Тёмный

How to pass strong column weak beam check in ETABS Tutorial 

Engineering Learning Platform
Подписаться 23 тыс.
Просмотров 15 тыс.
50% 1

Опубликовано:

 

18 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 25   
@EngineeringLearningPlatform
@EngineeringLearningPlatform 3 года назад
Watch, "How to pass strong column weak beam check in ETABS Tutorial"
@zahidairfan6161
@zahidairfan6161 3 года назад
strong column weak beam check was an awaited tutorial , thanks
@laythhasan518
@laythhasan518 8 месяцев назад
thanks for sharing this video , I would like to ask , is it needed to use modifier 0.25 for slab in slab beam system, I checked ACI-318 - 19 for that and its written that its necessary for flat plates and flat slab
@dilipngangom4198
@dilipngangom4198 2 года назад
Does ETABS check the shear strength of Beam-Column joint as per IS:13920-2016 cl.9 over and above Strong column-Weak beam check? How can I verify the check?
@Engrwaleed555
@Engrwaleed555 3 года назад
AOA brother. Udemy par ju course ap me upload kia hai us mai detailing ka portion cover kia hai ap ne? I mean complete working drawings ju ham banate hein submission ke leye.
@EngineeringLearningPlatform
@EngineeringLearningPlatform 3 года назад
No, it's an ETABS course primarily, but additionally design aspects are covered and you can check the topics covered on the landing page of course: www.udemy.com/course/etabs-rcc/?referralCode=4F571121E8073D773BE7
@gowthamiv4841
@gowthamiv4841 2 года назад
its nice..what about the size of 24" x 24" by increasing column will it feasible to adopt though the member size passed???
@EngineeringLearningPlatform
@EngineeringLearningPlatform 2 года назад
Sorry the question is Unclear. However if a size is passing checks then there would be no reason to increase size
@gowthamiv4841
@gowthamiv4841 2 года назад
@@EngineeringLearningPlatform 24" x 24 " size passed once 18"x18" not passed..but adopting of 24 " is feasible for residential??
@EngineeringLearningPlatform
@EngineeringLearningPlatform 2 года назад
@@gowthamiv4841 it is totally dependent on the project I cannot judge that without looking at drawings, it's an Engineer's call and judgement
@andresdavidtorrescarranza1953
@andresdavidtorrescarranza1953 2 года назад
how can i check strong column weak beam if I have a intermediate sway? as We know, Etabs just calculates strong column weak beam for special moment frames.
@EngineeringLearningPlatform
@EngineeringLearningPlatform 2 года назад
Didn't get the question
@andresdavidtorrescarranza1953
@andresdavidtorrescarranza1953 2 года назад
@@EngineeringLearningPlatform Hi, thank you for aswering me, I mean, when I have a intermediate sway and I want to check 6/5 beam/column capacity ratios OR column/beam capacity ratios I get from Etabs N/A, it happens because Etabs Just calculates these capacity ratios for special frame moments, so as I mention before, I have a intermediate sway and I want to do these Checks. How can I check 6/5 beam/column capacity ratio in an intermediate sway?. In this video you are working whit a special frame moment so you can check 6/5 beam/column capacity ratio.
@adrianuslahiwu1002
@adrianuslahiwu1002 2 года назад
are the wall loads include in mass source ??
@EngineeringLearningPlatform
@EngineeringLearningPlatform 2 года назад
They must have to be
@civilideas1925
@civilideas1925 2 года назад
👍🏻
@zahoorahmadnisar5841
@zahoorahmadnisar5841 3 года назад
Can you please share any technical doc that how etabs calculates it.
@EngineeringLearningPlatform
@EngineeringLearningPlatform 3 года назад
Go to Etabs help menu, click on manuals there you can see list of manuals of different codes, see for your code and the pdf manual will open
@rcbsht9644
@rcbsht9644 2 года назад
can you explain the color of column it displays as red pink and sometimes as black
@EngineeringLearningPlatform
Red is failure. Black is if you haven't designed it
@dibesshrestha796
@dibesshrestha796 3 года назад
What does N/A mean in c/b capacity ratio
@EngineeringLearningPlatform
@EngineeringLearningPlatform 3 года назад
Mostly arises when the beam is not assigned "beam property" happens by mistake, or if the joint is not properly forming at common node or even releases can cause this issue.
@4ta01_josuadmarthrietchyri7
@@EngineeringLearningPlatform How ti fixed it? please answer.
@EngineeringLearningPlatform
@@4ta01_josuadmarthrietchyri7 select the members, go to design and then "overwrite the frame design procedure" to correct one. If concrete so concrete or steel so steel
@zulkarnainbinmohdsalleh2024
@zulkarnainbinmohdsalleh2024 7 месяцев назад
Confused…
Далее
MODEL MASONRY STRUCTURE IN ETABS PART 1
33:53
Просмотров 21 тыс.
Awareness on Using Stiffness Modifiers in Etabs
10:24
Strong Column Weak Beam Design
22:49
Просмотров 10 тыс.
How to calculate seismic joint in Etabs
17:19
Просмотров 2,2 тыс.
Beam Detailing using Etabs Result
11:09
Просмотров 40 тыс.
ETABS Beam Analysis & Design verification
20:05
Просмотров 4,9 тыс.