Тёмный

How to Make a Remote On and Off Switch with a Contactor - Latching Circuit 

GalcoTV
Подписаться 125 тыс.
Просмотров 396 тыс.
50% 1

Making a latching circuit with a contactor presented by Katie Nyberg for Galco TV. Buy the items featured in this video at 800-337-1720 or visit: www.galco.com/g...
This video will show you how make a latching circuit or a on/off switch with a contactor or relay. With a latching circuit, the contacts will remain on once input power is applied and will remain on until the connection is broken. For this set up you will need a contactor, auxiliary contact, normally open pushbutton switch and a normally closed pushbutton switch. A relay can be used in place of a contactor as long as there is an auxiliary contact that will close when the coil is actuated.
Sign up for Galco’s newsletter that features our newest products, our can't-miss deals, our best videos, and total access to Galco’s electronics expertise: www.galco.com/e...
Connect with us!
plus.google.co...
/ galcoindustrial
/ galcoindustrial
/ galco-industrial-elect...
Don't forget to like and comment on this video, and subscribe to our channel!
Galco is a Factory Authorized Stocking Distributor for Over 150 Brands of Industrial Electrical & Electronic Automation, Controls and Component Products; On-Site and Send-In Repair Services for Industrial Control & Automation Products for Over 2,000 Brands; Engineered Systems Integration, Retrofits & Upgrades for Variable Speed Drives, CNC, PLC Systems, Dynamometers & Test Stand Applications. Visit us online at www.galco.com or call us at 800-337-1720.
www.galco.com/s...
With respect to the usage, installation or assembly of any products described in this video, Galco Industrial Electronics, Inc., a Michigan corporation, encourages you to follow the requirements and/or guidelines of: i) the Occupational Safety and Health Act of 1970, Public Law 91-596, as amended, and all laws, rules and regulations implemented in relation thereto; ii) the National Electric Code®; and iii) NFPA 70E®. Any installation, assembly or work described in this video should be performed by a qualified licensed electrician.
GTV, Galco, galco.com, Galco Industrial Electronics, and Galco Industrial Electronics, Inc. are registered and/or pending registered trademarks under the U.S. Patent and Trademark Office, assumed names, registered domain names, and/or trade names of Galco Industrial Electronics, Inc., a Michigan corporation.
LEGAL DISCLAIMER:
While we have made every attempt to ensure that the information provided is accurate and has been obtained from reliable sources, Galco is not responsible for any errors or omissions, or for the results obtained from the use of this information. All information is provided "as is", with no guarantee of completeness, accuracy, timeliness or of the results obtained from the use of this information, and without warranty of any kind, express or implied, including, but not limited to warranties of performance, merchantability and fitness for a particular purpose. At all times you should defer to the instructions and safety guidelines issued by the manufacturer. In no event will Galco, its agents or employees thereof be liable to you or anyone else for any decision made or action taken in reliance on the information provided to you or for any consequential, special or similar damages, even if advised of the possibility of such damages.

Наука

Опубликовано:

 

5 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 70   
@pathill6428
@pathill6428 Год назад
Finally plain and to the point with out all the bs. Great video, thank you😊
@gh2110
@gh2110 4 года назад
Ur great” ur the first one who shows the neutral. That was the hardest thing to see when you first start. U must understand the circuit not just remember how the wires go. Uv done a great job.
@mitchtaylor7725
@mitchtaylor7725 5 лет назад
Perfectly explained. 10/10. Exactly what is needed to know and diagram actually got rid of my confusion over the latching/ momentary switch. Yew!
@GalcoIndustrial
@GalcoIndustrial 5 лет назад
Thank you, glad you liked it
@anandjoshi8554
@anandjoshi8554 2 года назад
@@GalcoIndustrial Can a plc input error sensor relay can be connected in between the auxiliary and contactor circuit.......so that if relay trigger on any error, the auxiliary connection breaks ...thus breaking the supply from contactor to load permananetly !!!(until start again ) ???
@jokatech1
@jokatech1 4 года назад
2020... still helpful... today is when I have understood what happens when you press those buttons... thanks a lot...
@rashedpramanik717
@rashedpramanik717 7 лет назад
Very nice. Galco tv is the best for help to anyone. Thumbs up.
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
Thank you for your kind words Rashed. Anything else you would like to see on Gtv, please don't hesitate to post here, ok?
@rashedpramanik717
@rashedpramanik717 7 лет назад
GalcoTV, thank you. I was just appreciate to Galco TV because this video was helpfully for me. That's it......
@David-uj2ms
@David-uj2ms 4 года назад
wow. finally. been looking 4 this 4 hours.
@tonyarroyo931
@tonyarroyo931 6 лет назад
Love watching her explain things . Awesome video thank you
@stephenakapo1994
@stephenakapo1994 3 года назад
Good explanation thanks
@ranat5526
@ranat5526 3 года назад
Very interesting, I shall be always grateful to thee!!
@Froggability
@Froggability 3 года назад
Should mention the biggest reason for this type of circuit : SAFETY. The NC stop button is mandated for any moving machinery conveyor belts and the like. The slightest loose wire and she all grinds to a halt
@anandjoshi8554
@anandjoshi8554 2 года назад
Can a plc input error sensor relay can be connected in between the auxiliary and contactor circuit.......so that if relay trigger on any error, the auxiliary connection breaks ...thus breaking the supply from contactor to load permananetly !!!(until start again ) ???
@abubakaribrahim7606
@abubakaribrahim7606 7 лет назад
very interested, thanks
@andIloveH
@andIloveH 8 лет назад
sweet industrial presenter
@tusharsharma310
@tusharsharma310 7 лет назад
thanks i was trying to make a diagramm , this vid helped me
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
Glad we were able to help you out!
@bluetorch13
@bluetorch13 8 лет назад
this is freaking awesome!
@mohsayah5999
@mohsayah5999 7 лет назад
very good
@saravanane1728
@saravanane1728 6 лет назад
nice video. Pls. make video of remote operated 3ph contactor without wire connection.
@Tobikglobik
@Tobikglobik 8 лет назад
I am wondering, what if the start button is held down a few moments longer would not we get a short circuit?
@ahmedebrahim8237
@ahmedebrahim8237 8 лет назад
Its the same line connected, there is no short at all.
@charbelcharbel941
@charbelcharbel941 7 лет назад
Hi there! Pls can u show me how to wire a push botom for an electrical generator start& stop . Thanks
@Rupan-rx
@Rupan-rx 2 года назад
I’m trying to wire both switches into the same circuit and cannot get the rotary switch to shut the power off. Which is a no go for my dual pump hydraulic steering system.
@asadbabil7120
@asadbabil7120 3 года назад
Can u do ats ...
@panospeters8195
@panospeters8195 7 лет назад
Very fine explanation! Can you make a video refering to a DC to AC transfer switch wiring a domestic instalation electr. board from a photovoltaic battery- inverter circuit? Thank you!
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
I'll pass this along.
@mahfuzahamed8025
@mahfuzahamed8025 8 лет назад
Awesome! !!
@vijayalakshmiengineeringwo4587
does its possible two to connect 2 vfd in single switch for start and other single switch for stop
@rafiqjoyia5555
@rafiqjoyia5555 7 лет назад
thanks
@leoaborquiz3554
@leoaborquiz3554 7 лет назад
can make video for auto,off,on lighting contactor please
@sanjayakumarpatra5740
@sanjayakumarpatra5740 6 лет назад
both local and remote start or stop in one common holding, please make this type video
@GalcoIndustrial
@GalcoIndustrial 6 лет назад
Sorry Sanjaya, but your request makes no sense, please try making your request another way.
@NazmulIslam-ef3iv
@NazmulIslam-ef3iv 7 лет назад
i have two areas 3 phase line if one is gone auto switch to other area's line. Its like double pole single through for 3 phase. what i can use for this ?
@gajanandyadav6001
@gajanandyadav6001 5 лет назад
Good
@aligholipoor6924
@aligholipoor6924 8 лет назад
perfect
@chaselogistics2842
@chaselogistics2842 7 лет назад
awesome well done please send me more video and circuit diagram. thanks
@mrchinar145
@mrchinar145 7 лет назад
you are awesome .
@RakeshKumar-ye6xx
@RakeshKumar-ye6xx 6 лет назад
muje remot canection ke bare me jankari chahiye jo panel ke push baton se bhi on ho jaye
@yohkodevilhunter8292
@yohkodevilhunter8292 7 лет назад
What if the load is 120VAC, but the contactor coil is 24VAC?
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
In your case you will have to wire the load circuit and latch circuit separately. You will also need a 24volt supply in addition to the 120volt supply we demonstrate here, ok? OR,,, you can replace the coil in the relay/contactor with a 120volt rated 1. After that the wiring diagrams are the same.
@yohkodevilhunter8292
@yohkodevilhunter8292 7 лет назад
Thanks. I have two older sprecher + schuh CA3-23-10 and CA3-16-10. Any idea who would make a 120VAC coil for them? Although I think it would be cheaper just to buy a new contactor.
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
Sure, just give us a call at 800-521-1615 and ask for sales, they can tell you if we carry those coils, and what they cost or the cost of a new contactor, ok?
@Froggability
@Froggability 3 года назад
You have enough spare poles there so you're away laughing!!
@JesusCruz-wt2zp
@JesusCruz-wt2zp 4 года назад
How I find this contactor in your store what's code
@jamesreal7158
@jamesreal7158 7 лет назад
Can I use a push pull power transformer to step down my heavy duty relay on ATS
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
Push/Pull power transformer? ATS?
@eddieed9684
@eddieed9684 6 лет назад
What if i replace the push button with ordinary wall switch. Can this still works?
@GalcoIndustrial
@GalcoIndustrial 6 лет назад
Yes you could
@Froggability
@Froggability 3 года назад
"Momentry press" wall switch :Yes. Otherwise urk no! Pressing the stop would keep coming back on again 🥴
@lisx8442
@lisx8442 4 года назад
Do you know any contactor which can switch between two supply lines to one load ? I want to control it by a digit timer to use One supply line at a time
@Froggability
@Froggability 3 года назад
Just use a N/C contact looped load side to N/O contact
@anandjoshi8554
@anandjoshi8554 2 года назад
@@Froggability Can a plc input error sensor relay NC can be connected in between the auxiliary and contactor circuit.......so that if relay trigger (by any error in plc /load side) , the auxiliary connection breaks ...thus breaking the supply from contactor to load permananetly !!!(until start again ) ???
@Bs-wv9ii
@Bs-wv9ii 7 лет назад
روعة حلوة
@sulfiksa7796
@sulfiksa7796 7 лет назад
Please Normal close normal open please details
@JMPulido55
@JMPulido55 2 года назад
This video would have been much better without the loud background music.
@Mamdouh-morsi
@Mamdouh-morsi 6 лет назад
روعه
@GalcoIndustrial
@GalcoIndustrial 6 лет назад
شكرا
@Chaudhary-concrete
@Chaudhary-concrete 6 лет назад
Informted ve
@chagaarbellal4983
@chagaarbellal4983 5 лет назад
Are you single? 😏😏😏 Btw thanks for this job
@GalcoIndustrial
@GalcoIndustrial 5 лет назад
Welcome
@flow5718
@flow5718 5 лет назад
I remember seeing her with a Polish looking name in one of her other videos. So I reckon she's married now, too late buddy!
@DNL82
@DNL82 3 года назад
🤔🤔🤔
@karnvir20
@karnvir20 8 лет назад
you are so beautiful
@rickjeffjeff
@rickjeffjeff 6 лет назад
karnvir singh She is working
@Bs-wv9ii
@Bs-wv9ii 7 лет назад
راسليني
@jeremymcclanahan2389
@jeremymcclanahan2389 4 года назад
quarter says this broad doesn't have a clue what she is talking about
@abdulqadir150
@abdulqadir150 6 лет назад
Good
Далее
The Self-Holding Push Button Explained
9:47
Просмотров 391 тыс.
HOW TO TEST A CONTACTOR
11:56
Просмотров 143 тыс.
What is a Contactor? | Working Principles
9:47
Просмотров 275 тыс.
Contactors: how we power the big stuff
25:50
Просмотров 1 млн
What is a Contactor?
2:36
Просмотров 667 тыс.
What is a Contactor and How Does it Work?
20:51
Просмотров 177 тыс.
eBay CJX2 industrial contactor teardown.
18:40
Просмотров 120 тыс.
ИГРОВЫЕ НОУТБУКИ ОПАСНЫ? 😮
0:45
Мой новый мега монитор!🤯
1:00
Смартфоны миллиардеров 🤑
0:53