This tutorial show how to carry out earth resistance test for commercial and resident building . Proper setting is importance for getting the better and accurate test result .

Опубликовано:

 

1 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 243   
@muhdsolihin2641
@muhdsolihin2641 Год назад
should be disconnecting earth cable from house to ground chamber first. so you will get the purest ground resistance.
@pankajmishra43
@pankajmishra43 Год назад
Hiiii... You mean, first disconnect the earth cable from earth pit?? OR Can we shutdown the entire system before measuring earth resistance?? Pls guide
@Sim_Tiby
@Sim_Tiby Год назад
Disconnect the earth cable.
@DiReal_Donclassy
@DiReal_Donclassy Год назад
Of course he must have done that before starting the test otherwise the resistances of home equipment will distort the result
@lonedragon4410
@lonedragon4410 2 года назад
Below 5ohm is acceptable right?
@rictorrictor888
@rictorrictor888 2 года назад
Yes
@fje1948
@fje1948 Год назад
The video I was looking for! Excellent explanation of the test. Thank you so much! Ps: The background music is pleasant and appropriate!
@ervingjonaj9082
@ervingjonaj9082 8 месяцев назад
music is shocking
@wazzer5293
@wazzer5293 10 месяцев назад
Sir, how 1). If earth got voltage, what is the next action.. 2). When to use the setting mode 200 & 2000? Apprecite ur answer
@manjunathamanju6204
@manjunathamanju6204 3 года назад
Thank you Sir this video very useful for all Electrical engineers
@haseebali499
@haseebali499 11 дней назад
One more thing what's the distance between two consecutive Earth Pit what's the exact standard if you can please explain this the the minimum distance between two consecutive Earth pits
@mohamadasriabdulazid4784
@mohamadasriabdulazid4784 3 дня назад
20 meter center spike 20 meter end spike from center spike
@Mike-ry4ti
@Mike-ry4ti Год назад
Your value of 1.63 ohms is a little high. Ideally less than 1 ohm is what you want...
@o-techtips3871
@o-techtips3871 3 года назад
Thank you very much for your sharing very informative tips☺️
@electroboy3607
@electroboy3607 Год назад
Good job..🎉 im practical test
@neilblenkinsop2613
@neilblenkinsop2613 Год назад
To individually test the earth rod disconnect tape from earth rod
@sanjeevraghav3700
@sanjeevraghav3700 2 года назад
Very nice vedio 👌👌kudos to your effort 🙏🙏👌
@30mAkills
@30mAkills Год назад
Shifting potential spike towards right and left is wrong.
@AutodidactEngineer
@AutodidactEngineer Год назад
The test should be done preferably during the driest season to prevent moisture from ruinning your values!
@File-Transfer
@File-Transfer 6 месяцев назад
I have a question, engr. Why is it required in the earth resistance tester manual to damp the surroundings?
@AutodidactEngineer
@AutodidactEngineer 6 месяцев назад
@@File-Transfer I don't know about that
@francisrayang805
@francisrayang805 3 года назад
Hi sir. You did a very informative video thanks. I've a question for you.In the video you did the test on a big compound. I'm in a terrace house and the compound is very limited. I can't pull the yellow and red cable that long..only 3-4 meters to the nearest soil. Will it affect the reading? Please advice thks.
@rictorrictor888
@rictorrictor888 3 года назад
In that situation ..You can try nearest area to ground the spike ..
@rictorrictor888
@rictorrictor888 2 года назад
in that situation ..yes..
@30mAkills
@30mAkills Год назад
You have to maintain distance. Please read my other comments. Get permission from neighbours.
@muhammadaresyamilbinazman7935
@muhammadaresyamilbinazman7935 2 года назад
Tumpang tanya, kan ada 20ohm, 200ohm, dan 2000ohm. Yang tu nak laraskan berdasarkan faktor apa ye?
@fidelcatsro6948
@fidelcatsro6948 Год назад
dasarkan 20ohm setting
@FabioHM71
@FabioHM71 3 года назад
the operator wears the helmet because there are suspended loads?
@rictorrictor888
@rictorrictor888 3 года назад
He worries falling mango fruit..hahaha
@FabioHM71
@FabioHM71 3 года назад
@@rictorrictor888 hahahaha ;-)
@fidelcatsro6948
@fidelcatsro6948 Год назад
there are flying cats around in the neighborhood
@aubreynorkee6854
@aubreynorkee6854 Месяц назад
Thanks again
@gohpoikheng6030
@gohpoikheng6030 2 года назад
May i know why the cable for current is longer than the voltage?
@raemondbradford1629
@raemondbradford1629 2 года назад
When current is injected into the earth, then the voltage will change around the location of injection. The voltage reference cable spike needs to be some distance from the points where current is injected or removed, in order to try and find a location with minimal disturbance of earth voltage potential.
@GUDANGLAMPUSURYA
@GUDANGLAMPUSURYA 2 года назад
Om untuk mengetahui brp kedalaman grounding rod yg di tanam bagaimana ya ? 🙏
@GUDANGLAMPUSURYA
@GUDANGLAMPUSURYA 2 года назад
Apakah bisa di test dgn ohm meter tersebut
@rictorrictor888
@rictorrictor888 2 года назад
Kedalam nya sehingga rod gak bisa masuk lagi..baru di uji..jika masih tidak mendapat kan bacaan yg dikehendaki..buat point baru sehingga mendapat bacaan yg paling rendah
@noelfaithfulkari2857
@noelfaithfulkari2857 Месяц назад
Please could you explain the operation of the meter and the readings.
@MrSyahryzal
@MrSyahryzal 3 года назад
Mudah untuk difahami... Lama mencari video earthing test untuk menambah ilmu. Terima kasih boss
@matsetizar65
@matsetizar65 5 месяцев назад
when lightning strikes the earth doesn't the surge enter the house via the earth wiring? If so isn't it dangerous, probably better not to have any earthing system at all?
@ahmedbelazi2318
@ahmedbelazi2318 Год назад
Thank you for the effort made in the video.... I have a question... Is it true that the yellow wire is supposed to be an extension of the red wire, meaning on one line to give the reading... Why change in yellow only and should it be changed in red? ??
@kennedymutuku8950
@kennedymutuku8950 2 года назад
Hello Sir,what if the result is above 10,let say 50..how can you improve this to 5?
@AutodidactEngineer
@AutodidactEngineer Год назад
Use a combination of vertical and horizontal grounding! My tip would be get copper/or in poorer countries galvanized pipe works well enaugh and install it in conjunction with galvanized steel bar/ or do the same but with copper if you can afford it!
@fidelcatsro6948
@fidelcatsro6948 Год назад
add more earthing rods all around the place the more the better🐱👍🏿
@neilblenkinsop2613
@neilblenkinsop2613 Год назад
All earth rod supplies these days are carbon steel with copper coating add to and go deeper using brass connection.
@electroboy3607
@electroboy3607 2 месяца назад
Good interesting vedio😊😊😊
@bundaajhalah
@bundaajhalah 4 года назад
Hadir nyimak 👍
@rictorrictor888
@rictorrictor888 4 года назад
thank you so much
@fauzibafana9089
@fauzibafana9089 2 года назад
Can i know whether before the individual earth rod being tested you have to remove the connection of the earth rod from the rest.
@gniraj8501
@gniraj8501 2 года назад
I am also have same question.
@30mAkills
@30mAkills Год назад
Yes it should be disconnected from service. If the voltage is more than 10 it will destroy the meter and also give false reading. Please read the user manual reg the max voltage limit that the meter will work safely in energised service without disconnection.
@VlogSidah
@VlogSidah 4 года назад
Mantap tuan,done support ya,maaf lewat.. 🙏🙏
@igorsmirnoff8578
@igorsmirnoff8578 Год назад
Будьте любезны,выложите такое же видео с прибором KEW 4106,спасибо!!!
@yusufsupyan9940
@yusufsupyan9940 4 года назад
Luar biasa kawan Videonya. Sudah saya kirim Bungkusan komplit dan,paten, durasipun Aman. Sesuai undangan. Ditunggu Amanahnya ya..
@rictorrictor888
@rictorrictor888 4 года назад
Ya udah juga..terima kasih..
@iranweranga225
@iranweranga225 Год назад
Is there a specific number of times that earth resistance testing should be done for a specific area? (like number of times per meter squard)
@ofwj-ddah
@ofwj-ddah Год назад
Thanls for sharingbthis video. It helps me a lots
@niezam1729
@niezam1729 3 года назад
Jika persekitaran rumah tamn agak sukar nk ambil bacaan,sb permukaan tanah @ berturap simen Dan jalan tar. 1- minutes 6.15 mase kita clamp wayar di electrod bumi.yg seeloknya copper tape @ cable incoming perlu ditanggalkan @ tidak semasa nak ambil bacaan.klu sye lihat Tuan x buka ..
@nasrulhelmeihalimppksistem7432
@nasrulhelmeihalimppksistem7432 3 года назад
kalau kawasan tar @ bersimen, boleh guna metal screen @ earthing mat. letak pada jarak yg ditetapkan & siram dgn air jd blh buat measurement
@Bestofthebest383
@Bestofthebest383 4 месяца назад
I had an exams question in college how to do earth rod test . I didn’t pass it 😢
@salumhongo3955
@salumhongo3955 Год назад
You demonstrate this critical task to look easily, Thank you very much a learn a lot through your video.
@muhdyunus3894
@muhdyunus3894 3 года назад
Video paling sng difahami...tq sgt2
@rjaramilloc
@rjaramilloc Год назад
Ese método no existe, tomaste medidas arbitrarias y sacaste un promedio... No tiene sentido.
@michaelisongekwere1402
@michaelisongekwere1402 Месяц назад
It was beneficial
@castertroycabillar2863
@castertroycabillar2863 3 года назад
Thanks for this very informative vedio. More power.
@CrisBoy410
@CrisBoy410 Год назад
video excelente parabens , abraços do Brasil .
@robertotrinanes1744
@robertotrinanes1744 2 месяца назад
What about the grounding rod resistance?each rod shall be tested and removed all connected cable before the test of total resistance grounding.
@mohamadasriabdulazid4784
@mohamadasriabdulazid4784 3 дня назад
Not really it depends on the situation and regulations of the country. We usually do it at the installation state, we check each time the rod is inserted to the earth. These guys in the video are doing inspection for application form.
@HENRYFANUELPHIRI
@HENRYFANUELPHIRI 3 месяца назад
Why the leads are in same line? pliz assist me sir.
@prabhus4137
@prabhus4137 2 года назад
Hi sir I have a doubt. Could you please tell me the difference between 2 point, 3 point method. In megger it has 4 terminals C1, C2, P1, P2. how to measure earth pit resistance?
@30mAkills
@30mAkills Год назад
Short C1 and P1 and connect to electrode under test. P2 is for potential and C2 is for current spike. This is known as 3 point or Fall of Potential method. 4 terminals method is for testing soil as per Wenner method. This is for civil guys and not for electrical guys. Reg 2 point earth pit resistance testing: In India we don't/cant use this method because our public water supply is thru PVC pipes which is non conductor. Hope this helps.
@lenslens7379
@lenslens7379 2 года назад
I think 1/RT = 1/R1 + 1/R2 + 1/R3
@SpecialVeloce
@SpecialVeloce Год назад
Sorry your Appying the wrong formula, it's average, not resistances in paralel
@ohhappyday1548
@ohhappyday1548 3 года назад
thanks to your efforts, it is very helpful .. thank you..
@azleeman
@azleeman 3 года назад
Saya nak tanya, bukankah testing dibuat semasa pemasangan rod sahaja (sebelum kita sambungkan dengan earth DB atau sebelum sambung ke perlindungan kilat)
@rictorrictor888
@rictorrictor888 3 года назад
Kedua2 nya boleh ..sebelum dan selepas ..Sebenarnya Cooper tape itu bukan utk pelindung kilat..
@kirotomato7316
@kirotomato7316 3 года назад
easy to understand,thank you sir for wharing the information for us
@kalamsa7445
@kalamsa7445 Год назад
Without much noise around, explained in a simple practical way...Thanks Rictor
@30mAkills
@30mAkills Год назад
Shifting potential spike towards right and left is wrong.
@MdSultan-u4e5t
@MdSultan-u4e5t Месяц назад
good
@kyoritsu7886
@kyoritsu7886 27 дней назад
Hello, this is Kyoritsu Japan. It is so honor that you used our product. We highly trust we can learn more from your excellence in feedback on electrical equipment. If you don't mind, we can contact via email.
@haseebali499
@haseebali499 11 дней назад
Great You from Kyoritsu Company Right
@PbaY.
@PbaY. 3 года назад
mantap tutorial nya .👍👍🌟🌟🌟
@MNor-nb8sp
@MNor-nb8sp 2 года назад
What we do if earth volt not zero
@rictorrictor888
@rictorrictor888 2 года назад
Find another location for grounding the rod..
@30mAkills
@30mAkills Год назад
De-energize that service and procced if the voltage is more than 10.
@aruniimalka6123
@aruniimalka6123 3 года назад
what is this aim?
@rictorrictor888
@rictorrictor888 3 года назад
Protect human and electrical equipment from electric short
@noelfaithfulkari2857
@noelfaithfulkari2857 Месяц назад
whats the meaning of 20ohms, 200ohms, and 2000ohms ?
@mohamadasriabdulazid4784
@mohamadasriabdulazid4784 3 дня назад
Earth Impedance/resistance. 20ohms is the range of that particular selection of the meter. If there is no reading in that range, we need to find it in the next range which is 200ohm range, and if still no reading needs to step up to the next range which is 2000ohm. Earth Impedance/resistance depends on the regulations of the country. For example my country only allows under 50ohm for residential areas, under 10ohm for public areas and under 1ohm for substation/transformers/high sensitivity industrial equipment.
@fazrulchanneltv9157
@fazrulchanneltv9157 2 года назад
Tq Sir. Clear and easy to undrstand. This place is like "Bukit Bendera" 😅
@rictorrictor888
@rictorrictor888 2 года назад
Yes bro..bukit bendera..tqvm
@foonglikwei3913
@foonglikwei3913 2 года назад
This teaching very useful and very easy to understand. Thanks and appreciate it 😊
@30mAkills
@30mAkills Год назад
Shifting potential spike towards right and left is wrong.
@ericmunkanta2964
@ericmunkanta2964 5 месяцев назад
Why is the leads in the same line
@solomonnyaga7018
@solomonnyaga7018 Год назад
Does it mean now the earth resistance is perfect?
@yghiduppastimatikelak8854
@yghiduppastimatikelak8854 2 года назад
Good job ...thanks for sharing..
@redbirdgaming7905
@redbirdgaming7905 3 года назад
Thank you very much sir Many Thanks
@daspecialist1220
@daspecialist1220 Год назад
Attack of the silent explanation vid strikes yet again
@rictorrictor888
@rictorrictor888 Год назад
Hahaha..Mr bean vers 2
@sanjeevraghav3700
@sanjeevraghav3700 Год назад
Appreciate 👌👌you have done share gr8 experience with kyoritsu instrument 💐 This is sanjeev raghav from kyoritsu
@rictorrictor888
@rictorrictor888 Год назад
Thank too .kyoritsu always the great equipment ..
@30mAkills
@30mAkills Год назад
This method is not FOP.
@callishandy8133
@callishandy8133 Год назад
Good country with laws and people that know a well earth ground safe tere life, reduce EMC, lower the body contact voltage, ... Wow well electrician = You controlled (only optical) the ground connection boxes around the house. For the beginning well done. I hope you measure the low resistance later to be sure that the connections are not corroded. Fine work und knowledge ! Well done. Attention your result is influence of the premium earth groundind metal in the earth. Keep the measuring line far away or you get worse results. 2.10 Ohm is very very low = perfect but in my country I start thinking why is it so low ? Where is the fault to get these brilliant results ? Very wet earth ? Under the measuring line = really no water pips, no powerlines, no other pipes/metallsheets , ... What is hidden under the bid concret by the 2nd Spike movement. Testing the earth voltage = well done you know the users manual ! Perfect We use different instruments in europe (english version form page 37 to page 72) www.dehn.de/store/f/27628622/EBA/1805_060583_GEOHM_Messger%C3%A4t.pdf And other brands. My thumb up for your video.
@MrOner07
@MrOner07 2 года назад
very easy to follow... you earned a subscriber!❤️😊
@30mAkills
@30mAkills Год назад
Shifting potential spike towards right and left is wrong.
@joselitodupaya2092
@joselitodupaya2092 3 года назад
Thank you sir sa video
@bruce.bchannel9046
@bruce.bchannel9046 3 года назад
Macam mna kalo erathing buat ats tnh bacaan bukit tu tnh...
@rictorrictor888
@rictorrictor888 3 года назад
tetap kena dapat kan bacaan bawah 10 ohm juga...tapi ada kaedah2 untuk menurunkan bacaan jika di buat atas tanah berbukit..tq
@bruce.bchannel9046
@bruce.bchannel9046 3 года назад
Sa lbih 15ohm bgtu
@bruce.bchannel9046
@bruce.bchannel9046 3 года назад
Nnti whatapps kmi 0138724857 mhu tnya kaedah lain
@rictorrictor888
@rictorrictor888 3 года назад
@@bruce.bchannel9046 boleh tambah point lagi tu..atau guna wayer tembaga bogel gulung jadi kan coil...tanam terus dlm tanah.hujung nya sambung ke electrod yang sedia ada..
@bruce.bchannel9046
@bruce.bchannel9046 3 года назад
Mcm mna cara ti
@dakwahislamcn6390
@dakwahislamcn6390 4 года назад
Lanjutkan
@marchomeautorepairs
@marchomeautorepairs 2 года назад
Keep up the good work
@angelosrcayabyab6952
@angelosrcayabyab6952 2 года назад
thanks for sharing
@fidelcatsro6948
@fidelcatsro6948 Год назад
if we had no access to such equipment will adding more grounding rods to the ground all connected together potentially reduce the earth resistance?
@rictorrictor888
@rictorrictor888 Год назад
Yes.
@fidelcatsro6948
@fidelcatsro6948 Год назад
@@rictorrictor888 🐱👍🏿
@nathan37141
@nathan37141 Год назад
Thank you Engineer
@قصيعليعبدالهادي
@قصيعليعبدالهادي 2 года назад
Thank you, sir
@kanthasamymuthusamy739
@kanthasamymuthusamy739 2 года назад
Simple explainations.Easy to underdstand
@30mAkills
@30mAkills Год назад
Shifting potential spike towards right and left is wrong.
@jillferrer6135
@jillferrer6135 2 года назад
thank you sir..
@bornstar9897
@bornstar9897 3 года назад
thanks
@william5624
@william5624 2 года назад
Very good👍🏻
@sahayaxaviersahayaxavier3217
@sahayaxaviersahayaxavier3217 3 года назад
Salute sir
@svh6195
@svh6195 3 года назад
Thanx!!
@japhethm6103
@japhethm6103 8 месяцев назад
What readings should tell me that the resistance is not okay please
@rictorrictor888
@rictorrictor888 8 месяцев назад
depend on local regulation ..as lower as possible. .below 10ohm
@roannapigkit261
@roannapigkit261 9 месяцев назад
@anthondiy
@anthondiy 2 года назад
Thank you sir sa video another learning for earthing system
@KGL101293
@KGL101293 2 года назад
Hi, I have a Kyoritsu 4105A unit too, and I am getting "1. . ." reading at 20 ohm dial, who do you think is the problem, and how to fix this? Thank you.
@deutroitcity
@deutroitcity 2 года назад
It's over limit. U need to dial up the limit. Cannot use 20ohm. Because the reading is above 20 ohm
@nasiadomary4893
@nasiadomary4893 Год назад
How about if the reading is 25ohms What can i do to get less than 5Ohms?
@30mAkills
@30mAkills Год назад
@@nasiadomary4893 1. If possible increase the depth of electrode. 2. Insert another electrode at a distance of at least twice the buried depth of 1st electrode and link both at top. Eg.: If 1 st electrode buried depth = 3 M then second electrode should be installed at a distance of minimum 6 M away and both should be linked with wire or strip at the top. 3. Wet the pit by watering because dry earth is a bad conductor. Note : Chemical electrodes are fraud work. Hope all this helps.
@nasiadomary4893
@nasiadomary4893 Год назад
@@30mAkills Thanks🙏🙏
@dumindathusuth2026
@dumindathusuth2026 Год назад
@thunderhype5972
@thunderhype5972 2 года назад
Sub
@johnherbster5110
@johnherbster5110 Год назад
Much too long. Can't stand the music. Should begin with the schematic drawings.
@fje1948
@fje1948 Год назад
Music is beautiful. If you don’t like the sound, turn the volume down! What an inappropriate comment!
@arturotakuma4742
@arturotakuma4742 Год назад
excelent ¡¡¡
@yosuaabimo9379
@yosuaabimo9379 9 месяцев назад
Test ini apakah harus saat listrik off?
@mohamadasriabdulazid4784
@mohamadasriabdulazid4784 3 дня назад
Kalau tak ada bocor ke bumi tak perlu off. Sebab tu dia check voltage dulu.
@castertroycabillar2863
@castertroycabillar2863 3 года назад
Sir what is the porpuse for higher ohms setting.is it same result as 20ohms setting.thanks
@rictorrictor888
@rictorrictor888 3 года назад
Yes..same.
@30mAkills
@30mAkills Год назад
For soil testing and also in hill areas.
@wilsonloo8576
@wilsonloo8576 3 года назад
Hi Rictor , may i know how to know the result is good or bad? Many Thanks
@rictorrictor888
@rictorrictor888 3 года назад
low in reading is the batter .must below 10ohm.some time we can get 0 ohm. that the best..
@octaviohurtado2779
@octaviohurtado2779 3 года назад
It depends on your country standards. But the Best is the nearest to 0 ohms which is imposible to get 0 ohms. Also there are many methods to make the measurraments, it depends on your country standards too.
@islammaidul6999
@islammaidul6999 2 года назад
Overall resistance how is it calculation sir
@rictorrictor888
@rictorrictor888 2 года назад
Total of test 1 ,2 ,3 then / by 3..it show on video min 13.20
@leomarbecilla2785
@leomarbecilla2785 2 года назад
hi sir. how do you perform it in a building where there is no earth ground to put the spike?
@rictorrictor888
@rictorrictor888 2 года назад
Extent green wire..
@rictorrictor888
@rictorrictor888 2 года назад
For condo there should have main electrical grounding
@johnhayhurst5884
@johnhayhurst5884 3 года назад
Very Very different to how it's done in the UK, In the UK those reading wouldn't be satisfactory but the method is way different so I don't know. Interesting though
@azleeman
@azleeman 3 года назад
Maybe the humidity in UK is different if we compare to Malaysia. The water in soil can effect the meter reading.
@nasrulhelmeihalimppksistem7432
@nasrulhelmeihalimppksistem7432 3 года назад
@@azleeman biasanya ada 2 jenis earth tester yg selalu diguna measure grounding resistance. yg dlm video ni guna kyoritsu & location potential spike tu ditengah2 antara ground rod & current spike. yg satu lg jenama megger tapi jarak potential spike tu 62% dari jarak antara earth rod & current spike. & potential spike tu kena ubah 10% ke depan % 10% ke belakang dari kedudukan asal & diambil average dr 3 reading td. mungkin kat uk guna jenama megger sbb tu dia ckp different dgn kt sini.
@30mAkills
@30mAkills Год назад
All over the world FOP (Fall of Potential) method is same.
@johnhayhurst5884
@johnhayhurst5884 Год назад
Incorrect@@30mAkills
@30mAkills
@30mAkills Год назад
@@johnhayhurst5884 then tell the correct. Here our earthing is TT.
@junsmackalbos4565
@junsmackalbos4565 Год назад
Sir the result you shown is that good or bad grounding
@rictorrictor888
@rictorrictor888 Год назад
Good ..under 10 ohm
@junsmackalbos4565
@junsmackalbos4565 Год назад
Thanks sir......
@stanleyozoilo1587
@stanleyozoilo1587 Год назад
What is the accurate value for best low resistance using Megger machine
@rictorrictor888
@rictorrictor888 Год назад
0 ohm
@30mAkills
@30mAkills Год назад
@@rictorrictor888 Practically not possible. Is earth full of gold?
@fje1948
@fje1948 Год назад
@@rictorrictor888 I wish 😂
@TheElectricianOnHisMission
@TheElectricianOnHisMission Год назад
I have to perform this same test but outside of the building is all concrete, a shower room will be built in the basement but first the neutral to earth voltage needs to be tested, so how would I go about this?
@frankkennedy7831
@frankkennedy7831 Год назад
you silly person. what sort of system are you on?
@30mAkills
@30mAkills Год назад
Check with normal clamp or multimeter in volts mode between earth and neutral of any 3 pin socket connected to that service. The voltage value should be below 2. Hope this helps.
@fje1948
@fje1948 Год назад
@@frankkennedy7831 Perhaps you are the silly person making such an inappropriate comment! 🤢
@nagarajah8930
@nagarajah8930 25 дней назад
Sir ummmmmmmmmmbu
@gabus1956
@gabus1956 2 года назад
Thank from Hungary
@30mAkills
@30mAkills Год назад
Shifting potential spike towards right and left is wrong.
@siralexivan2006
@siralexivan2006 3 года назад
well done
@rictorrictor888
@rictorrictor888 3 года назад
Tqvm
@wtnyambizi9876
@wtnyambizi9876 2 года назад
What about the distance btn the spikes does it matter !?
@anthonykihanga2881
@anthonykihanga2881 Год назад
5 meters up to 10 meters it depends on soil type
@30mAkills
@30mAkills Год назад
Thumb rule for current spike distance from electrode = Minimum 8 to 10 times the buried depth of earth electrode. Eg., If earth electrode is 3 M long then C spike should placed about 24 to 30 M distance. This is to avoid '"zone of influence"' factor. Most manufacturers wont tell this because the distance will affect their tester sales in city and town areas where space is congested. So they suggest 5 M and 10 M which will not yield correct value. I challenge Kyoritsu in this matter.
@fje1948
@fje1948 Год назад
@@30mAkills Thank you for this comment - can you please provide some formal references to confirm y you our comment - Thank you!
@anthonykihanga2881
@anthonykihanga2881 Год назад
Thanks alot
@30mAkills
@30mAkills Год назад
Shifting potential spike towards right and left is wrong.
@surendrakverma555
@surendrakverma555 Год назад
Good 🙏🙏🙏🙏🙏
@30mAkills
@30mAkills Год назад
Shifting potential spike towards right and left is wrong.
Далее
Earth Electrode Testing
14:16
Просмотров 503 тыс.
What is Earth Resistance? How to measure it?
9:10
Просмотров 27 тыс.
ХОККЕЙНАЯ КЛЮШКА ИЗ БУДУЩЕГО?
00:29
Earthing vs. grounding
7:06
Просмотров 117 тыс.
Earth Electrodes - 3 Wire Testing Example (Part 3)
19:10
Earth Electrodes Part 1
11:48
Просмотров 100 тыс.
Earth loop impedance test, ZE test
4:56
Просмотров 68 тыс.
Earth electrode testing the proper way
23:40
Просмотров 13 тыс.
Loop Impedance Testing
15:04
Просмотров 290 тыс.
ХОККЕЙНАЯ КЛЮШКА ИЗ БУДУЩЕГО?
00:29