In this video, I will show you how to rough in plumbing under a slab for a bathroom, and I've made sure it's beginner DIY friendly! Whether you're tackling a DIY bathroom renovation project or simply curious about the process, this step-by-step guide will give you the knowledge and confidence to handle the plumbing aspect of the job. Watch as as I explore the essential tools, materials, and techniques needed to successfully rough in plumbing under a concrete slab. From marking out the layout and digging the trenches to installing drain lines and vent pipes, you'll learn it all. By the end of this video, you'll have a solid foundation of plumbing knowledge to build upon and take your bathroom project to the next level. This is part 3 of Garage Build Series.
My Favorite Tools And Supplies 👉 www.amazon.com/shop/theexcell...
Tools And Supplies Used In This Video👇
Clean-Seal 3" Test Plug amzn.to/42C0m4c
Metal Reciprocating Saw Blades amzn.to/41y9ViW
Heavy Duty PVC Cement amzn.to/42wIpUk
Purple Primer amzn.to/41smtsd
Metabo Miter Saw amzn.to/3I5m2Nw
More Helpful Related Videos👇
Build A Garage Playlist • Build A Garage
How To Plumb A Bathroom In 20 Minutes! - Beginners Guide • How To Plumb A Bathroo...
How To Rough In Plumbing Under A Concrete Slab • How To Rough In Plumbi...
Metabo 10" Miter Saw Review • Metabo HPT 10” Miter S...
🟢 Become a channel member:
/ @theexcellentlaborer
🔴 Subscribe to this DIY channel: ru-vid.com...
🔵 Subscribe to my personal finance channel: ru-vid.com...
🟡 Check out my Amazon store: www.amazon.com/shop/theexcell... . Here you will find tools and supplies used in my videos. (DISCLAIMER- I am an Amazon affiliate. I get a small commission that helps support the channel at no extra cost to you)
Timestamps
Intro 00:00
Plumbing Layout 00:20
Clean Out Tee 05:13
3" to 1 1'2" Reducing Combo Wye 08:10
Proper Sloping 11:57
Laying 1 1/2" Pipe To Sinks 12:26
Laying 3" Pipe To Toilet 19:00
3" Combo Wye 21:08
3" Elbow For Vent 22:35
Test Plug Installation 23:45
Hydrostatic Testing 24:51
Backfilling 27:17
Disclaimer: This video is all based on my personal opinion and is for entertainment purposes ONLY. I am not a financial advisor, CPA, attorney, tax advisor, electrician, plumber, housing contractor, designer, or any type of profession to give advice. I am just a consumer sharing my experiences and research. If you do need knowledge for those types of things, I will advise you to seek help for those professionals.

Хобби

Опубликовано:

 

14 июн 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 222   
@tillisross2246
@tillisross2246 9 месяцев назад
I really appreciate the extra time you’ve taken to teach all of us.
@TheExcellentLaborer
@TheExcellentLaborer 9 месяцев назад
You are very welcome! I love making these videos and sharing them. Thanks for being a part of the community!
@alfonsoaguilar9612
@alfonsoaguilar9612 Год назад
THE #1 Most completely fully detailed underground rough plumbing video on RU-vid. You deserve an award for this one. I’m about ready to start my ADU and Jr ADU project, just waiting for plan corrections 1 review. This video is AWESOME!
@louisel.sinniger2057
@louisel.sinniger2057 Год назад
Excellent job, clean, organized. Speaks volumes for your work. Great instructions.
@slickwilly6868
@slickwilly6868 6 месяцев назад
My pops is a master plumber and contractor out of Arkansas. I been around plumbing my whole life, and he always told me to do a quarter turn every time you glue a fitting on a pipe to push the air out.
@whirlwindjml
@whirlwindjml 26 дней назад
7:40
@royvoth5366
@royvoth5366 Год назад
I am a carpenter,I love watching videos on building, your videos are very well explained,when I started in this business,I wish I could have worked with someone like u,your a very good teacher,thanks for your time...
@davidharrison3074
@davidharrison3074 Год назад
It is always fun to do drain work as well. On my jobs with remodeling, I'd have some kids that would see my tote containers and say it looks like tinkertoys and want to play with all the pieces. Using a chop saw is really nice even on three and four inch schedule 40. Rolling the pipe if it wouldn't cut all the way through works as well. In our area, it's okay to have a clean out extended up after the inspection and the test plug was removed and would be checked on the final inspection. As always each area is different with codes. Using purple primer is liked in our area as well because it shows the fittings were primed too. Nice clean job and the back filling done really well. So important to make sure you fill under the pipes and making them secure and holding the fall as well. Thank you for all the details even with using tapcons to hold your lines. I find it just as easy since I have the tools to do it on hand. Great Job Josh 🔨👍🏻
@TheExcellentLaborer
@TheExcellentLaborer Год назад
Oh yes, that’s a good option to have the clean out extend up. In this case it would be right in the bathroom and I did not want to have that in the middle of the floor. If I have to snake the plumbing , I can just go through the toilet drain. We must use purple primer here as well to show proof that primer was used. It is amazing how every coding is different in different areas. The tap con trick works well and can place the string lines back on the block before I pour the concrete to make sure they are still perfectly in place. As always, thanks for the detailed comment David! Take care!
@Box545x39
@Box545x39 10 месяцев назад
I hope you get a mil subs soon, you make the best videos to follow along with. No detail missed, and a wealth of knowledge.
@albertstrong5516
@albertstrong5516 Год назад
Excellent job. Always great to see a professional at work.
@TheExcellentLaborer
@TheExcellentLaborer Год назад
I appreciate that Albert! Good luck with your projects, and take care!
@rickyswanson8547
@rickyswanson8547 Год назад
Vague description of "Professional"
@ENTREPRE-MOMMY
@ENTREPRE-MOMMY Год назад
Thank you for this! I'm moving over to building from fix and flip. This came right on time.
@TheExcellentLaborer
@TheExcellentLaborer Год назад
Very cool! In my area building seems to be more profitable than flipping. So I understand your decision. I hope you can get some pointers from this video. Good luck with your endeavor!
@Rob-fp3xq
@Rob-fp3xq Год назад
Love your videos! Learned more from your videos than any book.
@TheExcellentLaborer
@TheExcellentLaborer Год назад
Videos of powerful media source to learn online. I’m so thankful I can help Rob. Thanks for watching!
@kennethmarable9471
@kennethmarable9471 11 месяцев назад
This Video was EXCELLENT and very easy to follow. Teaching is a Skill 👏👏. I will definately sign up for all your videos. 👍
@winterfar2814
@winterfar2814 Год назад
Great video man. Doing UG plumbing for my basement and this helped me out.
@Ronthewoodguy
@Ronthewoodguy 4 месяца назад
This wall very well explained and excellent tutorial. Thank you
@Leviathan092
@Leviathan092 8 месяцев назад
Appreciate the video, in school for plumbing and myself and a couple other good students were starting a rough in and didn't quite see the full picture yet.
@leviconti6907
@leviconti6907 5 месяцев назад
I'd have a good day working with this guy! Easy going, explains in an easy way.very knowledgeable .
@TheExcellentLaborer
@TheExcellentLaborer 5 месяцев назад
Thanks Levi! I’m glad you like my content!
@ThomasAtito-zw5ne
@ThomasAtito-zw5ne 10 месяцев назад
Am a beginner and I hope this channel will help me thank you
@GS.9093_Mart
@GS.9093_Mart Год назад
Pretty awesome to see this as I just started my plumbing journey last week. Thanks for sharing
@TheExcellentLaborer
@TheExcellentLaborer Год назад
Congratulations on your new journey! I have always done plumbing in my own houses and kudos to you for doing what you’re doing. It’s amazing how much more lucrative trade jobs are then there’s jobs these days. Keep me informed with how everything is going! You are welcome!
@bobbyosborne2375
@bobbyosborne2375 8 месяцев назад
I hope the journey didn't begin in Kentucky because EVERYTHING this guy installed would be INCORRECT and ILLEGAL in my state.
@dailytricks6161
@dailytricks6161 Год назад
Good luck and peace to whoever is reading this! You did a great job! Thank you, wish you health and success!☺️
@charliefraser793
@charliefraser793 7 месяцев назад
I love plumbing its such good trade very fun
@matthewlassise7607
@matthewlassise7607 8 месяцев назад
Very good job on the plumbing underground I like it!
@Jon-lv8dc
@Jon-lv8dc 11 месяцев назад
Seriously thank you for this video. You did an awesome job explaining this stuff.
@TheExcellentLaborer
@TheExcellentLaborer 11 месяцев назад
You’re welcome John. I always enjoy doing my own plumbing work. I hope the video helps you. Take care!
@codyp3041
@codyp3041 8 месяцев назад
This man is good at plumbing
@daviddunn1923
@daviddunn1923 8 месяцев назад
Excellent, excellent video, Excellent Laborer!
@edardon16
@edardon16 Год назад
Thank you for this Excelent video.
@gregsatterly9412
@gregsatterly9412 10 месяцев назад
In the state where I live you can't use 1 1/2 underground. When I did groundwork as a plumber we used regular schedule 40 pvc. I am building a house now. I had to catch a kitchen, laundry room, and 3 bathrooms. That was some serious piping!!! I used a mini excavator to dig for my lines.
@richt2633
@richt2633 3 месяца назад
Great Video! I like it…”Glueing and Going”. 👍
@CivilianDan
@CivilianDan Год назад
Learned something new. Thank you.
@TheExcellentLaborer
@TheExcellentLaborer Год назад
Glad I can help. Thanks Civilian Dan!
@markchriestenson3257
@markchriestenson3257 7 месяцев назад
Great tips for some of us novice dyirs
@tehapu7358
@tehapu7358 11 месяцев назад
Excellent video dude, you're a hard worker.
@TheExcellentLaborer
@TheExcellentLaborer 11 месяцев назад
I appreciate that! It is a lot of work, but rewarding, so it is worth it to me. I hope everything is going good with your projects. Take care!
@trevorabeel6102
@trevorabeel6102 5 месяцев назад
Bro, forget that guy that was the most informal video. I've ever seen. you covered every base. And I hope you got more trades up your sleeve. Keep the videos coming u got a sub in me.
@javiermorales301
@javiermorales301 2 месяца назад
Good video very detailed thank you!
@allisonbowen7445
@allisonbowen7445 Месяц назад
Very informative.
@israelnemitz8323
@israelnemitz8323 9 месяцев назад
Your videos are awesome!
@alexis_dc2
@alexis_dc2 9 месяцев назад
Watching this while 💩 and seeing what will happen when I flush the toilet 🚽. Great job btw!!!
@chilledvibez5799
@chilledvibez5799 11 месяцев назад
First, I'll like to say thank you! for this type of content you put out there for us rookies, DIY's or youngsters like me who's freshly entering the trade, Ton of respect for your skill and work! Your ability to switch between wiring,plumbing,framing it's insane! I wanted to ask how is it possible to get the best of both worlds being a carpenter but also having an interest for plumbing? I'd like to switch between both but an apprenticeship forces me to commit to one. Love to hear your insight on this, Thanks!
@williamhanna5224
@williamhanna5224 Год назад
Great work!
@TheExcellentLaborer
@TheExcellentLaborer Год назад
Thank you, William!
@robertmungenast4193
@robertmungenast4193 Год назад
I enjoy your videos keep up the good work.
@TheExcellentLaborer
@TheExcellentLaborer Год назад
Thanks for letting me know Robert! I love seeing subscribers like you coming on my videos. It means a lot. Take care!
@jdonez8347
@jdonez8347 3 месяца назад
Hell yea josh appreciate the tips, interested in building myself a single apt/30x30 shop setup....
@HomeImProveMentHow
@HomeImProveMentHow Год назад
*Josh, I just read your About Section, I started my channel to make a difference,* in helping Others wanting to learn as well, Although I don't know everything, It's good to see someone else of the same mindset and I look forward to hear from you by for now Ken
@TheExcellentLaborer
@TheExcellentLaborer Год назад
Yes, I certainly don’t know everything either. I do like to share what I do when it comes to building. Thanks for watching!
@spreadcreekjr1731
@spreadcreekjr1731 Год назад
Love these videos
@TheExcellentLaborer
@TheExcellentLaborer Год назад
Thank you so much! I hope you find them helpful. Take care!
@ubaldohernandez5016
@ubaldohernandez5016 9 месяцев назад
Excelente!!
@winterfar2814
@winterfar2814 Год назад
For anybody watching this you do not have to use solid core PVC for residential application. Foam core PVC is perfectly fine for a normal single-family home with normal soil. If you had unstable soil and you were having to suspend the piping from the structural slab, then you would need to use solid core PVC, if not and you just have a normal situation 4 inch concrete, 4 inch layer of wash stone foam core PVC is perfectly fine. This is coming from a plumbing designer and also confirm with Charlotte pipe and foundry. There’s a huge misconception here with people thinking they need pressure rated piping is simply not true from an engineering standpoint it’s a unnecessary expense. However, this is a great video, and I actually learned something from a plumbing construction standpoint.
@Macktrucking
@Macktrucking Год назад
Amazing work I just subscribed
@TheExcellentLaborer
@TheExcellentLaborer Год назад
Thanks! Enjoy the content!
@louismaberry9683
@louismaberry9683 Год назад
Awesome!
@TheExcellentLaborer
@TheExcellentLaborer Год назад
Thank you. I appreciate that!
@aptpupil
@aptpupil 5 месяцев назад
Well done thanks
@TheExcellentLaborer
@TheExcellentLaborer 5 месяцев назад
No problem 👍
@Refinerii
@Refinerii Год назад
Great stuff
@TheExcellentLaborer
@TheExcellentLaborer Год назад
Thank you Amber!
@MarvinGuzman-ym7yo
@MarvinGuzman-ym7yo 7 месяцев назад
Been plumbing for 4 years. Very helpful video. Thanks
@user-xl7fo7ww5r
@user-xl7fo7ww5r 8 месяцев назад
Good teacher indeed,am still a plumbing student,it could be better if I can reach you sir
@joecox9958
@joecox9958 7 месяцев назад
Thanks a lot! How do you consider vapor/insulation for slab? glad to see, My city inspector asks water level above roof for leak test. such traditional slab sewer is so hard to repair and I will never use it - Use sunken slab with tunnel for pipes. Thanks a lot! For vent through concrete block, you get to cement it first. For clean out, you get to leave it out some where - I don't think it can be used as clean out.
@ecuadordave8076
@ecuadordave8076 14 дней назад
Good video. A few things that I know dont work for Florida code ( there quite particular down here.) ANyway, did you by chance have a video to show any hacks on how to layout the initial lines to measure your future walls and such.
@user-bz2eu8rh2r
@user-bz2eu8rh2r 2 месяца назад
thank you for sharing sir. i've learned a lot. how can i have a test balloon?
@Kanesgarage
@Kanesgarage 11 месяцев назад
A lot of work. Makes it seem so easy to split underground years down the road
@joshuagreen9458
@joshuagreen9458 8 месяцев назад
not picking on you. just helping with more info. 2 inch pipe is the smallest one should use underground. horizontal dry vents are illegal so if you turned that vent into a wall cleanout it would make it legal. also idk if your walls are wood or cmu but if they were wood you wouldnt need to run a drain line for your lav because you could dirty arm off that vent in wall less piping underground the better. also not just deburing pipe but you should ream it with a reamer. there is videos out there that will show you why you should ream it. you should do ten feet for head pressure when you fill your pipe for the hydrostatic test. i will say as someone who does this for a living you explained it very well. probably the best ive ever heard. the application is great. keep in mind i understand we all have different codes in areas. ours code does not allow foam core in the ground.
@joshuagreen9458
@joshuagreen9458 8 месяцев назад
also for someone who is a beginner i would run string lines for both sides of all your walls. it doesnt take much longer and you wont forget which side of the string you need to be on. just another one of those prep steps that make a huge difference.
@eddieesco2432
@eddieesco2432 3 месяца назад
You can bury 1.5 pipe for tub trap arms and traps
@user-dx7ky6qc4v
@user-dx7ky6qc4v 5 дней назад
No u shouldn't use foam core I hate it plus I agree I would only put 2 inch underground.inch and half is to small.
@plumbbuild6517
@plumbbuild6517 8 месяцев назад
You did a great job with the plumbing, the only thing I do differently is I never run 1 1/2 underneath concrete I always size up to 2” but code let’s you use 1 1/2 but me being a service plumber aswell I’ve have seen more blockages in 1 1/2 pipe than 2” pipe. But great job it looks very professional.
@TheExcellentLaborer
@TheExcellentLaborer 8 месяцев назад
I appreciate that! I really do enjoy plumbing. I found a very interesting how you can bring water in and take waste out in a controlled environment. Thanks a lot for your input on this video. Thanks for watching!
@jerrynorris1397
@jerrynorris1397 7 месяцев назад
I totally agree about the 2 ins. Drain pipes
@bhenderson1674
@bhenderson1674 2 месяца назад
@bruhen361diverI have a toilet that has always almost overflowed, swirled very slowly, then drained slowly, barely emptied if at all, then the bowl slowly refilled or only filled enough to keep gasses from coming past the throat opening. I finally removed the toilet, put a cell phone camera on a stick and found that the 3" pipe has a 90 degree elbow (not a sweeper, but a vent elbow). I tried snaking the drain, but it will only make the turn and another few inches until out of sight. When I tried to wiggle it to help out, I heard water splashing. Do you think replacing the toiled with one which has the Sloan "Flush Mate" valve or am I looking at busting up the slab?
@guven1001
@guven1001 4 месяца назад
Thank you for the very detailed video. I have a question: around the 21:14 mark on your video when your 3" toilet pipe is running toward the street there is a 2" downward pipe I am guessing that is an air vent or some vanity drain pipe. Isn't it against the plumbing code to have that way where the toilet waste could get into that 2" pipe? Thanks!
@grizzman1991
@grizzman1991 6 месяцев назад
nice job only thing i would have done different is increased the the 1-1/2 to 2 inch and the 3inch to 4... I always oversize under a slab!!
@WhispersFromTheDark
@WhispersFromTheDark 3 месяца назад
Josh, I've been watching your videos and actually taking notes (not joking) and I appreciate how detailed you are with explaining what you're doing and why, that is very useful information. I have a problem that I hope you can help me with. I will be building an apartment inside an existing metal garage that already has a concrete floor and I'm stumped at how I can run the slopes for the waste drains at the appropriate 1/4" per foot recommendations, without having to cut into the concrete floor. Other than building the floor up a foot or more, I'm at a loss on finding my options. I have looked everywhere for a video that shows someone installing plumbing on top of their existing concrete. I don't want to cut into the concrete, so what options do you see that I have? I will be doing most of the build myself so easier is always better for me. I'm old, I have a spinal injury and will be working on this on weekends going paycheck to paycheck. Thanks again for all that you do in helping us understand things while we build our dreams.
@kevintheplumber3729
@kevintheplumber3729 6 месяцев назад
Good stuff. I can say though, as others have, about the 1 1/2 pipe. 2" minimum. Acutally, i think our local codes forbid 1 1/2 under slabs and definitely 3" under slabs. They are only allowed if there is a crawl space.
@richt2633
@richt2633 3 месяца назад
Great Video. Can you (or someone) direct me to info on free-standing tub rough-in before pouring concrete? Specifically the filler kit, the slab is the finished floor. Thnx again!!
@SB-dg8hq
@SB-dg8hq 2 месяца назад
In the UK we would only install the 4" pipe so that toilet drain and the drain for the sink would go into the same pipe above ground. We would not run a small diameter pipe underground. There would be a water trap under the sink to prevent smells from coming up from the drain.
@gbpg2016
@gbpg2016 2 месяца назад
So how do you get the toilet flange on once the concrete is laid? Do you remove it around the pipe before it cures?
@HomeImProveMentHow
@HomeImProveMentHow Год назад
What state are you in? *👍🏻... Excellent job on being Thorough.* Thanks for sharing I look forward to hear from you bye for new friend Ken
@TheExcellentLaborer
@TheExcellentLaborer Год назад
You’re welcome, Ken thanks for watching!
@RH-cv1rg
@RH-cv1rg 6 месяцев назад
Don't you have to wrap the pipes where they touch poured concrete, like when they fill the foundation walls or thorough the slab floor?
@dregs8026
@dregs8026 2 месяца назад
I have a dumb question for you. How are you able to dry fit the fittings without glue that helps slide it tight into place? I find that when I dry it fittings they fit totally different when I add the glue.
@JROD659
@JROD659 2 месяца назад
is the pipe with red and blue just going down into the dirt ?
@cashcow4383
@cashcow4383 4 месяца назад
Do the pipe have to be set at a certain angle?
@jermainedorsey2397
@jermainedorsey2397 Год назад
How are you going to clean out your drains in it ever gets clogged there’s no clean out drain?
@jasondeleon5511
@jasondeleon5511 11 месяцев назад
What app do u use for your drawings. By the way, I’ve learned a lot from your videos. You explain very thoroughly. I have run all my electrical and did the PEX plumbing, and ventilation for my mini house, with the help of your instructional videos. I could use this app for my drawings, on future projects.
@TheExcellentLaborer
@TheExcellentLaborer 11 месяцев назад
The app is Freeform on Apple products. Sounds like your mini house is going well. Good luck with the rest of your house. Take care!
@jasondeleon5511
@jasondeleon5511 11 месяцев назад
@@TheExcellentLaborer thank you sir. It’s coming along.
@okkrom
@okkrom Год назад
Bi-metal refers to the sawzal blade itself. Basically means they use 2 types of metals, some hardened high carbon for the teeth and softer metal for most the blade. But I get your point,; using a blade designed to cut metal works best indeed.
@dancampbell972
@dancampbell972 4 месяца назад
For Drain you used PVC -- is ABS not allowed?
@user-sf3jm4eq9h
@user-sf3jm4eq9h 5 месяцев назад
I apologize in advance if this is a stupid question, but when you laid out the walls in the beginning of the video and figured 4 foot 6 inches. Did you know that by a scale from the drawings? I see the stairs and the wall but I am not quite sure how you knew it would be 4 foot 6.
@neilsolano8874
@neilsolano8874 11 месяцев назад
Are the fittings that special solid pvc like the pipes. Or are they cell core? I never knew there were two types of schedule 40 pvc types so just wanna make sure there’s diff type fittings as well?
@javankuusisto6614
@javankuusisto6614 11 месяцев назад
All fittings are solid
@GoneCoastal544
@GoneCoastal544 10 месяцев назад
Just curious, why did you install the test tee under the slab rather than outside where it could be used as a cleanout in the future? Great work love the videos just curious about that.
@JacobGluck
@JacobGluck 9 месяцев назад
Test tee cannot be used as cleanout. However he could have installed a two way cleanout outside and used that to test.
@edwardmccoy274
@edwardmccoy274 8 месяцев назад
You can use that test tee as a clean out, put a four inch male adapter and a riser on it...
@GoneCoastal544
@GoneCoastal544 8 месяцев назад
@@edwardmccoy274 but then it is inside the wall or on the floor of the interior of the building. It makes way more sense to put it on the other side of the wall, either way you have to attach a adapter and riser plus cap.
@JK-mh3ld
@JK-mh3ld 4 месяца назад
I am planning a bathroom project in a building with a slab that has never been plumbed for anything. I would like to run the drain line from toilet, shower, and vanity above the concrete and exit the building out through the back wall with - one drain line. Basically, build a 10' X 10' floor, run lines to wall with no cutting into the concrete slab at all. Most videos show chopping out the cement and repouring. I can't find one that does it the way I describe. I would welcome any thoughts anyone has on this plan. I am concerned about over all gravity drop once the drain clears the building. Thank you
@robertgries5326
@robertgries5326 Год назад
What software application did you use to draw your plans?
@TheExcellentLaborer
@TheExcellentLaborer Год назад
Freeform. It is on Mac. I hope that helps!
@danielsmithson4870
@danielsmithson4870 10 месяцев назад
I would like to know if I can buy the software you used to design your plumbing. If I can, then maybe you could pass on the make and model and I can search for a vendor for on the internet.
@FlipNasty1
@FlipNasty1 5 месяцев назад
Wrap your toilets with a foam wrap (2 " thick around) right where the concrete foundation😢 will be poured...so in case they move during the backfill you can just slap an offset flang instead haveing to chip up concrete to get your toilet in the right spot
@tannerwest6823
@tannerwest6823 Год назад
For inspection,you don’t have to have a 8-10 ft tall stand pipe for head pressure when testing the drain lines? Here in NC they want that
@tehapu7358
@tehapu7358 11 месяцев назад
Everywhere they want that. UPC.
@tannerwest6823
@tannerwest6823 11 месяцев назад
That’s what I figured. Must not care wherever he’s at. The pipe he used to fill up the system was no more than 4 ft tall
@codyp3041
@codyp3041 8 месяцев назад
I am currently working with the worst plumber I have ever met. This is refreshing to see.
@dennisbrown2844
@dennisbrown2844 4 месяца назад
Not being out of the way cause I appreciate what you do, but in my southeast region of the US 2 inch is the smallest pipe you can use underneath a slab.
@jamessprow7116
@jamessprow7116 Год назад
We are not allowed to go in a smaller than 2 inches underground here in Michigan or Kentucky
@she219
@she219 10 месяцев назад
If you're a contractor...I would love to work with you... Nice 👍🏾💯 and clean plumbing
@Eelavatiionz
@Eelavatiionz 7 месяцев назад
Why not just put your level right on the pipe as you glue it instead of dry fitting and making a mark? Saves you so much time
@stormbytes
@stormbytes 9 месяцев назад
@16:00 You're suing a long sweep 90 vertically to tie into your horizontal line. Pretty sure you need to use a combo wye (directionally) for that connection.
@rjz9465
@rjz9465 8 месяцев назад
No
@Striker-tq4vf
@Striker-tq4vf 11 месяцев назад
Is the vent pipe schedul1 40 pvc? Or is it a different material?
@TheExcellentLaborer
@TheExcellentLaborer 11 месяцев назад
It is schedule 40 as well. I hope that helps!
@Striker-tq4vf
@Striker-tq4vf 11 месяцев назад
@@TheExcellentLaborer Thank you! Also, is it called "vent" because it goes through the vent on the roof to access the outside?
@terrencesalvida7545
@terrencesalvida7545 10 месяцев назад
Electrical and plumbing in the same conduit? That’s a first for me.
@jessesilver
@jessesilver 9 месяцев назад
That's not what he did.... He mentions at the end he just tucked the open end of the PEX into the other conduit to hold it there, but in reality one conduit is PEX and the other is electrical wire.
@jeffdeluca1153
@jeffdeluca1153 Год назад
I see you used Heavy Duty cement for the PVC. I just plumbed a bath (not subfloored yet) and used the Medium Duty (which the can says it suitable for 4" and less. Did I make a booboo? Thx again
@TheExcellentLaborer
@TheExcellentLaborer Год назад
Medium PVC cement should be good up to 6 inches I believe. It depends on the manufacturer, of course. Be sure to reference the manufactures recommendation. Hope that helps!
@jeffdeluca1153
@jeffdeluca1153 Год назад
@The Excellent Laborer Hey thanks. I just looked and actually used Regular cement, which is good for up to 4" . My max is 3"/toilet and 1 1/2" for the sink and tub. According to the can it should be good.
@jacksonnra1856
@jacksonnra1856 Год назад
Your application is a non pressurized one. Primed and glued,you'll be fine.
@samlouie7754
@samlouie7754 8 месяцев назад
What app did you use for your drawings?
@TheExcellentLaborer
@TheExcellentLaborer 8 месяцев назад
Freeform. It’s an Apple app. I hope that helps!
@steveh1256
@steveh1256 11 месяцев назад
I’ve seen videos where people wrap the pipes where it passes through the cement. Any idea why someone would want to do that? Some use cardboard, see some use tar. Thanks
@tehapu7358
@tehapu7358 11 месяцев назад
So the pipe can expand and contract a bit without snapping. It's not 'locked' in.
@plumbinginjamaica5381
@plumbinginjamaica5381 10 месяцев назад
Check out Plumbing in Jamaica
@BevPyfer
@BevPyfer 3 месяца назад
Watching this while 💩 and seeing what will happen when I flush the toilet 🚽. Great job btw!!!" - Plumbing at its finest! 😂
@FlipNasty1
@FlipNasty1 5 месяцев назад
The combo is nothing more than a wye and a street 45°... what state are you in btw? You should be using cpvc/corzan (grey pipe) ... for all of your groundworks Charlotte abs... 3"and 2" I gotta give you props tho you're definitely a tradesmen and a craftsman
@gst4043
@gst4043 2 месяца назад
Why they dont use gravel for bed pipe Puerto Rico if you don't put gravel under they don't pass inspection
@jerryboral6105
@jerryboral6105 8 месяцев назад
Shuwaya shuokol Saduiqe
@paulgarcia458
@paulgarcia458 10 месяцев назад
Maybe do the math for the offsets, you can draw on the cardboard box your offset n get you lengths exactly where you what you want them
@articairrefrigeration9142
@articairrefrigeration9142 6 месяцев назад
Plumbing code does not allow that clean out tee to be used in a horizontal line only vertical
@xTaterxx
@xTaterxx 10 месяцев назад
So how bad is it if my plumber didn't add a vent anywhere in my slab for a 1 bed 1 bath home on a slab?
@j-rad8315
@j-rad8315 9 месяцев назад
Well.... it’s not good but if everything is draining good without gurgling then your fine. Not much you can do about it now anyways.
@merdock1108
@merdock1108 6 месяцев назад
Most licensed professional plumbers will use a string block for wall dimensions, and fittings will be wye's with st 45. Also, the sewer exiting building is 4" with a clean out within 5ft of the outside wall. Also, the main vent shall be 3" with horizontal run, not at the same plain as the drain portion. WI requires a 5psi test for 20 minutes documented for inspection, leaving all fittings exposed for udc inspection.
@JTTTTx
@JTTTTx Год назад
Most codes require a 2” for all sinks. The trap arm will be 1 1/2 , but not the underground lines. Also, get the reamer/ deburing tool- way faster and better.
@tehapu7358
@tehapu7358 11 месяцев назад
I'm thinkin' lavs are only one unit and I think you can get away with inch and a half. Could be wrong..
@JTTTTx
@JTTTTx 11 месяцев назад
@@tehapu7358 When I said sink, I should have clarified that I meant kitchen, sculary (sp), etc. - fixtures with 1 1/2 tailpieces or 2” lever drains- lavatories have an 1 1/4 tailpiece and are 1 fixture unit. Pro tip- there’s no “ getting away “ with anything here, it’s either code compliant or wrong, sorry.
@raymondkingwood9003
@raymondkingwood9003 Год назад
I'm in Wash DC area and been doing plumbing for 15 + yrs and very seen plumbing put in a Concrete Wall , when that leaks that concrete is going to deteriorate that pipe. What plumbing Area you in?
@MisterThinko
@MisterThinko Год назад
we do it before USA was USA in Europe.
Далее
MacBook Air Японский Прикол!
00:42
Просмотров 107 тыс.
Rough in plumbing basics for under a slab.
8:08
Просмотров 309 тыс.
Concrete Slab Preparation | Plumbing Ep12.2 Part 2/3
17:50
DIY Concrete Foundation for a Room Addition or ADU
19:41
ПОКУПКА ТЕЛЕФОНА С АВИТО?🤭
1:00
Тайна голубого озера😱
0:35
Просмотров 8 млн
ПРОБУЮ ОКРОШКУ СО ВСЕМ!🫣
0:57
Просмотров 1,3 млн
Falling For the Can-Am Maverick R...
0:17
Просмотров 6 млн