Тёмный

How to Install a 3000 watt Inverter in a Caravan Part 2 

Muddy and Sandy
Подписаться 857
Просмотров 21 тыс.
50% 1

How to wire a 3000 watt renogy inverter into a caravan part 2, renogy inverter converts 12 volt supply to 240 volt supply to run your appliances inside your off-road caravan when your off grid.
SUBSCRIBE HERE------ www.youtube.co...
#inverter
#inverter12vto220v
#inverterbattery
#inverters
#instagraminverters
#renogyinverter
#renogy #3000wattinverter
#offgrid
#caravan #4x4 #4x4adventure #offgridcamping #offroadcaravan #supremecaravans #supremecaravans #supremeoffroadcaravan #poweroffgrid #12voltbatterycharger #12voltinverter #12voltgrid #renogygear #renogyinverter #offgridliving #happy #happybirthday

Опубликовано:

 

13 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 59   
@jonathanhughes6153
@jonathanhughes6153 3 дня назад
Good job mate, I like the little current/voltage module in the DB. Did you link out the earth and neutral from the inverter at the DB? Otherwise wouldn’t you be getting roughly 110V between N-E and A-E, and only 110/120V at all outlets and appliances?
@muddyandsandy
@muddyandsandy 3 дня назад
I have the earth from inverter to switchboard ...wired into the other earth's....the neutral from the inverter go straight into change over switch with inverter active....change over switch separates 240v input plug on side of van from inverter input....
@seanhoward9604
@seanhoward9604 10 месяцев назад
Best video ive seen on this stuff in a while cheers
@muddyandsandy
@muddyandsandy 10 месяцев назад
Thank you...appreciate that....
@pasgw1
@pasgw1 Год назад
Hi, for your HWS, Fridge & Charger I would put remote controlled power outlets on them. Bunnings sell an Arlec version. Then just fit the remote somewhere easy to see. One remote can control 4 outlets. That way they are always OFF, just when you plug into grid power you push the remote and they all come on.
@muddyandsandy
@muddyandsandy Год назад
Not a bad ideal..I'll look into it....thanks for your comment
@coreyshwereb5839
@coreyshwereb5839 10 месяцев назад
Hey mate im going to run that same electrical for my inverter can you tell me the name of it. Im going to run all the wires for the sparky. Also what amp change over switch it required? Cheers
@ooshie9293
@ooshie9293 Год назад
Great video, thanks. You make it look easy!
@muddyandsandy
@muddyandsandy Год назад
Thanks....it's not to hard to do...just double check everything before you do anything...saved alot by doing it myself...thanks for the comment
@MrOldref
@MrOldref 2 месяца назад
The RCD will not trip on inverter, a Residual Voltage Device such as an RCD DUO will have to replace the RCD. Works on a rise of 40 volts on the earth.
@muddyandsandy
@muddyandsandy 2 месяца назад
I'll check it out...
@hemz8058
@hemz8058 18 дней назад
Hey mate, Im trying to do a similar thing to you and i was just curious on a couple of things: - why do you manually switch the power from mains to inverter? Doesnt your renogy have a passthrough mode which auto detects and switches when shore power is detected? - how come you left the bandaid fix of turning off the charger instead of running that single GPO through the battery?
@muddyandsandy
@muddyandsandy 18 дней назад
Hey mate, I believe the renogy does have a pass through, I don't use it that offen sometimes when off grid..so don't need it to pass through, just turn on when I want it...I think the lifespan of the inverter would last longer if the Electronics /heating terminals aren't running consistently when I'm using 240v....not sure what you mean by putting the single GPO on battery, that GPO for charger is only 240v, not for inverter. Not sure what you mean
@hemz8058
@hemz8058 18 дней назад
@@muddyandsandy I see, thanks. I'm still learning a lot about all this 12v stuff so probably didn't articulate myself very well. As far as passthrough works, it bought it turned the inverter off when it senses shore power, but activates it when shore power ceases. With the charger PowerPoint, is that purely for shore power to charge the batteries? So does that mean you could have that GPO not patched through the inverter but standalone through shore power? Or am I interpreting its function wrong? Also, will you put your lithium batteries under the bed space sealed and vent them outside?
@muddyandsandy
@muddyandsandy 15 дней назад
@hemz8058 all good...I have wired they whole van off the inverter, eg. Inverter output straight to switchboard with change over cicruit breaker,that's why I turn off the GPO for the charger, if you don't then power goes around in circles....eg....from inverter to GPO charger to battery's out of battery's to inverter to GPO charger etc.....that's pointless...so i just turn it off, easy to do..
@michaelmckenzie7616
@michaelmckenzie7616 Год назад
Great vid. I look foward to part 3. When will it be available?
@muddyandsandy
@muddyandsandy Год назад
Yes...I'll do a update
@cyclemoto8744
@cyclemoto8744 5 месяцев назад
Thanks for sharing. Cheers. Ps: Did I imagine it or did I actually see a RedVision system? If so, maybe you should have spent the money on LifePo4 batteries instead of the Redarc unit
@muddyandsandy
@muddyandsandy 5 месяцев назад
Redarc system come with the van, when I purchased it, the next step was to upgrade batterys
@cyclemoto8744
@cyclemoto8744 5 месяцев назад
@@muddyandsandy Based on the various brands which I a saw in your video, that makes sense. Cheers
@jtagg3
@jtagg3 7 месяцев назад
can you run the fridge on 12v with the inverter on? I only plan on using 240 for cooking woth an induction top and hot water, after that would switch back to 12v to save on using gas
@muddyandsandy
@muddyandsandy 7 месяцев назад
That's a hard one..because the fridge I use is a 3 way....which uses around 20+amps on 12v....that's alot...easier to run on gas....unless you have a compressor fridge that would be fine, but it would need a lithium setup......I only use inverter for 240v appliances...blenders,toaster etc
@tyrongower
@tyrongower Год назад
Does rhe rcbo work with the inverter correctly? Guessing it does not internally bond neutral and ground?
@muddyandsandy
@muddyandsandy Год назад
Hey...yes the rcbo works..it's grounded Internally...floating earth I think they call it...
@78leppy
@78leppy 5 месяцев назад
Rcd wont trip unless you've bonded neutral and ground ......the test button will trip it but not an rcd tester
@camo103
@camo103 Год назад
Good informative vid mate One question when this is all working will the shore supply plug (the 15amp from the mains to the caravan) be alive?
@muddyandsandy
@muddyandsandy Год назад
Hey....no it doesnt...as I have a change over switch, which disconnects from that plug....and connects to just the inverter input and power points in van....think of it like this....the change over switch has two inputs and one output...the 2 inputs are totally separate from each other....you can switch up for example for shore power or down for inverter power...thanks for the comment
@camo103
@camo103 Год назад
@@muddyandsandy awesome I want to do my own (not an electrician) so I’ll research change over switches Thanks for the reply 👍
@gandalf2256
@gandalf2256 10 месяцев назад
The renogy inverter does the changeover itself
@richardsaunders5547
@richardsaunders5547 9 месяцев назад
Where to start!? Jeez love it, soooo I have a caravan with 12 volt everything too as stock and an electric hookup plug on the outside. I was thinking of … setting the leisure battery (460Ah lithium phosphate) in my boot and connecting it too the same 3000 watt Renogy inverter. Outputting from the inverter into the caravans electric hookup, would that work? Again I’d run the fridge and heating off of gas. It would mean the 240 sockets would all be active then for microwave and kettle etc. any issues with running the inverter for extended time periods etc? The leisure battery in the car will charge from the engine from a dc to dc charger and solar on the roof. I want the leisure setup on the car as I also go camping without the caravan. Would appreciate your thoughts!
@muddyandsandy
@muddyandsandy 9 месяцев назад
Sounds fine...just remember to turn off your battery charger when on inverter..
@simontrotter2678
@simontrotter2678 6 месяцев назад
I had a camper van I built with a 3KW INVERTER , leaving the inverter on even without a load will drain the battery over time(I had an 260ah AGM ), lithium might be different and quality inverters may have less of a draw on the battery.
@richardsaunders5547
@richardsaunders5547 6 месяцев назад
@@simontrotter2678 yea I’m Familiar with parasitic draw and it will only be on when being used.
@simontrotter2678
@simontrotter2678 6 месяцев назад
Just thinking of extended periods of use, I found with my crappy AGM it drained pretty quick. I’ve sold my camper and bought a 2018 3.2 Wildtrak , next step buy a caravan and start the off grid process again this time with lithium🤣🤣
@jonk2185
@jonk2185 Месяц назад
What model is your changeover switch
@muddyandsandy
@muddyandsandy Месяц назад
Hager 40amp
@jonk2185
@jonk2185 Месяц назад
@@muddyandsandy thanks
@NeilF4x4Crusading
@NeilF4x4Crusading 7 месяцев назад
Great vid Who did you get to certify the 240v electrical work ? From what I understand you can do 12v wiring and you can plug an extension cord into the invertor but as soon as you start cutting cables that run 240v this work needs to be done and/or certified by a licence electrician ??
@muddyandsandy
@muddyandsandy 6 месяцев назад
I got a very local sparky to do it..
@petercarter6086
@petercarter6086 4 месяца назад
Hi there Why do you need an isolator switch as well as a resettable fuse, if you want to isolate the inverter couldn't you just switch the fuse of and reset it when you want to operate the inverter again ?
@muddyandsandy
@muddyandsandy 4 месяца назад
Yes you could just use the resettable fuse to turn off....but I perfered to have a isolator..as it's designed to be a switch...
@markobrien7463
@markobrien7463 10 месяцев назад
Hi muddy.. have brought same switchboard items.. am a sparky.. and any chance u able to draw up or do a schematic of yours 🤞🤞🤞
@muddyandsandy
@muddyandsandy 10 месяцев назад
Abit hard to send it here...but I did end up adding a rcbo next to inverter ..then run cable to change over switch...just made the outside socket wire into the 2nd input of the change over switch...fairy easy...change over switch has 2 inputs and one output....I put every socket on the inverter....and just turn off battery charger when inverter is on..
@markobrien7463
@markobrien7463 10 месяцев назад
@@muddyandsandy cheers much appreciated
@peterkelly4937
@peterkelly4937 10 месяцев назад
Hi, how many amps is your change over switch?
@muddyandsandy
@muddyandsandy 10 месяцев назад
40amps double pole...
@zaheersarwar7815
@zaheersarwar7815 11 месяцев назад
Will this system run a 50ltr electric air compressor, 1.8 kW 230v ?
@muddyandsandy
@muddyandsandy 10 месяцев назад
Yes it will....but just depends how long you run it for as batteys will be drained quickly...especially if agm batterys
@zaheersarwar7815
@zaheersarwar7815 10 месяцев назад
@muddyandsandy ideally it will be used to pump tyres. But this is not everyday only if and when required. What batteries would you recommend?
@thepawfectlap
@thepawfectlap 3 месяца назад
Hey mate! Where are you based?
@muddyandsandy
@muddyandsandy 3 месяца назад
Redlands Brisbane....
@lukesmith8290
@lukesmith8290 Год назад
Hi mate wouldn't doing it this way make your external male power input live? Or am I missing something.
@muddyandsandy
@muddyandsandy Год назад
Hey mate...inverter feed goes straight to a change over switch.....so there is no connection between inverter power and outside caravan input plug.....change over switch has 2 inputs and one output.....1 input inverter and other input is outside caravan plug........when you switch up to inverter it only connects to inside power..hope that makes sense...thanks for the comment
@smitsgarage
@smitsgarage Год назад
Thankyou. I am looking at doing the same thing and it was doing my head in. Cheers.
@muddyandsandy
@muddyandsandy Год назад
@coastalfurn I'm doing a video next week on power surges etc and I'll show that change over switch...it will be easier if I show it aswell
@user-io3lj7bn6p
@user-io3lj7bn6p Год назад
All thru a 10 amp plug . Not strictly correct
@muddyandsandy
@muddyandsandy Год назад
True...but the max my battery can output anyway is 2600w..was never planning on running 3000watt equipment...so it can't do more than 10amps anyway....that was my reasoning..cable can do 20amp..and the only difference between 10amp plug and 15amp plug is the earth pin...its the cable that is the most important thing, and that fine.....i could change the rcbo to 10amp and that would limit it for sure....thanks for your comment
@lewisbarnes4799
@lewisbarnes4799 Год назад
Are you a Sparky because I think thats abit much for non Sparkies ?
@muddyandsandy
@muddyandsandy Год назад
I am..but it's not to bad for someone that has basic skills and some tools...it's all 12volt so it's pretty safe, as long as you have some common sense....thanks for the comment
Далее
Renogy 3000 watt inverter 15 months on
10:07
Просмотров 59 тыс.
БЕЛКА РОЖАЕТ?#cat
00:28
Просмотров 392 тыс.
Should You Install A Consumer Unit In Your Campervan?
29:01
Electrical Standards - WHAT YOU NEED TO KNOW
21:30
Просмотров 8 тыс.