How to properly connect the Dyness DL5.0C battery with the Deye inverters 

Dyness
Подписаться 46 тыс.
Просмотров 3,5 тыс.
50% 1

Опубликовано:

 

24 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 9   
@kinikalex7044
@kinikalex7044 11 часов назад
Do i have to install circuit breaker?
@JayChishimba
@JayChishimba 13 дней назад
hi I have a problem with the with this battery I installed it with the must inverter the aram is go on at the battery why
@DynessBattery
@DynessBattery 12 дней назад
Hello, where are you from, I will send you the email of the region technical engineer.
@ArdZolox
@ArdZolox 2 месяца назад
Hi, can you help me with this product? I have two A48100 batteries installed, the label on each says "Max. discharge power 3.6 kW". I assumed that with 2 batteries installed, I can draw power of 7.2 kW, but when my load exceeds 3.6 my inverter soon shuts down the power completely and sometimes shows error F56 (DC_VoltLow_Fault). Does this mean the batteries are not installed/configured properly, or is this expected behavior?
@ArdZolox
@ArdZolox 2 месяца назад
P.S.: the inverter is Deye SUN-12K-SG04LP3-EU, battery setting menu is configured as "Batt Capacity 200Ah , Max A Charge 100A, Max A Discharge 200A". But Li-BMS menu shows "Charge Current limit: 0A, Discharge Current limit: 50A".
@DynessBattery
@DynessBattery 2 месяца назад
In communication mode, the maximum continuous discharge current of the two batteries is 100A. According to your system information, there is an abnormality in the communication between the batteries. The DIP switch of the host battery is set to 0010, and the slave battery is set to 0000.
@ArdZolox
@ArdZolox 2 месяца назад
@@DynessBattery Thanks. Just in case someone else needs help and reads this, DIP jumper on the slave battery was indeed in a wrong position. Plus, the connection between batteries was done via (battery inverter) cable. When I replaced it with a common Ethernet patchcord, my Discharge Current limit became 100A in Li-BMS screen.
@FuriousDin
@FuriousDin 2 месяца назад
hello what is charge limit for x2 Dyness DL5.0C ?
@DynessBattery
@DynessBattery 2 месяца назад
Hello, can you tell me the model of your inverter? This is also related to the inverter.
Далее
Dyness B51100 огляд і тест
10:06
Просмотров 5 тыс.
БЕЛКА РОЖАЕТ#cat
00:19
Просмотров 1,2 млн
skibidi toilet 77 (part 3)
04:51
Просмотров 14 млн
Pytes: you get what you pay for
13:28
Просмотров 23 тыс.
New Dyness Solar Energy System with Orion Battery
8:02
Dyness B4850 units connect with Luxpower off grid unit
14:57
How to make parallel connection for lithium battery?
11:20