this delta vfd el inverter with speed settings uses an internal potentiometer to make it easy to adjust the motor speed and whoever can.
user parameters 0002-0003
basic parameters 0100-0102-0105-0106-0109-0110
mentod parameters 0200-0202
0200 frequency command set 04 internal potentiometer
0201 operation command set 02 cable terminals
and input wire terminals m11-m13 - dcm
_________________________________________________
watch other videos
how to set Inverter lsig 5a.delta hitachi. danposs. power fleck. sneiders. telemecanic. mitsubishi. toshiba. frenic mini. altivars. yaskawa. omron etc
__________________________________________________
RU-vid chanel @Abay tea
subscribe yes. Hope it is useful
#settinginverter #inverter