In manual failover, we can perform Complete Failover and Immediate Failover. In the complete #FailOver, it attempts to minimize #data loss by applying all #redo log generated on Primary #Database will be applied to a #standby database. This is the default method of failover.
In immediate failover, no additional data is applied on a standby database. This is fastest and we need to explicitly define this.
00:00 What is a Failover?
06:00 Crash primary database
08:08 Minimize data loss
09:17 Check for redo gap
11:00 Start failover
13:03 Check client query
Rebuild Primary
17:53 Rebuild Primary after failover
18:46 Find SCN at which standby become primary
21:24 Flashback crashed primary database
24:39 Convert crashed primary to physical standby
28:24 Revert to the original configuration
28:51 Perform manual switchover
29:07 Convert primary to standby
29:49 Convert standby to primary
30:14 On new standby-Initially your primary database:Start MRP
32:04 RMAN in Data Guard Configuration
32:39 How do you register a standby database to catolog?
33:00 Backup control file on primary
34:35 Set proper retention policy
35:49 How do you register with primary database with catalog?
Website: www.dbagenesis.com/
Facebook: / dbagenesis
Instagram: / dbagenesis
Twitter: / dbagenesis

Кино

Опубликовано:

 

30 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 12   
@rajatsanwal9919
@rajatsanwal9919 2 года назад
Arun sir, at 13:33 u r creating table and inserting data. But you are connected via sys user and such objects created are not shipped to standby , then why u shown example of creating table via sys schema?
@serhatcelik1185
@serhatcelik1185 2 года назад
Hello Dear. I have a question. My enviroment information like this. A >Primary DB 12c B>First Physical Standby DB 12c C> Second Physical Standby DB 12c. We will perform failover test from A to B in my company. Temporary I will cancel MRP on C. After failover I will reinstate A using flashback technology there is no problem here. I will start MRP on A and there is no problem here, also. After tests are completed I will switchover from B to A. A will be primary and B will be standby as before. As you know after failover, B will have new incarnation and log numbers are reseted. After all tests if I start MRP on C, what will happen? I think that I will lost my C physical standby db. Because A and C will have different incarnation, right? If you clarify, appreciated!
@tarunbhardwaj7967
@tarunbhardwaj7967 4 года назад
Dear Arun, does the database gets new incarnation(log sequence) in case of switchover too. I haven't performed switcher till now..
@dbagenesis
@dbagenesis 4 года назад
Why not perform once and check yourself !! It will be fun ;)
@nikitapatil9803
@nikitapatil9803 5 лет назад
Hey can you share doc link so that we can refer
@ssoo1985
@ssoo1985 2 года назад
Hey can you share doc link so that we can refer?
@ssoo1985
@ssoo1985 2 года назад
hi, any one have these docs and can share it please ??
@dbagenesis
@dbagenesis 2 года назад
www.support.dbagenesis.com/post/performing-manual-failover-on-physical-standby
@mahavishnu5498
@mahavishnu5498 2 года назад
Fail over oprtaion its peform automatically in protection mode its Right I am wrong
@naseemshaik32
@naseemshaik32 4 года назад
Hey can you share doc link so that we can refer
@dbagenesis
@dbagenesis 4 года назад
support.dbagenesis.com/knowledge-base/perform-manual-failover-on-physical-standby/
Далее
Oracle Data Guard Manual Failover Steps
22:19
Просмотров 9 тыс.
Oracle 19c Data Guard on Windows Step By Step Setup
1:07:18
Oracle Data Guard Client Connectivity TNS Entries
34:42
Understanding Redo Transport in Oracle Data Guard
25:39