Тёмный

How to Install and Setup POW SunSmart10K Solar Inverter 

PowMr Solar
Подписаться 3,6 тыс.
Просмотров 16 тыс.
50% 1

Are you ready to take control of your energy supply and embrace renewable power solutions? Join us on our exciting journey to unlock the full potential of solar energy with the POW SunSmart10K solar inverter installation and setup guide!
In this highly informative video, we will walk you through the step-by-step process of installing and configuring the POW SunSmart10K solar inverter. Our expert technicians will share valuable insights, tips, and best practices to ensure a smooth and successful installation.
______________________________________________________________
Website
powmr.com/
Facebook
/ powmrsolar
Email:
support@powmr.com
See you in my next video! :)
______________________________________________________________
1: PowMr New 5KW Energy Storage System Unboxing
• PowMr New 5KW Energy S...
2: PowMr 10KW Solar Inverter Unboxing
• PowMr 10KW Solar Inver...
3: Detailed Solar Inverter Installation: A Step-by-Step Guide
• Detailed Solar Inverte...
4: Detailed Explanation of POW SunSmart5.5KW Time-of-Use Charging and Discharging
• Detailed Explanation o...
5: Inverter Setup Guide: A Comprehensive Tutorial for Beginners
• Inverter Setup Guide: ...

Наука

Опубликовано:

 

18 июл 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 93   
@TwoK24
@TwoK24 9 месяцев назад
Nice tutorial POWMR
@PowmrSolar
@PowmrSolar 9 месяцев назад
Thanks.❤
@JeffSmith-hq2gw
@JeffSmith-hq2gw 2 месяца назад
Impressive
@esdrasemile1450
@esdrasemile1450 6 месяцев назад
Good morning
@johnmelvin808
@johnmelvin808 5 месяцев назад
I've been utilizing my 10k solar inverter for nearly half a year, and overall, it has proven to be a highly satisfactory experience. However, I have observed that when encountering an error code, is there a more efficient method to reset the code without the need to power down the entire system and initiate a complete reboot? Thanks for a great product.
@PowmrSolar
@PowmrSolar 5 месяцев назад
Hi, please send your problems to this email: support@powmr.com. Please note that we may not be able to promptly respond to you due to the Lunar New Year. We apologize for the inconvenience this may take and thank you for your understanding. We wish you all the best!
@killshotking4262
@killshotking4262 17 дней назад
hi, are you able to adjust parameter 4? this is the battery cutoff voltage/switch back to grid threshold. I am unable to adjust it (when I make the adjustment and hit enter it seems to work but when I exit setting and then go back to check it is back to the default value rather than the one I programmed in). Also: have you had any issues since you made the above comment? Thanks and I hope you see this
@dannysuru
@dannysuru 11 месяцев назад
Hi looks good but can I use a generator to ac input when no sunshine and off grid ?
@PowmrSolar
@PowmrSolar 11 месяцев назад
Yes. you can use a generator to connect this model.
@ramsaybolton9099
@ramsaybolton9099 Год назад
Thank you for this video, it was quite comprehensive. Can this unit can be monitored by an app?
@PowmrSolar
@PowmrSolar Год назад
Hi, this APP(SmartESS).
@freddyc2121
@freddyc2121 7 месяцев назад
Hello, I need information about the wiring, I already saw the video,I already read the manuel, but in case I need to bypass from input from utility AC 240V, how do I apply the 240V comming from the mains to the inverter and the load , in the video it shows from input 120v , but if I need to use L1 and L2 + N at the input to feed the load and to charge the battery. Let's say, I use a laundry dryer at 240V connected to the inverter that will runn fom the batteries only of the utility power goes off, so initially it will take from utility at 240V and then if power from the grid fails, it will switch to batteries.
@davemacdonald5106
@davemacdonald5106 10 месяцев назад
is this CSA and UL certified
@sgn8471
@sgn8471 8 месяцев назад
Hi Powmr, which model and watts can be Parallels..? and what’s AC Main output and 2nd AC output…? Thanks….I’m going setup a 48v to 240v system
@PowmrSolar
@PowmrSolar 8 месяцев назад
Hi, this model can be used in parallel. The product link for your checking as below: powmr.com/products/hybrid-inverter-charger-5000w-48vdc-110vac-for-parallel
@MrBmonroe924
@MrBmonroe924 Год назад
are you able to wire two of these units in parallel?
@PowmrSolar
@PowmrSolar Год назад
This model cannot be used in parallel
@gabaradama144k9
@gabaradama144k9 7 месяцев назад
Do I have to have two units for 240 V split phase power
@PowmrSolar
@PowmrSolar 7 месяцев назад
One unit is ok.
@johnmelvin4091
@johnmelvin4091 11 месяцев назад
If i have a 4 -12 volt lifepo4 batteries setup for 48 volts, which setting should I use. LFP14, LFP15, and LFP16?
@PowmrSolar
@PowmrSolar 11 месяцев назад
Hi, LFP16.
@johnmelvin4091
@johnmelvin4091 11 месяцев назад
So, I read the manual from top to bottom and in it states that the LFP14, LFP15, and LLFP16 setting, is the number of cells in your battery setup. A 12 volt Lifepo4 battery has 4 cells x 4 batteries is 16 = LFP16. Just an FYI for anyone else wondering. Thank you for the quick reply.
@MiguelLlanes-vn1wc
@MiguelLlanes-vn1wc 9 месяцев назад
Puedo conectar paneles orientados al este a una entrada de paneles y orientados al oeste a la otra
@PowmrSolar
@PowmrSolar 9 месяцев назад
Yes, you can connect like this.
@JesusPaidForYourSins7
@JesusPaidForYourSins7 5 месяцев назад
Hello. I bought this inverter and have it connected to a 48v lifepo4 200ah battery. I have problems charging and discharging the battery. When it discharges, the inverter trips the OC protection. Are there specific parameters I should set for the battery? Would be great if the inverter and the battery could regulate these parameters.
@PowmrSolar
@PowmrSolar 5 месяцев назад
Hi, please send your problem to this email: support@powmr.com. Please note that we may not be able to promptly respond to you due to the Lunar New Year. We apologize for the inconvenience this may take and thank you for your understanding. We wish you all the best!
@harty9018
@harty9018 Год назад
ist der SunSmart10K in parallel Schaltung möglich ( 2x SunSmart10K auf 2 Phasen ?
@PowmrSolar
@PowmrSolar Год назад
Hi, this model cannot be used in parallel.
@mattclark7941
@mattclark7941 2 месяца назад
Hi will this inverter put out 230v to 240v in the single phase for uk?
@PowmrSolar
@PowmrSolar 2 месяца назад
Hi, this model is only for USA.
@MakeItAdmirable
@MakeItAdmirable Год назад
Can you do a video for SP5K 5000W 48Vdc 110Vac Hybrid Inverter Supports Up to 6 Units in Parallel
@PowmrSolar
@PowmrSolar Год назад
Hi, Ok. Stay tuned we will arrange later.
@horaciojimenez3586
@horaciojimenez3586 11 месяцев назад
Si, seria muy interesante conocer esa configuracion y el equipo
@atlw12210
@atlw12210 9 месяцев назад
POW-HVM5.5K-48V-LIP missing RS485 communication cable. How do I get one?
@mugiraharjo6270
@mugiraharjo6270 4 месяца назад
hope adding feature for paralel multiple inverter,
@PowmrSolar
@PowmrSolar 4 месяца назад
This model has a parallel version.
@healtechpr5659
@healtechpr5659 11 месяцев назад
Max. Voltage of Open Circuit 500Vdc, is it for each individual mppt, or is it 500vdc for both?
@PowmrSolar
@PowmrSolar 11 месяцев назад
For each, but the maximum input current is that the sum of the two does not exceed the PV maximum input current(22A)
@healtechpr5659
@healtechpr5659 11 месяцев назад
@@PowmrSolar Ok, to see if I'm okay… 1st Mppt 500Vdc 2nd Mppt 500Vdc 22A for both
@alisaggaf7497
@alisaggaf7497 3 месяца назад
Solar Panel array, Watts not to exceed 11KW
@MiguelLlanes-vn1wc
@MiguelLlanes-vn1wc 9 месяцев назад
Hola
@jojohnny4386
@jojohnny4386 6 месяцев назад
Hello my inverter HVM4.5K-24V At the 12 marathon it doesn't have volts. How to set the Back to Battery? But why the ampers? How should it be set up? Or do I need to update the software? Thank you
@PowmrSolar
@PowmrSolar 5 месяцев назад
Hi, please send your problems to this email: support@powmr.com. Please note that we may not be able to promptly respond to you due to the Lunar New Year. We apologize for the inconvenience this may take and thank you for your understanding. We wish you all the best!
@amelieelibh
@amelieelibh 8 месяцев назад
I installed the 10k power inverter with 8 550w solar panels in serial. Only in one MPPT, and I don't have batteries yet. It works sending V from the sonar panels and Utility to the load, but it is throwing an error 03. How can I configure it to work without requiring batteries?
@PowmrSolar
@PowmrSolar 8 месяцев назад
Hi, the POW SunSmart10K model, right?
@amelieelibh
@amelieelibh 8 месяцев назад
@@PowmrSolar correct!
@PowmrSolar
@PowmrSolar 8 месяцев назад
@@amelieelibh Please connect PV and mains power at the same time, then set AC 1ST in item 01 and LOD in item 34.
@amelieelibh
@amelieelibh 8 месяцев назад
@@PowmrSolar I already configured utility in the option 01, and mix load in the option 34. And it worked, but the battery alarm never finished and all the time throws fault (even working). Is there a way to configure it to avoid requesting for the batteries?
@PowmrSolar
@PowmrSolar 8 месяцев назад
@@amelieelibh You can turn off the alarm in item 25.
@christianbravophotography4705
@christianbravophotography4705 11 месяцев назад
How is the maximum capacity (kilowatts) in battery for this inverter?
@PowmrSolar
@PowmrSolar 11 месяцев назад
Capacity is not required, but we suggest not to connect too much (200AH-400AH)
@alisaggaf7497
@alisaggaf7497 3 месяца назад
Can I connect 5 Units of Lifepo4 batteries 51.2x280AH (parallel) to this inverter?
@muhammadshahzadyousaf1282
@muhammadshahzadyousaf1282 2 месяца назад
our inverter POW-HVM6.2M-48V-N installed a day ago, error 52 appears and the system is not restarting. what to do further? please advice.
@PowmrSolar
@PowmrSolar 2 месяца назад
Please send your problem to this email: support@powmr.com. Our teachnical staff will handle it for you.
@johsell07
@johsell07 11 месяцев назад
Do you have any e mail for support? I have a few questions of this sistem
@PowmrSolar
@PowmrSolar 11 месяцев назад
kindly contact this email: support@powmr.com
@technadi4556
@technadi4556 11 месяцев назад
has this inverter a limiter
@PowmrSolar
@PowmrSolar 11 месяцев назад
This model has built-in CT.
@vladflorin7821
@vladflorin7821 4 месяца назад
I have a question if not intruding, I recently bought a 10,2kw inverter and don't understand what they use two outputs for,Main output, Second output?? I'm under the impression that is not a 10kw inverter, but two inverters of 5kw each!?!? Please explain to me to understand, in the user manual it doesn't say anything about this subject.. thanks, I appreciate.. Looking forward for the answer
@PowmrSolar
@PowmrSolar 4 месяца назад
Hi, the distinction between primary and secondary. Under normal circumstances, the ordinary load is connected to the main load terminal. If the battery power is insufficient, the inverter will lose power and stop working. However, in order for some loads to be kept powered on all the time, there is a secondary load, which means that even if the battery power is a little low, the main load is still disconnected and only the secondary load is carried, thereby keeping the secondary load uninterrupted. This function requires setting items 41 and 42 to be turned on.
@johsell07
@johsell07 11 месяцев назад
How to contact you to buy the inverter?
@PowmrSolar
@PowmrSolar 11 месяцев назад
Hello, kindly check the website: powmr.com/
@MakeItAdmirable
@MakeItAdmirable 11 месяцев назад
What is the difference between LFP14, LFP15, and LFP16? Im not sure which one to select.
@PowmrSolar
@PowmrSolar 11 месяцев назад
Hi, we would like to know what is the voltage of your lithium battery.
@MakeItAdmirable
@MakeItAdmirable 11 месяцев назад
@@PowmrSolar 51.2 volt 100Ah
@PowmrSolar
@PowmrSolar 11 месяцев назад
@@MakeItAdmirable Recommend you choose LFP16.
@MakeItAdmirable
@MakeItAdmirable 11 месяцев назад
@@PowmrSolar Ok thank you!
@TwoK24
@TwoK24 11 месяцев назад
What is the proper procedures for switching ON the inverter which first PV, BATTERY, AC IN? and what is for switching OFF which first PV,BATTERY ,AC?
@PowmrSolar
@PowmrSolar 11 месяцев назад
Hi, you need to turn on the battery switch first, then PV, the last is AC IN. The order of turning them off is AC IN first, then PV, then battery.
@TwoK24
@TwoK24 11 месяцев назад
@@PowmrSolar thank you so much
@homeinspectionlosangeles4189
can this 10k inverter work off grid without the utility connected(while solar pv and battery are connected)??
@PowmrSolar
@PowmrSolar Год назад
HI, sure, this model can work off grid.
@Ozzie-bq8vq
@Ozzie-bq8vq 2 месяца назад
I just installed my 10K inverter and I can barely see the display, not bright enough, what am I doing wrong? Help!
@PowmrSolar
@PowmrSolar 2 месяца назад
Hello, please send your problems to this email: support@powmr.com. Our technical staff will check it for you.
@JosephCaile-js1wq
@JosephCaile-js1wq 5 месяцев назад
Where is the anti reflux settings?
@missinglink2081
@missinglink2081 4 месяца назад
why can't I change my parameter 01
@PowmrSolar
@PowmrSolar 4 месяца назад
Please send your questions to this email: support@powmr.com
@ridersmotoz2457
@ridersmotoz2457 10 месяцев назад
Still available and Hm??
@PowmrSolar
@PowmrSolar 10 месяцев назад
Hi, this model(POW SunSmart10K)?
@saulvasquez1058
@saulvasquez1058 6 месяцев назад
Please upload this video in Spanish. thank you
@bimmers323ci
@bimmers323ci 5 месяцев назад
Hi is this unit stackable
@PowmrSolar
@PowmrSolar 5 месяцев назад
Hi this model can't be used in parallel.
@bimmers323ci
@bimmers323ci 5 месяцев назад
@@PowmrSolar hi can this inverter run two 4hp motor @ 240v
@PowmrSolar
@PowmrSolar 4 месяца назад
@@bimmers323ci Hi, this inverter can not run two 4hp motor at the same time.
@bimmers323ci
@bimmers323ci 4 месяца назад
@@PowmrSolar ok the what can you recommend
@PowmrSolar
@PowmrSolar 4 месяца назад
@@bimmers323ci Hi, you can use two units.
@directionschoolnoorcampus
@directionschoolnoorcampus 9 месяцев назад
Price in pkr
@PowmrSolar
@PowmrSolar 9 месяцев назад
Hi, kindly check the product link: powmr.com/products/hybrid-inverter-charger-10kw-48vdc-split-phase-110vac-or-240vac
@atlw12210
@atlw12210 9 месяцев назад
POW-HVM5.5K-48V-LIP missing RS485 communication cable. How do I get one?
Далее
Quick Installation of PowMr 10.2KW Solar Inverter
1:23
Upgrading Our Solar All-In-One Inverter by PowMR
21:35
ЮТУБ ТОЧНО ВСЕ!
11:23
Просмотров 786 тыс.
Powmr Hybrid inverter screen
3:12
Просмотров 682
How to Setup the PowMr 10.2KW Hybrid Solar Inverter
11:56
Копия iPhone с WildBerries
1:00
Просмотров 8 млн