the pipe like that to much chance for air pockets during testing would take forever. Hard to tell in video how grade is running also but here bell end on the uphill. Cool video tho glad to see ppl doing there thing.
@johngluck895
@johngluck895 3 года назад
Great job Tino
@faustinogonzalez9856
@faustinogonzalez9856 2 года назад
Thank you sir!
@mikejohnson3601
@mikejohnson3601 2 года назад
A torque wrench works best
@WadeConstructionServicesGroup
@WadeConstructionServicesGroup 10 месяцев назад
Question. What do you charge per foot to install a 4" water line? If the customer provides material and you trench and install the line. I'm in Texas and I'm trying to compare pricing.
@UKsystems
@UKsystems 10 месяцев назад
If you do all that why dot do all
@bijaytamang1268
@bijaytamang1268 3 года назад
Nice video!
@faustinogonzalez9856
@faustinogonzalez9856 2 года назад
Thanks!
@flatsfishin
@flatsfishin 2 года назад
Nice work. What tq are you tightening those bolts to w that impact..? Do you guys use pipe lube?
@rongray4118
@rongray4118 7 месяцев назад
Manufacturers specification (normal 65ft.lbs. to 110ft.lbs dependent upon pipe diameter).
@munozjose7974
@munozjose7974 2 года назад
Es mi trabajo me gusta este trabajo
@thomasdougless6855
@thomasdougless6855 Год назад
Zinc caps?
@OscarRamirez-wi5bx
@OscarRamirez-wi5bx 2 года назад
What state is this in???
@mikejohnson3601
@mikejohnson3601 2 года назад
I thought regular pvc pipes could not use with type of restraint
@flatsfishin
@flatsfishin 2 года назад
I work with these pretty frequently doing mainline irrigation repairs up to about 12”. Believe theres a section of 24” at this place I work but doubt we’ll need to repair it. You can absolutely use them with PVC, they’re great for the high pressure systems especially repairs where it can be tight instead of installs where the trenches are wide open
@kiljoysvnzr0
@kiljoysvnzr0 Год назад
These are designed for C-900 ( water main pipe), but you don't want to use the ones designed for ductile iron on C-900 and visa-versa.
@ramonvillalobos1018
@ramonvillalobos1018 11 месяцев назад
we cut the beveled end off
@sergioblas9427
@sergioblas9427 Год назад
Mal desde que empezó no sabes instalar pvc c-900 .
Далее
Proper Pipe Installation
7:44
Просмотров 19 тыс.
Rev 1 4000G2 Install
16:41
Просмотров 6 тыс.
Кольцо Всевластия от Samsung
01:00
Просмотров 196 тыс.
How to Install Mechanical Joint Pipe and Fittings
3:33
Laying 8" C900 waterline, closeup of the crew tasks
6:08
The Motorcycle That Will Change Travel Forever
32:53
Просмотров 2,7 млн
PVC C900 (2 DE 5)
3:49
Просмотров 46 тыс.
54" Installation
3:10
Просмотров 203 тыс.
Connecting to PVC using an MJ Adapter
2:26
Просмотров 29 тыс.
Why Pipes Move Underground
12:03
Просмотров 2,2 млн
Hot Tapping Water main
4:04
Просмотров 106 тыс.
Кольцо Всевластия от Samsung
01:00
Просмотров 196 тыс.