straight joint of underground cable
#Underground_Cable_Junct
#Straight_Joint
Their aluminium wire armour (AWA) for single core cables and steel wire armour (SWA) for multicore cables provide robust mechanical protection making these 11kV cables suitable for direct burial in the ground. These armoured MV mains power cables are more commonly supplied with copper conductors but they are also available with aluminium conductors upon request to the same standard. The copper conductors are stranded (Class 2) whereas the aluminium conductors are compliant to the standard using both stranded and solid (Class 1) constructions.
Conductor?
Class 2 stranded copper or Class 1 solid /Class 2 stranded aluminium
Conductor Screen?
Semi-conductive Cross-Linked Polyethylene (XLPE)
Insulation?
XLPE
Insulation Screen?
Semi-conductive XLPE
Meri video acchi Lage toh please like Kijiye comments kijiye aur mere is channel ko jis ke NAME ♥MM ASIF hy is ko subscribe kijiye Shukriya. aapka Pyara dost Mehar ♥Muhammad Asif.
♥Plz subscribe kijiye
ru-vid.com/show-UCiDA...
♥ ♥ ♥ ♥_____/LINKS\_____♥ ♥ ♥ ♥
► Facebook Page:➜ / mm-asif-564997130539877
► Instagram:➜ / asifshazada. .
► Google+:➜plus.google.com/b/10971302588...
► linkedin:➜linkedin.com/in/mm-asif-918258173
====__|Watch More Videos|__====
♥How To Electrical Pole Size In Urdu/Hindi | Types Of Electrical Pole Stay | Bijli Ka Khamba |
► • How Many Types Of Elec...
♥How To Use High Voltage Tester | Electric Detector Work | High Voltage Detector | Urdu/Hindi
► • High Voltage Detector ...
♥How To CT Energy Meter Connection | 3 Phase CT Meter | CT Installation In Urdu/Hindi |
► • How To CT Energy Meter...
♥How To Cable Size | Cable Size Chart | Cable Size Chart With Load | Cable Size Chart In Urdu/hindi
► • How To Cable Size | Ca...
♥How To Use Hilti Gun | Hilti Nail Gun | Hilti Powdered Actuated Tools | INTRODUCING | Urdu/Hindi
► • How To Use Hilti Gun |...
♥Fire In Electrical Store In Riyadh Saudi Arabi | Al janahain | الجناحین الریاض سعودی عرب
► • Electrical Fire In Wal...
♥Electrical Work Maintenance In Saudi Arabia Urdu/hindi
► • Electrical Maintenance...
♥Fuse Lagaane Ka Tarika 33kv/11kv Urdu/Hindi
► • Electrical Fuse Types ...
♥Track: Weero - Mates [NCS Release]
Music provided by NoCopyrightSounds.
Watch: • Weero - Mates [NCS Rel...
Free Download / Stream: ncs.io/MatesYO
how to joint underground cable,
underground cable straight joint,
11kv xlpe cable joint,
MM Asif,

Опубликовано:

 

13 апр 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 64   
@showdebolajandirasp100fute9
@showdebolajandirasp100fute9 6 месяцев назад
Congratulates, It's amazing services 😮
@sn7123
@sn7123 11 месяцев назад
Also the heat shrinkable sheath should be heated from center to outwards. This is the correct procedure...😮 Otherwise air bubbles may lock inside your joint.
@ZookLife
@ZookLife 9 месяцев назад
Make a video and show it
@sinoperture
@sinoperture 3 месяца назад
@@ZookLife You can search for it, if need be.
@DM-hk8gz
@DM-hk8gz 6 месяцев назад
Good job guys 👍
@xx__p_o_k_k_u__xx3243
@xx__p_o_k_k_u__xx3243 6 месяцев назад
Салам Алейкум, я с Кавказа и тоже кабельщик, интересно посмотреть как работают братья в других странах)
@paulpivnev5027
@paulpivnev5027 5 месяцев назад
Ну я бы своим за такое руки обломал...
@I_can_work
@I_can_work 5 месяцев назад
Nice video ok brother ❤❤
@abidali.6873
@abidali.6873 Месяц назад
Good 👍
@mmasif7364
@mmasif7364 Месяц назад
Thanks for the visit
@ShaheenKhan-uj4kz
@ShaheenKhan-uj4kz 4 месяца назад
😢❤Todays the 😊😊😊tooll 3 day and wayer 12 mater . Timer or taarem😮🎉❤😊😊
@user-jq7ip3ex9p
@user-jq7ip3ex9p 7 месяцев назад
한국 154kV 작업의 경우 준 크린 구역으로 크리닝과 접속부 이물질 방지와 전선 직진도와 고정에 주의를 한답니다. 잘 보았네요
@UmarSharif
@UmarSharif Год назад
Excellent Work!!!!!!! 👍👍👍👍👍👍👍👍👍👍👍 👏👏👏👏👏👏👏👏👏👏👏
@mmasif7364
@mmasif7364 Год назад
Thank you so much 😀
@zaqirkhan
@zaqirkhan 7 месяцев назад
Good job⭐👍
@nabiashraf6640
@nabiashraf6640 5 месяцев назад
Mashallah
@Electricalpower96
@Electricalpower96 6 месяцев назад
Hard work 👍@electricalpowerpk
@wesleyashley99
@wesleyashley99 7 месяцев назад
If they were connected in a staggered pattern there would be less of a bulge and wires should be color coded to make sure they don't get connected in the wrong order.
@pathan739
@pathan739 Год назад
Good work bro
@mmasif7364
@mmasif7364 Год назад
Thank you so much 😀
@abdulahmed9508
@abdulahmed9508 11 месяцев назад
Assalamalaikum iam India Telangana c bhai
@PeterJD35
@PeterJD35 6 месяцев назад
Not the correct contact plate for the crimper. This might work in an emergency but I would absolutely want to thermal test that joint over rated load to make sure it's good.
@pedrobritez8553
@pedrobritez8553 Год назад
Com el espacio que tiene devio hacer empalme escalonado para diminuir bulto en la aislacion y disipación de la temperatura que surgiera en el empalme
@ZookLife
@ZookLife 9 месяцев назад
Make video and show how
@gregwilliams386
@gregwilliams386 3 месяца назад
Looks like what a salesman would offer a bureaucrat. A lot of parts and labor.
@chevalierguillaume4834
@chevalierguillaume4834 11 месяцев назад
Where are the Wago when you need it ?
@davidhamm5626
@davidhamm5626 7 месяцев назад
Exactly what I was thinking...
@YuriWhite2251
@YuriWhite2251 6 месяцев назад
Вам дай волю вы в туалете станете ваго вставлять... Бгг
@jxwirecable
@jxwirecable 11 месяцев назад
Aluminum cable
@ranababarali7070
@ranababarali7070 Год назад
Mashallah,bhai in cable ki life kitni ha open kay mukablay main
@PeterJD35
@PeterJD35 6 месяцев назад
And the single phase wrap order is wrong. Glass then rubber than mastic. The shrink sheathe might provide enough insulation on its own. Prefer wide glass cloth instead of glass tape. That grease could provide a shorting path if it gets contaminated. Would rather use spray talc or PTFE tape.
@TuberNguyen
@TuberNguyen Год назад
Sao các bạn không đổ keo chống rò điện lên như thế nó đảm bảo hơn khi đấu nối chôn xuống đất..
@rohitmixlyricsraj2109
@rohitmixlyricsraj2109 Год назад
السلام عليكم
@_mo_5169
@_mo_5169 11 месяцев назад
Could you please tell the toold4name and every name of each percdure you did
@sudeepchakraborty5084
@sudeepchakraborty5084 Год назад
Ye background music to angey prash ke Aladdin wale series kahai
@animelover8971
@animelover8971 3 месяца назад
Bro mera interview ha cable jonter k pls help me???
@WaseemAkhtar5
@WaseemAkhtar5 Год назад
Australian building technology Ltd co kaisa hai Saudi Arabia me
@masumhossain5966
@masumhossain5966 Год назад
KSA 3 phase meter working best 3 company ka naam bolo
@thembelihlezulu2474
@thembelihlezulu2474 3 месяца назад
I have a question, why to other side is long and the other of the cable is short what is the main reason
@ammaraloush6313
@ammaraloush6313 5 месяцев назад
Dear sir ,, How you can identify the route of of cable ?
@noelfaithfulkari2857
@noelfaithfulkari2857 9 месяцев назад
No description on the procedure's. Names of items used
@Cartoonofficial7
@Cartoonofficial7 6 месяцев назад
Sir ya training kha sy mily gii
@parthkanani9249
@parthkanani9249 10 месяцев назад
Which Tool Is Used To Crimp The Lug??
@BehshadSamimi
@BehshadSamimi 4 месяца назад
Battery powered crimper !!
@sameetbehera7861
@sameetbehera7861 5 месяцев назад
Mastik tube exple me
@paulpivnev5027
@paulpivnev5027 5 месяцев назад
Это кабель из сшитого полиэтилена? Его нужно специальными ножами разделывать 😢😢😢
@bluka5777
@bluka5777 6 месяцев назад
How you know if the phases are correct in the 3 conductor cable ?
@Siranjeevi1
@Siranjeevi1 5 месяцев назад
In Singapore we put a facing kit on the far end and we pick up the color on the jointing side 😊
@rohitmixlyricsraj2109
@rohitmixlyricsraj2109 Год назад
Bai abka fohn nambbar dedo
@sn7123
@sn7123 11 месяцев назад
Y 3 joints are at the same place?! It should be at 3 different places for better efficiency.
@dawoodmughal
@dawoodmughal 11 месяцев назад
Hv joint as pr SEC STANDARD😊
@rajaadnan2165
@rajaadnan2165 10 месяцев назад
Company ka ky name ha
@biok2006
@biok2006 Год назад
Mute voice next time No sense listen voices at 2x
@2loco
@2loco 11 месяцев назад
Turn down your volume lol
@emperorfancypants2512
@emperorfancypants2512 5 месяцев назад
You need to press 4 times each side not 3 times wtf
@christopherswanton4796
@christopherswanton4796 5 месяцев назад
another ticking timebomb, HV jointing needs to be dead on balls accurate to the mm, no gaps, perfect moisture and air seals ..that is definatly going to fail. and proper shit cables
@christopherswanton4796
@christopherswanton4796 5 месяцев назад
iwork as a hv jointer on offshore windfarms, anyone who thinks this is good, give your a head a wobble, it takes me 2 maybe 3 hours to properly prepare 1 core for termination...from the very start ...shit, the semi con for example needs to be a perfect transition to insulation the sudden dip will lock air, and or water, with the biuld up of energy and heat that air pocket then triggers something called the corrona affect, I.E ironisation, AKA air becomes conductive, just like lightning, and BOOOOOOOOM failure, thats not even looking into the rest, not to mention no cleaning sanding or heating of cable to create a perfect moisture seal before the joint, cable shit procedure shit joint mega shit, not these guys fault ..untrained and unaware
@phenry5083
@phenry5083 11 месяцев назад
Direct Burial? Yeah.. no. Absolutely not.
@miroslavzatko1477
@miroslavzatko1477 9 месяцев назад
Celé zle.cele zle Kokoty
@venkatarr
@venkatarr 9 месяцев назад
BGM is worst 🥴🥴
@mdsahidali1160
@mdsahidali1160 5 месяцев назад
Saudi mey hai aap to number send kijiyega please
Далее
EVOLUTION OF ICE CREAM 😱 #shorts
00:11
Просмотров 3,1 млн
Cable jointing at a cannabis farm - Part 2
43:00
Просмотров 165 тыс.
HV CABLE TERMINATION
16:33
Просмотров 9 тыс.
Resin Straight Joint WMB 24kV 3Cx240mm2  Cellpack
18:03
Switching 11kV VCB Tamco
7:34
Просмотров 2,5 млн
Triple through joint! Two 4c x 185 and one 4c x 70
5:43
How 2500KVA Electric Transformers are Made
12:40
Просмотров 2,9 млн
EVOLUTION OF ICE CREAM 😱 #shorts
00:11
Просмотров 3,1 млн